BLAUBERG Turbo 250 G Mixed Flow Inline Fans
Product Usage Instructions
Installation
- Choose a suitable location for the Turbo 250 G unit near the air duct.
- Ensure proper ventilation around the unit for optimal performance.
- Connect the air duct to the unit according to the specified size (125mm).
- Securely mount the unit in place using appropriate fixtures.
- Verify the power supply voltage meets the requirements (230V).
Operation
- Turn on the power supply to the Turbo 250 G unit.
- Select the desired speed setting based on your ventilation needs (2 Phases available).
- Monitor the airflow and adjust as necessary using the controls.
- Maintain ambient air temperature within the specified range for efficient operation.
Maintenance
- Regularly clean the unit and air duct to prevent dust buildup and blockages.
- Check for any unusual sounds or vibrations during operation and address promptly.
- Refer to the user manual for any specific maintenance tasks recommended by the manufacturer.
Features
Turbo 250 G
Mixed-flow inline fans
- Sound pressure level LpA at 3 m: 51
- Motor type: AC
- Control: Speed controller
- Impeller type: Mixed-flow
- Casing material: Plastik
- Installation in any position
- Cable with mains plug
- Temperature sensor
Specifications
Unit of measurement | Turbo 250 G | ||
Connected air duct size | mm | 250 | |
Speed | – | 2 | |
Phases | – | 1 | |
Minimum supply voltage | V | 230 | |
Maximum supply voltage | V | 230 | |
Power supply frequency | Hz | 50/60 | |
Rated power | W | 125 | 177 |
Unit current | A | 0.54 | 0.79 |
Maximum airflow | m3/h | 1110 | 1400 |
Rotation speed at 50hz | – | ||
Sound pressure level LpA at 3 m | dB(A) | 44 | 51 |
Weight | kg | 7.8 | |
Transported air temperature (max) | °С | 60 | |
Ambient air temperature min | °С | 0 | |
Ambient air temperature max | °С | 0 | |
Ingress protection rating | – | IPX4 | |
Ingress protection rating of the drive | – | IPX4 |
Frequency
Dimensions
ØD | ØD1 | B | H | L |
247 | 257 | 287 | 323 | 383 |
FAQ
Q: What is the maximum airflow of the Turbo 250 G?
A: The maximum airflow of the Turbo 250 G is 1400 m3/h.
Q: What is the sound pressure level at a distance of 3 meters?
A: The sound pressure level LpA at 3m is 44 dB.
Q: What is the Ingress protection rating of the drive?
A: The Ingress protection rating of the drive is IPX4.
Documents / Resources
![]() |
BLAUBERG Turbo 250 G Mixed Flow Inline Fans [pdf] Installation Guide Turbo 250 G Mixed Flow Inline Fans, Turbo 250 G, Mixed Flow Inline Fans, Flow Inline Fans, Inline Fans |