T60076-SL Invari TempAssure Thermostatic Two Handle Valve Trim

Product Specifications

  • Model: T60 / T75 Series T60P/T75P Series T66T Series
  • Part Number: 109508

Product Usage Instructions

Installation and Adjustment

1. Before installation, read all instructions provided in the
manual.

2. The installer must place the required labels on the water
heater and other specified locations.

3. Set the temperature adjustment knob to ensure safe maximum
temperature.

Cartridge Installation

  1. Turn off water supplies before starting the installation
    process.
  2. Remove bonnet nut and test cap from the body.
  3. If applicable, remove the plasterguard from the body.
  4. Ensure the cartridge is positioned correctly with the H marking
    on the hot inlet side.
  5. Insert the cartridge into the valve body, making sure tubes and
    O-rings are properly seated.
  6. Ensure the keys on the body are fully engaged with the slots in
    the body.

Frequently Asked Questions (FAQ)

Q: What should I do if I notice changes in water
temperature?

A: Changes in water temperature due to seasonal variations or
other factors may require adjusting the temperature setting on the
water heater. Follow the provided instructions for adjusting the
temperature knob to control the water temperature.

Q: Can I install a shut-off device on the valve outlets?

A: It is not recommended to install a shut-off device on either
outlet of the valve as it can interfere with the valve’s ability to
balance hot and cold water pressures, potentially causing
issues.

“`

IMPORTANT DOCUMENTS ENCLOSED CAUTION: To reduce the risk of injury due to hot water burns, make sure the enclosed labels are applied where specified on the label.
DOCUMENTOS IMPORTANTES INCLUIDOS AVISO: Para reducir el riesgo de lesión por quemaduras de agua caliente, asegúrese que las etiquetas incluidas se han aplicado donde se ha especificado en la etiqueta.
DOCUMENTS IMPORTANTS À L’INTÉRIEUR MISE EN GARDE : Pour réduire le risque d’ébouillantage, veuillez apposer les étiquettes fournies aux endroits indiqués sur celles-ci.

NOTICE TO INSTALLER: Place this label on the water heater next to the temperature adjustment knob.
WARNING: This series of tub/shower valves does not adjust automatically for changes in temperature at the hot water heater or inlet. If the temperature setting of the hot water heater or inlet is changed, the setting on these valves must be adjusted manually! Failure to re-adjust the valve may result in hot water burns or extreme cold resulting from variations in line pressure (such as when a dishwasher or washing machine is in use while you are taking a shower). After installation, verify that the temperature knob on the valve is set so that changes in line pressure or temperature do not result in uncomfortable water temperature changes. If the temperature setting of the hot water heater or inlet is changed after installation of the valve, the setting of the temperature knob also must be changed! Consult the installation instruction sheet for instructions on how to make this setting, or call us at 1-877-345-BRIZO.
AVISO AL INSTALADOR: Coloque esta etiqueta en el calentador de agua al lado de la perilla que ajusta la temperatura.
AVISO: Esta serie de válvulas para bañeras/regaderas no se ajusta automáticamente a los cambios de temperatura en el calentador de agua o del agua de entrada. ¡Si el ajuste de temperatura del calentado del agua caliente o del agua de entrada, el ajuste en estas válvulas debe ajustarse manualmente! El no reajustar la válvula puede resultar en quemaduras por agua caliente o temperaturas de agua extremadamente frías resultando en variaciones de presión y temperatura (como cuando el fregador de platos o la lavadora están funcionando mientras que se baña). Después de la instalación, verifique que la perilla para el control de la temperatura en la válvula está ajustada para que cambios de presión y de temperatura en la línea no resulten en cambios de temperatura del agua incómodos. Si el ajuste de la temperatura del calentador de agua o de la entrada de agua se cambia después de la instalación de la válvula, la perilla que ajuste ¡la temperatura también se debe cambiar! Consulte con su hoja de instrucciones de instalación para saber como se ajusta o cambia el ajuste o llámenos al 1-877-345-BRIZO.
AVIS À L’INSTALLATEUR : Placez cette étiquette sur le chauffeeau, près du bouton de réglage de température.
AVERTISSEMENT: La soupape de robinet de baignoire ou de douche de cette série ne se règle pas automatiquement en fonction des changements de température de l’eau chaude au chauffe-eau ou de l’eau d’alimentation. En cas de modification du réglage de température du chauffe-eau ou de la température de l’eau d’alimentation, le réglage de ces soupapes doit être modifié manuellement! Si le réglage de la soupape n’est pas modifié, le robinet pourra permettre l’écoulement d’eau très chaude susceptible de causer l’ébouillantage ou d’eau très froide, sous l’effet des variations de pression et de température dans la tuyauterie d’alimentation (lorsque la douche est utilisée en même temps que le lave-vaisselle ou la machine à laver, par exemple). Après l’installation, assurez-vous que le bouton de température sur la soupape est réglé de manière que les fluctuations de pression et de température dans la tuyauterie d’alimentation n’entraînent pas de changements de température de l’eau inconfortables. En cas de modification du réglage de température du chauffe-eau ou de la température de l’eau d’alimentation après l’installation de la soupape, le réglage du bouton de température doit être modifié! Pour régler le bouton de température, consultez la feuille d’instructions d’installation ou appelez-nous au 1-877-345-BRIZO.

NOTICE TO INSTALLER: Place this label close to the valve where the owner will see it, such as inside the door of a cabinet or vanity.
WARNING:
Water temperature changes due to seasonal or other inlet variations, such as changing the setting on the hot water heater may require adjustment of the temperature knob on your tub/shower valve to ensure a safe maximum temperature. This valve series does not automatically adjust for inlet temperature changes. If changes occur and you are not sure how to make the necessary temperature knob adjustments, please consult the installation instruction sheet provided with this valve or call 1-877-345-BRIZO. This valve is designed to reduce the risk of injury due to inlet pressure or temperature changes, commonly caused by dishwashers, washing machines, toilets and the like. It may not provide protection from hot water burns when there is a failure of other temperature controlling devices elsewhere in the plumbing system. After making the necessary adjustments please fill in the information below. This valve/system has been set by the person listed below to help ensure a safe maximum temperature. Any change in the setting may raise the temperature of the water coming out of the shower or bath above the limit considered safe and could lead to hot water burns. If this label has not been completed, you should verify that the temperature knob has been properly adjusted to suit your individual installation. The installation instruction sheet supplied with the valve provides information on how to make this setting.

AVISO AL INSTALADOR: Coloque esta etiqueta cerca de la válvula

donde el propietario la pueda ver, tal como dentro de la puerta del

gabinete o el tocador.

AVISO:

Los cambios de temperatura del agua por variaciones estacionales u otras variaciones en

el agua de entrada, como cambiando el ajuste en el calentador de agua pueden requerir el

ajuste de la perilla para el control de la temperatura de su unidad bañera/regadera para ayudar

a asegurar una temperatura máxima segura. Este válvulas no se ajusta automáticamente a

cambios de temperatura en el agua de admisión. Si los cambios ocurren y usted no está seguro

como hacer los ajustes necesarios con la perilla para controlar la temperatura, por favor

consulte la hoja de instrucciones de instalación proporcionada con esta válvula o llámenos al

1-877-345-BRIZO. Esta válvula está diseñada para reducir el riesgo de lesión por cambios de

temperatura del agua que entra o por los cambios de presión del agua que comúnmente son

causados por los usos simultáneos de fregadoras de platos, lavadoras, sanitarios y aparatos

similares. Pueda no proporcionar protección de quemaduras por el agua caliente cuando

hay una falla de otros mecanismos que controlan la temperatura del agua en otro sitio del

sistema de plomería. Después de hacer los ajustes necesarios, por favor escriba la información

a continuación. Esta válvula/sistema ha sido ajustada por la persona indicada a continuación para

ayudar a asegurar una temperatura máxima segura. Cualquier cambio al ajuste puede aumentar

la temperatura del agua que sale de la ducha o el baño sobre el límite considerado seguro

y puede resultar en quemaduras por el agua caliente. Si esta etiqueta no se a llenado, debe

verificar si la perilla para el control de la temperatura hay sido correctamente ajustada para al

gusto de su instalación individual. La hoja de instrucciones de instalación proporcionada con las

válvulas le suministra información sobre como hacer esto.

AVIS À L’INSTALLATEUR : Placez cette étiquette près de la soupape à un endroit où le propriétaire pourra la voir, du côté intérieur de la porte de l’armoire ou du meuble par exemple.
AVERTISSEMENT:
La température de l’eau peut varier en raison des changements de saison, d’une modification du réglage du chauffe-eau ou d’autres changements. Par conséquent, un réglage du bouton de température de votre soupape de douche ou de baignoire peut s’imposer pour que la température maximale de l’eau demeure sécuritaire. Les soupapes de cette série ne s’ajustent pas automatiquement aux changements de température de l’eau d’alimentation. Si des changements vous obligent à régler le bouton de température et vous n’êtes pas certain de la marche à suivre, veuillez consulter le feuillet d’instructions fourni avec la soupape ou appeler au 1-877-345-BRIZO. Cette soupape est conçue pour réduire les risques de blessures causées par des changements de la température ou de la pression de l’eau d’alimentation habituellement causés par le lave-vaisselle, la machine à laver, une toilette ou un autre appareil qui consomme de l’eau. Elle peut ne pas assurer de protection contre l’ébouillantage en cas de défectuosité d’un autre dispositif de régulation de la température dans la tuyauterie. Après avoir effectué le réglage nécessaire, veuillez inscrire l’information requise ci-dessous. La personne dont le nom figure ci-dessous a réglé cette soupape pour qu’elle puisse maintenir une température maximale sécuritaire. Toute modification du réglage peut entraîner une élévation de la température de l’eau s’écoulant par la douche ou dans la baignoire au delà de la limite considérée sécuritaire, ce qui pourrait causer un ébouillantage. Si cette étiquette n’a pas été remplie, vous devriez vous assurer que le bouton de température a été réglé en fonction des caractéristiques de votre installation. Le feuillet d’instruction fourni avec la soupape indique la marche à suivre pour effectuer le réglage.

T60 / T75 Series T60P/T75P Series

T66T Series

TO BE FILLED OUT BY THE INSTALLER / PARA SER LLENADO POR EL INSTALADOR / A REMPLIR PAR L’INSTALLATEUR:
BY/POR/PAR _______________ COMPANY/COMPANIA/COMPAGNIE ________________
DATE/FECHA/LE ___________ PHONE/TELÉFONO/TELÉPHONE ____________________

T60 / T75 Series T60P/T75P Series

T66T Series

109508

MultiChoice® Thermostatic Valve Trim
T600_______ T602_______ T604_______
Register Online www.brizo.com/customer-support/product-registration
To reference replacement parts and access additional technical documents and product info, visit www.brizo.com

?

1-877-345-BRIZO! (2749) www.brizo.com/customer-support

Read all instructions prior to installation.
! CAUTION
Failure to read these instructions prior to installation may result in personal injury, property damage, or product failure. Manufacturer assumes no responsibility for product failure due to improper installation.

You may need:

3/32″

CAUTION: This system/device must be set by the installer to ensure safe, maximum temperature. Any change in the setting may raise the discharge temperature above the limit considered safe and may lead to hot water burns.
NOTICE TO INSTALLER: CAUTION!­As the installer of this valve, it is your responsibility to properly INSTALL and ADJUST this valve per the instructions given. This valve does not automatically adjust for inlet temperature changes, therefore, someone must make the necessary temperature knob adjustments at the time of installation and further adjustments may be necessary due to seasonal water temperature change. YOU MUST inform the owner/user of this requirement by following the instructions. If you or the owner/user are unsure how to properly make these adjustments, please refer to page 7 and if still uncertain, call us at
1-877-345-BRIZO (2749).
After installation and adjustment, you must affix your name, company name and the date you adjusted the temperature knob to the caution label

provided and apply or attach the label to the back side of the closest cabinet door and the warning label to the water heater. Leave this Instruction Sheet for the owner’s/user’s reference.
WARNING: This thermostatic bath valve is designed to minimize the effects of outlet water temperature changes due to inlet pressure and temperature changes, commonly caused by dishwashers, washing machines, toilets and the like. It may not provide protection from hot water burns when there is a failure of other temperature controlling devices elsewhere in the plumbing system, if the temperature knob is not properly set or if the hot water temperature is changed after the settings are made or if the water inlet changes due to seasonal changes.
WARNING: Do not install a shut-off device on either outlet of this valve. When this type of device shuts off the water flow, it can defeat the ability of the valve to balance the hot and cold water pressures.

109508 Rev. B

1

04/19/2022

1 Cartridge Installation

A.

B.

3

4 2
1

3 2

4 1
4

Turn off water supplies. Remove bonnet nut (1) and test cap (2) from the body. If this is not
a thin wall mounting, the entire plasterguard (3)
may be removed. If screen (4) is in place, remove
before installing cartridge.

Rotate the cartridge (1) so the H (2) is on the hot inlet side of the valve. Insert cartridge into valve body as shown. Make sure the cartridge tubes and O-rings (3) are properly seated in holes at the base of the body. Ensure the keys on the body are fully engaged with the slots in the body (4).

C.

Back to back Installation

1
Slide bonnet nut (1) over the cartridge and thread onto the body. Hand tighten securely.

2 Normal Installation (changes not required) Reverse Installation
3

Cold

1

Hot

For back to back or reverse installations (hot on right and cold on left): Rotate cartridge (1) so the word “UP” (2) appears on the bottom. Install the cartridge making sure that the keys are fully engaged with the slots in the brass body (see step B). Slide bonnet nut (3) over the cartridge and thread onto the body. Hand tighten securely.

3

109508 Rev. B

2 Valve Trim Installation (See page 5 & 6 for Siderna® valve trim installation.)

A.

B.

2 2

1
Slide O-ring (1) over cartridge and the bonnet nut (2). The O-ring, which acts as a spacer to steady the sleeve, should rest behind the bonnet nut.
Note: Depending on the location of the valve within the wall and wall thickness, an optional extension kit (RP74785) can provide an additional 1 3/4″ of wall thickness.
C1. 2

1 If your model requires a spacer (1), install it into sleeve (2). Slide the sleeve over the cartridge, body and O-ring. Ensure sleeve is properly positioned over the front of cartridge.
C2.

1 3

6
5 7 9

8

Secure the escutcheon (1) to the bracket (2) with

8

the 2 screws provided (3). Do not overtighten

escutcheon screws.

109508 Rev. B

Install bracket (5) over the cartridge body using the 2 screws (6) provided. Install escutcheon (7) by placing it over the bracket as shown and rotating it to lock the tabs (8). Secure the escutcheon to the bracket using set screw (9).
4

D.

3
2 1

4 5

E.
9
6
8 7

D. Slide trim ring (1) over the cartridge and sleeve and into the escutcheon. Install volume control handle base (2) with lever to the right as shown (3). Install set screw (4) or (5) followed by the handle lever (6) or (7).
E. On most models, lever should point downward to 6 o’clock position. Install set screw (8) into handle (9). Push handle onto valve cartridge and tighten set screw to secure handle.
Note: Some models include set screw covers for volume control handle that should also be installed.

2 Siderna® Valve Trim Installation (T60080, T60280 & T60480)

B.

8

34

A.

7 2

6

1

5

4

Remove plaster guard (1) from rough (2).
Note: Depending on the location of the valve within the wall and wall thickness, an optional extension kit (RP82245) can provide an additional 1 3/4″ of wall thickness.

7 3

Using supplied Allen wrench, install both antirotational pins (3) into holes (4) in the valve body. USE CARE TO NOT DROP PINS BEHIND THE WALL. It is important that the rough be mounted in the wall as level as possible because of the square shape of this product. Slide trim sleeve (5) over the cartridge and bonnet aligning the two legs (6) of the sleeve over the anti-rotational pins (3). If the trim is not square, you can try removing a pin and holding the sleeve secure with the two set screws (7) provided. Make sure the sleeve is pushed all the way back so the legs of the sleeve rest against the valve body. The set screws (7) should be in a position where they hit just behind the bonnet nut (8). Tighten set screws (7).

5

109508 Rev. B

2 Siderna® Valve Trim Installation (T60080, T60280 & T60480)

C.

10

9

9

D.
11

10 11
1/8″
(3 mm) 11

10 10
11

Assemble the two mounting sleeves (9) and two mounting plates (10). Slide the mounting plate assemblies over the trim sleeve so that the tabs/ plates (10) are at the top and bottom of the trim sleeve, as shown. Thread screws (11) into mounting plates just enough to assemble the two sides together. Slide the mounting plates back against the wall and finish tightening the screws (11).

Using the mounting plates (10) as a guide, enlarge hole around rough so that plates can be pushed up to 1/8″ into the wall. Tighten screws (11).

E.

10

12

F.

5

14

13

15

Place the center hole of the escutcheon (12) over the trim sleeve and carefully push it back to the mounting plates (10). Magnets on the back of the escutcheon will keep it in place.

Place volume control handle (13) over valve stem (14) and onto the trim sleeve (5). Lever should point horizontally to 3 o’clock position. Secure handle with set screw (15).

109508 Rev. B

6

3 Installation and Adjustment of the Temperature Knob Failure to do so may cause injury.

2 1

5

6

4

4

Siderna®

3

13

10

1

12

14 11

Adjust temperature limit stop! Turn on water supplies; let the water run at both full hot and full cold to ensure the water is running as hot/ cold as possible. Place a thermometer in a plastic tumbler, and hold the tumbler in the water stream. Place the temperature knob (1) onto the splines (2), then rotate the temperature knob counter-clockwise until you achieve your maximum desired temperature from the outlet (not more than 120° or the lower temperature mandated by your local plumbing code). If max temperature is not achieved before limit stop (3) on temperature knob (1) meets the limit stop (4) on the volume control handle. Remove the temperature control knob (1) from splines (2). Rotate temperature control knob (1) clockwise. Place temperature control knob (1) back onto

splines (2) and continue to rotate counterclockwise until maximum desired temperature is achieved.Remove the temperature knob (1) and replace onto the splines (2), making sure that the temperature knob limit stop (3) hits against the volume handle limit stop (4) as shown. Secure the temperature knob using screw (5) and place cap (6) on knob.
For Siderna® (series T60X80) models, place temperature handle (knob) (10) onto valve stem and secure with screw (11). Ensure O-ring (12) is assembled on handle cap (13). Install handle cap by pressing it into place on top of the temperature handle (10). Secure cap by tightening screw (14) from the underside of the handle.

Cleaning and Care
Care should be given to the cleaning of this product. Although its finish is extremely durable, it can be damaged by harsh abrasives or polish. To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.

7

109508 Rev. B

60 Series Maintenance

Cannot receive more than a trickle of water: Both hot and cold supply lines must be pressurized. If only one side is pressurized, the system will not allow adequate flow of water.
Faucet leaks from showerhead: Remove the showerhead then turn the water on and off to verify if the cartridge is leaking or the showerhead is draining slowly (the showerhead may need to be cleaned if water drains slowly).
If leak persists – SHUT OFF WATER SUPPLIES Replace cartridge assembly RP47201.
Unable to set or maintain mixed water temperature: SHUT OFF WATER SUPPLIES. Remove handle assembly, trim sleeve, and bonnet nut. Check to make sure the “H” marking on the cartridge aligns with the hot inlet and the “C” marking on the cartridge aligns with the cold inlet to the valve body The thermostatic cartridge cannot function if hot and cold inlets are reversed.

Low flow: Low flow may be caused by clogged screens within the thermostatic cartridge. To clean the hot and cold screens in the cartridge, follow the steps below: 1. SHUT OFF WATER SUPPLIES. 2. Remove the handle assembly. 3. Unscrew the hex shaped portion of the cartridge
from the brass section of the cartridge. The brass section must be held securely by the flats while the hex is rotated counter-clockwise. Failure to secure the brass section while rotating the hex can result in damage to the cartridge. (See illustration below) 4. Carefully clean any debris from the screens under running water. If the debris is difficult to remove then soak the screens overnight in a 50% water and 50% vinegar solution. 5. Reassemble the cartridge. 6. Replace the handle. 7. Turn the water back on. 8. Reset the limit stop before using the valve.

Cartridge Summary Reference Sheet 17T
Brass

Hex shaped portion

Flats

Plastic

Order RP47201 to Replace Cartridge.

109508 Rev. B

8

Documents / Resources

BRIZO T60076-SL Invari TempAssure Thermostatic Two Handle Valve Trim [pdf] Instruction Manual
T60076-SL, T60076-PN, T60076-SL Invari TempAssure Thermostatic Two Handle Valve Trim, T60076-SL, Invari TempAssure Thermostatic Two Handle Valve Trim, Thermostatic Two Handle Valve Trim, Handle Valve Trim, Valve Trim, Trim

References

Leave a comment

Your email address will not be published. Required fields are marked *