BRIZO logoBRIZO BWQ1001012 Tankless Reverse Osmosis SystemPRISTIVE™
TANKLESS REVERSE
OSMOSIS SYSTEM

BWQ1001012 Tankless Reverse Osmosis System

BRIZO BWQ1001012 Tankless Reverse Osmosis System - partsBRIZO BWQ1001012 Tankless Reverse Osmosis System - overviewBrizo Kitchen & Bath Company reserves the right (1) to make changes in specifications and materials, and (2) to change or discontinue models, both without notice or obligation. Dimensions are for reference only. See current full-line price book or www.brizo.com for finish options and product availability.

STANDARD SPECIFICATIONS:

  • For cold water installation only
  • PRISTIVE™ Tankless Reverse Osmosis Water Filtration System offers 6 Stages of filtration using 3 cartridges:
    – Pre-Filter (BWQ300350) Recommended Lifespan – 3,960 gallons or 6 years* whichever comes first
    – Reverse Osmosis Filter (BWQ300102) Recommended Lifespan – 1,320 gallons or 2 years* whichever comes first
    – Carbon Filter (BWQ300202) Recommended Lifespan – 1,320 gallons or 2 years* whichever comes first
    (Filter life dependent on usage)
  • Optional 7th Stage of filtration using the remineralizer cartridge (BWQ300300) available for enhanced taste and pH balance
  • Key Specifications:
    – Feed Water Pressure: 20-80 PSI (0.14-0.6 MPa)
    – Feed Water Temperature: 41-100˚F (5-38˚C)
    – Daily Production Rate: 800 GPD (3028 L/day)
    – Rated Capacity: 1320 gallons (5000 Liters)
    – Rated Filtered Water Flow Rate: 0.56 GPM (2.10 L/min)
    – System Recovery Rating: 74%
  • Certified reduction of more than 90 contaminants from drinking water when tested against NSF standards, including: lead, total PFAS, arsenic, bacteria, chlorine, chromium, copper, TDS, mercury, microplastics, pharmaceuticals, and heavy metals
  • Tankless under sink installation and compact design
  • 2.5 : 1 Filtered-to-waste ratio
  • Integrated filter life tracking and leak detection
  • Requires 120VAC power supply outlet
  • Recommended installation with a Brizo Reverse Osmosis Beverage Faucet with integrated airgap
  • For specific performance claims refer to the Performance Data Sheet section (page 2 and 3)
  • Refer to the installation manual for more specific installation and electrical requirements

WARRANTY

  • This Brizo® reverse osmosis system is warranted to the original consumer purchaser or commercial user, as applicable, to be free from defects in material and workmanship for the applicable period specified below:
    – Reverse Osmosis Machine and Components: Five (5) years from the date the product was received by the original consumer purchaser or their authorized representative (installation contractor, etc.)
    – Pre-Filter, Filter Cartridge and Remineralizer: Thirty (30) days from the date that the product is received by the original purchaser or their authorized representative (installation contractor, etc.)
  • Please go to www.brizo.com for the complete details of our limited warranty.

BRIZO BWQ1001012 Tankless Reverse Osmosis System - symbolCOMPLIES WITH:
This system has been certified by IAPMO R&T against:
ASSE 1086, NSF/ANSI 372, 42, 53, 58, 401, and Protocol P231 for the reduction of substances for specific performance claims as verified and substantiated by test data. Refer to the Performance Data Sheet for more information.
PERFORMANCE DATA SHEET PRISTI VE™ TANKLESS REVERSE OSMOSI S SYSTEM*

PERFORMANCE DATASHEETPRISTIVE™TANKLESS REVERSE OSMOSIS SYSTEM*
Model Replacement Operating Pressure Range Operating Temperature Range Recovery
Rating**
Rated Flow Daily Production (DPR) Rated Capacity
BWQ1001012 BWQ300102 Reverse Osmosis Filter Cartridge BWQ300202 Carbon Filter Cartridge 20 – 80 PSI
(0.14 – 0.6 Mpa)
41 – 100 ˚ F
(5 – 38 ˚ C)
≥ 74% 0.56 GPM
(2.10L/min)
800 GPD
(3028 L/day)
1320 Gallons (5000 L)
This system has been tested accordingto NSF/ANSI 42, 53, 58 and 401 for reduction of the substances listed below. The concentration of the indicated substances in water enteringthe system was reduced to a concentration less than or equal to the permissible limit for water leavingthe system, as specified in NSF/ANSI 42, 53, 58 and 401.

*While test ing was performed under st andard laborat ory conditions, actual performance may vary.
**Recovery Ra ting means the percent age of the influent water to the membrane por tion of the system that is avai lable to the user as RO treat ed water when the syst em is operat ed without a st orage tank or when the st orage tank is bypassed.

Applies To Applicable Standard Substance Influent Challenge Concentration Maximum Permissible Product Water Concentration Minimum Permissible % Reduction Average Product Water Concentration Average Product Contaminant % Reduction
BWQ300202 NSF/ANSI 42 chloraminea 3.0 ± 10% mg/L mg/L ≥ 80% 0.13 mg/L 95.6%
chlorineb 2.0 ± 10% mg/L mg/L ≥ 50% 0.09 mg/L 95.6%
particulate, Class I particles 0.5 to <1 μm >10,000 particles/mL ≥ 85% 96.5%
NSF/ANSI53 per- and polyfluoroalkyl substances (PFAS)c
total PFASd,e 2.16 ± 20% μg/L 0.02 μg/L 0.006 μg/L 99.7%
chloroform (chemical surrogate for VOC) 0.300 ± 30% mg/L mg/L 95.0% 0.0032 μg/L 98.9%
NSF/ANSI 401 atenolol 200 ± 20% ng/L 30 ng/L 1.0 ng/L 99.5%
Bisphenol A(BPA) 2000 ± 20% ng/L 300 ng/L 92.3 ng/L 95.5%
carbamazepine 1400 ± 20% ng/L 200 ng/L 10.0 ng/L 99.3%
DEET(diethyltoluamide) 1400 ± 20% ng/L 200 ng/L 10.0 ng/L 99.3%
estrone 140 ± 20% ng/L 20 ng/L 4.0 ng/L 97.4%
ibuprofen 400 ± 20% ng/L 60 ng/L 15.4 ng/L 96.1%
linuron 140 ± 20% ng/L 20 ng/L 1.0 ng/L 99.3%
meprobamate 400 ± 20% ng/L 60 ng/L 1.3 ng/L 99.7%
metolachlor 1400 ± 20% ng/L 200 ng/L 17.8 ng/L 98.8%
microplastics, particles 0.5 to <1 μmf >10,000 particles/mL 85.0% 96.8%
naproxen 140 ± 20% ng/L 20 ng/L 4.5 ng/L 97.0%
nonylphenol 1400 ± 20% ng/L 200 ng/L 34.6 ng/L 97.6%
phenytoin 200 ± 20% ng/L 30 ng/L 9.3 ng/L 95.5%
TCPP (tris(1-chloro-2-propyl) phosphate) 5000 ± 20% ng/L 700 ng/L 29.6 ng/L 99.4%
trimethoprim 140 ± 20% ng/L 20 ng/L 1.0 ng/L 99.3%
BWQ300102 in BWQ1001012 NSF/ANSI 58 arsenic (pentavalent)g 0.30 ± 10% mg/L 0.01 mg/L 1.8 μg/L 99.4%
asbestos, fibers greater than 10 µm 107 to 108 fibers/L 99.0% 99.999%
barium 10.0 ± 10% mg/L 2 mg/L 73.2 μg/L 99.2%
cadmium 0.03 ± 10% mg/L 0.005 mg/L 1.0 μg/L 97.0%
chromium (trivalent) 0.3 ± 10% mg/L 0.1 mg/L 1.0 μg/L 99.7%
chromium (hexavalent) 0.3 ± 10% mg/L 0.1 mg/L 6.0 μg/L 98.0%
copper 3.0 ± 10% mg/L 1.3 mg/L 1.1 μg/L 99.97%
fluoride 8.0 ± 10% mg/L 1.5 mg/L 0.7 mg/L 91.1%
lead 0.15 ± 10% mg/L 0.005 mg/L 1.0 μg/L 99.3%
mercury 0.006 ± 10% mg/L 0.002 mg/L 0.1 μg/L 98.1%
nitrate (as N)h 27.0 ± 10% mg/L 10 mg/L 0.1 mg/L 99.8%
nitrate plus nitrite (both as N)h 30.0 ± 10% mg/L 10 mg/L 0.1 mg/L 99.8%
nitrite (as N)h 3.0 ± 10% mg/L 1 mg/L 0.1 mg/L 96.7%
radium 226/228 25 ± 10% pCi/L 5 pCi/L 5.0 pCi/L 80.0%
selenium 0.10 ± 10% mg/L 0.05 mg/L 4.4 μg/L 95.6%
TDSi 750 ± 40 mg/L 187 mg/L 51.5 μg/L 93.3%
per- and polyfluoroalkyl substances (PFAS)c
total PFASd,e 2.16 ± 20% μg/L 0.02 μg/L 0.01 μg/L 99.5%
turbidity 11 ± 1 NTU 0.5 NTU 0.4 NTU 96.8%
NSF bacteriaj 10000000/mL – – 99.9999% – – 99.99991%
cystj 10000000/L – – 99.9% – – 99.998%
virusj 10000000/L – – 99.99% – – 99.99987%

a. As monochloramine (measured as Cl2/ L) .
b. Reduction as calculat ed based on chlorami ne as the surrogate chemical .
e. Th is effluent value is based on the MCLs or health advisories in force in several New En gl and St at es for a total PFAS level of 0.02 μg/L.
f. Th ere is no rated capacity for mi croplast ics due to the broad variat ion in the quant ity of particulat e matter found in drinking water.
g. Th is syst em has been test ed for the treatment of water cont aining pentavalent arsenic (also known as As(V), As(+5), or arsenat e) at concent rations of 0.30 mg/L or less. Th is syst em reduces pent avalent arsenic, but may not remove ot her forms of arsenic. Th is system is to be used on water supplies cont aining a detectable free chlorine resi dual or on water supplies that have been demonstrat ed to cont ain only pent avalent arsenic. Tr eat ment with chlorami ne (combined chlorine) is not sufficient to ensure complete conversi on of trivalent arsenic to pent avalent arsenic. Pl ease see the Ar senic Facts sect ion of the Inst allation Inst ructions for furt her informat ion
h. Th is syst em is accept able for treat ment of influent concentrat ions of no more than 27 mg/L ni trat e and 3 mg/L ni trite in combinat ion measured as N and is cert ified for ni trat e / ni trite reduc tion only for water supplies with a pressure of 210 kPa (30 psig) or gr eater.
i. Th is reverse osmosi s syst em cont ains replaceable treat ment components critical for effective reduc tion of TD S. Th e product wat er shall be test ed per iodically to verify that the syst em is performing satisfactorily.
j. Th is syst em is not intended to convert wast ewat er or raw sewage into drinki ng water.
d. Th e test mi xt ure for total PFAS is made up of PFOA (500 ppt ), PFOS (1,000 ppt), PFHxS (300 ppt), PFNA (50 ppt), PFHpA (40 ppt), PFBS (260 ppt), and PFDA (10 ppt).
c. For PFAS, the indi vi dual influent tolerance is ± 30%.

Volatile Organic Chemicals (VOCs) included by surrogate testing of chloroform
Applies To Applicable Standard Chemical Drinking water regulatory level a (MCL/MAC) Influent challenge concentration b Chemical reduction percent Maximum product water concentration
BWQ300202 NSF/ANSI 53 alachlorc 0.002 mg/L 0.05 mg/L > 98 0.001 mg/L
atrazinec 0.003 mg/L 0.1 mg/L > 97 0.003 mg/L
benzenec 0.005 mg/L 0.081 mg/L > 99 0.001 mg/L
carbofuranc 0.04 mg/L 0.19 mg/L > 99 0.001 mg/L
carbon tetrachlorided 0.005 mg/L 0.078 mg/L 98 0.0018 mg/L
chlorobenzenec 0.1 mg/L 0.077 mg/L > 99 0.001 mg/L
chloropicrinc 0.015 mg/L 99 0.0002 mg/L
2,4-Dd 0.07 mg/L 0.11 mg/L 98 0.0017 mg/L
dibromochloropropane (DBCP)c 0.0002 mg/L 0.052 mg/L > 99 0.00002 mg/L
o-dichlorobenzenec 0.6 mg/L 0.08 mg/L > 99 0.001 mg/L
p-dichlorobenzenec 0.075 mg/L 0.04 mg/L > 98 0.001 mg/L
1,2-dichloroethanee 0.005 mg/L 0.088 mg/L 95 e 0.0048 mg/L
1,1-dichloroethylenec 0.007 mg/L 0.083 mg/L > 99 0.001 mg/L
cis-1,2-dichloroethylenec 0.07 mg/L 0.17 mg/L > 99 0.0005 mg/L
trans-1,2-dichloroethylenec 0.1 mg/L 0.086 mg/L > 99 0.001 mg/L
1,2-dichloropropanec 0.005 mg/L 0.08 mg/L > 99 0.001 mg/L
cis-1,3-dichloropropylenec 0.079 mg/L > 99 0.001 mg/L
dinosebd 0.007 mg/L 0.17 mg/L 99 0.0002 mg/L
endrind 0.002 mg/L 0.053 mg/L 99 0.00059 mg/L
ethylbenzenec 0.7 mg/L 0.088 mg/L > 99 0.001 mg/L
ethylene dibromide (EDB)c 0.00005 mg/L 0.044 mg/L > 99 0.00002 mg/L
haloacetonitriles (HAN)c bromochloroacetonitrilec dibromoacetonitrilec dichloroacetonitrilec trichloroacetonitrilec 0.022
0.024
0.0096
0.015
mg/L 98
98
98
98
0.0005
0.0006
0.0002
0.0003
mg/L
haloketones (HK)c 1,1-dichloro-2-propanonec 1,1,1-trichloro-2- propanonec 0.0072
0.0082
mg/L 99
96
0.0001
0.0003
mg/L
heptachlor (H-34, Heptox) 0.0004 mg/L 0.025 mg/L > 99 0.00001 mg/L
heptachlor epoxidef 0.0002 mg/L 0.0107 f mg/L 98 0.0002 mg/L
hexachlorobutadienec 0.044 mg/L > 98 0.001 mg/L
hexachlorocyclopentadienec 0.05 mg/L 0.06 mg/L > 99 0.000002 mg/L
lindanec 0.0002 mg/L 0.055 mg/L > 99 0.00001 mg/L
methoxychlorc 0.04 mg/L 0.05 mg/L > 99 0.0001 mg/L
pentachlorophenolc 0.001 mg/L 0.096 mg/L > 99 0.001 mg/L
simazinec 0.004 mg/L 0.12 mg/L > 97 0.004 mg/L
styrenec 0.1 mg/L 0.15 mg/L > 99 0.0005 mg/L
1,1,2,2-tetrachloroethanec 0.081 mg/L > 99 0.001 mg/L
tetrachloroethylenec 0.005 mg/L 0.081 mg/L > 99 0.001 mg/L
toluenec 1 mg/L 0.078 mg/L > 99 0.001 mg/L
2,4,5-TP (silvex)d 0.05 mg/L 0.27 mg/L 99 0.0016 mg/L
tribromoacetic acidc 0.042 mg/L > 98 0.001 mg/L
1,2,4-trichlorobenzenec 0.07 mg/L 0.16 mg/L > 99 0.0005 mg/L
1,1,1-trichloroethaned 0.2 mg/L 0.084 mg/L 95 0.0046 mg/L
1,1,2-trichloroethanec 0.005 mg/L 0.15 mg/L > 99 0.0005 mg/L
trichloroethylenec 0.005 mg/L 0.18 mg/L > 99 0.0010 mg/L
trihalomethanes (includes): chloroform (surrogate chemical) bromoform bromodichloromethane
chlorodibromomethane
0.08 mg/L 0.3 mg/L 95 0.015 mg/L
xylenes (total)c 10 mg/L 0.07 mg/L > 99 0.001 mg/L

a Th ese harmonized values were agreed upon by representatives of U.S. EPA and Heal th Canada for the purpose of eval uating products to the requiremen ts of this standard.
b Influent chal lenge levels are average infl uent concen trat ions determined in surrogat e qualification testing.
c Maxi mum product water level was not observed but was set at the detection limit of the an al ysis.
d Maxi mum product water level is set at a value determined in surrogat e qual ificat ion testing.
e Chem ical reduction percen t and maxi mum product water level calculat ed at chloroform 95% breakthroμgh point as determined in surrogate qual ificat ion testing.
f Th e surrogate test results for heptachlor epoxide demonstrat ed a 98% reduction. Th ese data were used to calculat e an upper occurrence concen trat ion that would produce a maxi mum product water level at the Maxi mum Contam inen t Level (MCL).

BRIZO logoBrizo Kitchen & Bath Company
55 E. 111th Street, Carmel, Indiana 46280
350 South Edgeware Road, St. Thomas, ON N5P 4L1
© 2024 Brizo Kitchen & Bath Company

Documents / Resources

BRIZO BWQ1001012 Tankless Reverse Osmosis System [pdf] Owner's Manual
BWQ1001012, BWQ1001012 Tankless Reverse Osmosis System, Tankless Reverse Osmosis System, Reverse Osmosis System, Osmosis System, System

References

Leave a comment

Your email address will not be published. Required fields are marked *