BLAUBERG Turbo 125 Mixed Flow Inline Fans
Product Usage Instructions
- Ensure the connected air duct size matches the product specifications.
- Provide an appropriate power supply within the voltage range specified.
- Securely mount the unit in a suitable location, ensuring properventilation.
- Switch on the unit and select the desired speed setting.
- Monitor the airflow and adjust settings as needed.
- Maintain ambient air temperature within the specified range for optimal performance.
Maintenance
- Regularly clean the unit and air ducts to ensure efficient operation.
- Check for any unusual sounds or vibrations during operation and address promptly.
FEATURED
Turbo 125
Mixed-flow inline fans
- Sound pressure level LpA at 3 m: 34
- Motor type: AC
- Control: Speed switch
- Impeller type: Mixed-flow
- Casing material: Plastik
- Installation in any position
- Cable with mains plug
SPECIFICATION
Unit of measurement |
Turbo 125 |
||
Connected air duct size | mm | 125 | |
Speed | – | 2 | |
Phases | – | 1 | |
Minimum supply voltage | V | 230 | |
Maximum supply voltage | V | 230 | |
Power supply frequency | Hz | 50/60 | |
Rated power | W | 25 | 29 |
Unit current | A | 0.11 | 0.13 |
Maximum airflow | m3/h | 240 | 350 |
Rotation speed at 50hz | – | ||
Sound pressure level LpA at 3 m | dB(A) | 29 | 34 |
Weight | kg | 2.15 | |
Transported air temperature (max) | °С | 60 | |
Ambient air temperature min | °С | 0 | |
Ambient air temperature max | °С | 0 | |
Ingress protection rating | – | IPX4 | |
Ingress protection rating of the drive | – | IPX4 |
Power supply frequency
Dimensions
ØD | ØD1 | B | H | L |
123 | 164 | 167 | 190 | 246 |
Ecodesign
Trademark | Blauberg | |||||
Model | Turbo 125 | |||||
Specific energy consumption (SEC) (kWh/(m2/a)) |
Cold | Average | Warm | |||
53.6 | A+ | 26.6 | B | 11.1 | E | |
Type of ventilation unit | Unidirectional | |||||
Type of drive installed | Variable speed | |||||
Type of heat recovery system | None | |||||
Maximum flow rate (m3/h) | 275 | |||||
Electric power input (W) | 29 | |||||
Reference flow rate (m3/s) | 0.053 | |||||
Reference pressure difference (Pa) | 50 | |||||
Specific power input (SPI) (W/(m3/h)) | 0.13 | |||||
Control typology | Local demand control | |||||
Maximum external leakage rates (%) | 2.7 | |||||
Declared typology | RVU UVU | |||||
Sound power level (dB(A)) | 54 | |||||
The annual electricity consumption (AEC) (kWh/a) |
Cold | Average | Warm | |||
69 | 69 | 69 | ||||
The annual heating saved (AHS) (kWh/a) |
Cold | Average | Warm | |||
5536 | 2830 | 1280 |
FAQ
Q: What is the specific energy consumption of the Turbo 125?
A: The specific energy consumption (SEC) is 53.6 kWh/(m2/a).
Q: What is the type of ventilation unit installed in the Turbo 125?
A: The Turbo 125 has a cold type of ventilation unit installed.
Q: How do I control the Turbo 125?
A: The Turbo 125 features local demand control for operation.