BLUEVOLUTiON FTXTM-R Perfera Wall Mounted Unit
Attractive, wall-mounted design with perfect indoor air quality down to -25°C
- Guaranteed heating capacity at low ambient temperature, down to -25°C
- Seasonal efficiency values up to A+++ in cooling and heating
- When installed close to a heating device (e.g. fireplace or oven) and the set temperature is reached, the fan keeps on running to have an even temperature throughout the whole house
- Heat boost quickly heats up your home when starting up your air conditioner. Set temperature is reached 14% faster than a regular air conditioner (pair only)
- Using electrons to trigger chemical reactions with airborne particles, the Flash Streamer breaks down allergens such as pollen and fungal allergens and removes bothersome odours providing a better, cleaner air
- Silver allergen removal and air purifying filter captures allergens such as pollen to ensure a steady supply of clean air
- Voice command via Amazon Alexa or Google Assistant to control main functions such as set point, operation mode, fan speed, etc
- Onecta app: control your indoor from any location with an app, via your local network or internet.
- 2 area motion detection sensor: air flow is sent to a zone other than where the person is located at that moment; if no people are
detected, the unit will automatically switch over to the energy-efficient setting. - 3-D air flow combines vertical and horizontal auto swing to circulate a stream of warm or cool air right to the corners of even large spaces.
- Quiet operation: down to 19dBA sound pressure level
- Sleek, unobtrusive air conditioning unit that matches European sensibilities regarding interior design
- Choosing for an R-32 product, reduces the environmental impact with 68% compared to R-410A and leads directly to lower energy consumption thanks to its high energy efficiency.
More details and final information can be found by scanning or clicking the QR codes.
FTXTM-R
RXTM-R
Efficiency data | FTXTM + RXTM | 30R + 30R | 40R + 40R | |
Cooling capacity | Min./Nom./Max. | kW | 0.70/3.00/4.50 | 0.90/4.00/5.10 |
Heating capacity | Min./Nom./Max. | kW | 0.80/3.20/6.70 | 1.20/4.00/7.20 |
Power input | Cooling Nom. | kW | 0.73 | 1.08 |
Heating Nom. | kW | 0.60 | 0.74 | |
Space cooling | Energy efficiency class | ![]() |
||
Capacity Pdesign | kW | 3.00 | 4.00 | |
SEER | 7.60 | 7.70 | ||
Annual energy consumption | kWh/a | 138 | 182 | |
Space heating (Average climate) | Energy efficiency class | ![]() |
||
Capacity Pdesign | kW | 3.00 | 3.80 | |
SCOP/A | 5.12 | 5.30 | ||
Annual energy consumption | kWh/a | 821 | 1,003 | |
Space heating (Cold Energy efficiency class | ![]() |
|||
climate) | Capacity Pdesignh | kW | 4.38 | 5.55 |
Annual energy consumption | kWh/a | 2,276 | 2,803 | |
SCOP/C | 4.04 | 4.16 | ||
Nominal efficiency | SEER | 4.10 | 3.71 | |
COP | 5.34 | 5.37 | ||
Annual energy consumption | kWh | 366 | 539 | |
Energy labeling Directive Cooling/Heating | A/A |
Indoor unit FTXTM | 30R | 40R | ||
Dimensions Unit HeightxWidthxDepth mm | 295x778x272 | 299x998x292 | ||
Weight Unit kg | 10.0 | 14.5 | ||
Air filter Type | Removable/washable | |||
Fan Air ow
rate |
Cooling Silent operation/ m³/min Low/Medium/High | 4.1/5.3/7.8/12.2 | 4.6/5.8/9.5/15.4 | |
Heating Silent operation/ m³/min
Low/Medium/High |
4.0/4.9/7.5/12.5 | 5.9/7.1/10.5/17.5 | ||
Sound power level | Cooling dBA | 60.0 | ||
Heating dBA | 61.0 | |||
Sound pressure level | Cooling Silent operation/Low/High dBA | 21.0/25.0/45.0 | 20.0/24.0/46.0 | |
Heating Silent operation/Low/High dBA | 19.0/22.0/45.0 | 19.0/22.0/46.0 | ||
Control systems Infrared remote control | ARC46 | 6A75 |
Outdoor unit | RXTM | 30R | 40R | |
Dimensions | Unit HeightxWidthxDepth | mm | 551x763x312 | |
Weight | Unit | kg | 38 | |
Sound power level | Cooling Nom. | dBA | 61.0 | |
Heating Nom. | dBA | 61.0 | ||
Sound pressure level | Cooling Nom. | dBA | 48 | |
Heating Nom. | dBA | 49 | ||
Operation range | Cooling Ambient Min.~Max. | °CDB | -10~46 | |
Heating Ambient Min.~Max. | °CWB | -25~18 | ||
Refrigerant | Type/GWP | R-32/675 | ||
Charge | kg/TCO2Eq | 1.1/0.74 | ||
Piping connections | Liquid/Gas OD | mm | 6.35/9.50 | |
Piping length OU – IU Max. | m | 20 | ||
Additional refrigerant charge | kg/m | 0.02 (for piping length exceeding 10m) | ||
Level di erence IU – OU Max. | m | 15 | ||
Power supply | Phase/Frequency/Voltage | Hz/V | 1~/50 /220-240 | |
Current – 50Hz | Maximum fuse amps (MFA) | A | 16 |
Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | See separate drawing for operation range | See separate drawing for electrical data | Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m | Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m | See separate drawings for electrical data | Contains fluorinated greenhouse gases