Specifications
- Operating System: Custom OS
- iX Developer Version: 2.52
- Scripting Capabilities: .NET CF 3.5
- User Interface: Modernized UI with improved Chart object and Component library
- Media Support: Media player, PDF viewer
- Security Features: Secure app transfer, Firewall protection, Secure remote access
- System Management: Active Directory integration, FTP support, Business integrations
- Drivers: Supports various industrial communication protocols, including OPC UA, Ethernet, Serial, CAN, SoftControl, and BACnet
Product Usage Instructions
Operating System and System Features:
The device runs on a custom OS supporting iX Developer with features like UI settings, USB and SD card support, multi-app support, firewall protection, and remote access capabilities.
iX Projects and iX Apps:
The iX Developer version 2.52 allows project conversion from previous versions and supports scripting capabilities using .NET CF 3.5.
User Interface & Usability:
The product offers a modernized IDE UI with an improved Chart object, Component library, HTML5 browser support, touch beep feature, and additional controls for enhanced usability.
Security and System Management:
Ensure system security by utilizing features like Secure app transfer, firewall protection, and system settings configuration via iX Developer. Active Directory integration and FTP support are available for system management.
X2 vs X3 – Software Comparison
- This chapter provides a comparative overview of the software features in the X2 and X3 series, highlighting differences between the X2, the first release of X3, and future X3 updates. It covers key aspects such as the operating system, security, services, iX Developer compatibility, user interface improvements, system management, industrial communication protocols, and business integrations. The chapter outlines feature availability, enhancements, and limitations in each version, helping to understand the evolution of the X3 platform and its capabilities relative to the X2 series.
NOTE
Features and specifications may change as the products evolve. Always refer to the latest documentation for up-to-date information.
Operating system and system features
| X2 | X3 – Initial release | X3 – Future updates | |
| Operating system | Beijer Shell | OS3 1.0 | OS3 X |
| Supports iX Developer | Yes | Yes | Yes |
| System settings UI | Yes | Yes | Yes |
| USB support | Yes | Yes | Yes |
| SD card support | Yes | Yes | Yes |
| Security | |||
| Secure app transfer | No | Yes | Yes |
| Secure app install from USB storage | Yes | No | Yes |
| System settings protection | No | Yes | Yes |
| Firewall (default: closed) | No | Yes | Yes |
| Security patches | No | Yes | Yes |
| Services | |||
| Multi-app support | No | iX Developer only | Yes |
| Remote access (VNC) | Yes | No | No |
| Secure remote access (HTTPS-proxied, authenticated VNC) | No | No | Yes |
| System requirements – For more information, see App System Requirements and System Requirements. | No | Yes | Yes |
iX projects and iX apps
| X2 | X3 – Initial release | X3 – Future updates | |
| iX Developer version | 2.52 | 3.0 | 3. X |
| Project conversion from previous versions | Yes | Yes | Yes |
| X2 | X3 – Initial release | X3 – Future updates | |
| Scripting capabilities | Yes | Yes | Yes |
| Latest scripting framework support | .NET CF 3.5 | .NET 8 LTS | .NET X LTS (LTS
lifecycle) |
| References assemblies | Yes | No (use NuGet instead) | No (use NuGet instead) |
| NuGet support | No | Yes | Yes |
| PC-Runtime | Yes | No | Yes |
| System settings (COM, LAN A/LAN B, power saving, SNTP) | Yes | Yes | Yes |
| User interface & usability | |||
| Modernized IDE UI | No | Yes | Yes |
| Improved Chart object | No | Yes | Yes |
| Modern Component library | No | Yes (enhanced look and feel) | Yes (enhanced look and feel) |
| Improved Trend Viewer | No | No | Yes |
| SVG support | No | No | Yes |
| GIT-friendly projects | No | No | Yes |
| HTML5 browser | No | Yes | Yes |
| Media player | Yes | No (use Web Browser object instead) | No (use Web Browser object instead) |
| PDF viewer | Yes | No (use Web Browser object instead) | No (use Web Browser object instead) |
| Picture in picture | No | Yes (in Web Browser object) | Yes (in Web Browser object) |
| QR code object | Yes | No (use NuGet instead) | No (use NuGet instead) |
| Additional controls (DLL-support) | Yes | No (use NuGet instead) | Yes |
| Touch beep | Yes | No | Yes |
| Rotate object | Yes (only for industrial PC targets) | No | Yes (only for industrial PC targets) |
| Run action | Yes | No | No |
| Security and system management | |||
| X2 | X3 – Initial release | X3 – Future updates | |
| Active Directory on-premises | No | Yes | Yes |
| Active Directory cloud solution | No | Yes | Yes |
| Active Directory Federation Services (ADFS) cloud solution | No | Yes | Yes |
| Configurable TCP ports via iX Developer | Yes | Yes | Yes |
| Services | |||
| Web server | Yes | Yes (REST
API only) |
Yes (REST
API only) |
| FTP support | Yes | No | No |
| Secure file transfer CLI (replacing FTP) | No | Yes | Yes |
| Excel report | Yes | Yes | Yes |
| Print Excel report | Yes | No | Yes |
| Remote alarm & distribution | Yes | No | Yes |
| Business integrations | |||
| OS keyboard integration | No | Yes | Yes |
| Non-Latin keyboards | Yes | No | Yes |
| Brands | Yes | No | Yes |
| Targets | |||
| HMI panels | Yes | Yes | Yes |
| Industrial PCs | Yes | No | Yes |
Drivers (industrial communication protocols)
| X2 | X3 – Initial release | X3 – Future updates | |
| Supported drivers (approximate number) | 70 | 15 | 50 |
| OPC UA | Yes | Yes | Yes |
| Secure OPC UA | No | No | Yes |
| Drivers with Ethernet support | Yes | Yes | Yes |
| Drivers with Serial support | Yes | Yes | Yes |
| Drivers with CAN support | Yes | No | Yes |
| Drivers with SoftControl support | Yes | Yes (dependent on CODESYS) | Yes |
| Drivers with BACnet support | Yes | No | TBD |
| Drivers with expansion modules support | Yes | No | No |
X2 to X3 – Transition Guide for iX Developer
Follow this transition guide to ensure a smooth and secure transition from iX Developer 2 to iX Developer 3 on Beijer Electronics X3 HMI panels.
Prerequisites
- Development PC
- X2 HMI panel
- X3 HMI panel
Instructions
- Review the Modified Features in iX Developer 3.0 chapter to understand changes and evaluate their impact on your project.
- Confirm that your driver is supported in iX Developer 3 by checking the Driver List X3 HMI Panels. If your driver is not listed here, Contact Beijer Electronics.
- Connect the X2 HMI panel to the development PC.
- If you are using an older version of iX Developer (before 2.53), follow these steps:
- Create a project backup. Refer to Back Up the Project for instructions.
- Download and install iX Developer 2.53 from the Beijer Electronics SmartStore.
- Open your project in iX Developer 2.53.
- Build the project and resolve any build errors that appear.
- Download the project to the X2 HMI panel. Refer to the Download chapter in the iX Developer 2.53 Reference Manual for download instructions.
- Verify the project functionality on the HMI panel.
- Save the project.
- Create a project backup. Refer to Back Up the Project for instructions.
- Quit iX Developer.
- Connect the X3 HMI panel to the development PC.
- Download and install iX Developer 3 from the Beijer Electronics SmartStore.
- Open your project in iX Developer 3.
IMPORTANT
When opening your project in iX Developer 3, a dialog will provide key information and recommendations for project conversion. Read this carefully and follow the instructions. - Build the project and address any build errors using the How to Resolve Transition Build Errors guide.
- Transfer the project to the X3 HMI panel. Refer to the Transfer the iX App to the HMI Panel chapter in the iX Developer 3 User Manual for transfer instructions.
- Verify the project functionality in the iX App on the HMI panel.
TIP
In some cases, when the transferred project is run on the HMI panel, the project won’t open and an Access Denied dialog appears. See Troubleshooting for information on how to solve this issue. - Save the project.
- Now your project is fully compatible with iX Developer 3.
TIP - For additional help, consult the FAQ, visit the Connected forum, or contact Beijer Electronics support.
- Now your project is fully compatible with iX Developer 3.
Modified Features in iX Developer 3.0
Some features from earlier versions are not included in iX Developer 3.0 at launch. In most cases, alternative features are available. To help you understand how these changes affect your project, the features are grouped into four transition categories:
Transition categories
- Easy = You can switch to an alternative feature with little or no effort.
- Medium = Some effort is required to switch. Review the alternatives before transition.
- Hard = Requires advanced knowledge. Carefully review the alternative before transition.
- Wait = No alternative is currently available. If your project depends on this feature, wait for a future update.
Review each modified feature in the table below. Identify which changes affect your project, and decide whether to make the transition now or wait for a future version.
| Transition category | Modified feature | Description | Alternative |
| Easy | Media player object | Removed | Use the Web Browser Object instead. |
| PDF viewer object | |||
| SMS and Printer functionality | Removed in version 2.52. | Save to USB, SD card, or HMI panel. Then use e-mail if required. | |
| System settings | In iX Developer 3, you cannot configure
system settings directly as in previous versions. Instead, you define System Requirements that are evaluated and then reserved by the OS3 operating system. If the requirements cannot be fulfilled, the iX App will not start. |
Define the System Requirements. | |
| USB transfer | App transfer via USB is no longer supported. | Use Ethernet transfer instead. See Transfer the iX App to the HMI Panel. | |
| Target rotate | Not available for X3 HMI panels. | Set Target rotate to
0 (landscape orientation) instead. Follow these steps: 1. Open the project in iX Developer 2.52. 2. Navigate to Project > Settings. 3. Under Display/ Target, set Target rotate to 0. 4. Click OK to save. |
| Transition category | Modified feature | Description | Alternative |
| Virtual keyboards for non-Latin languages | Will be included in iX Developer 3.1. | Use a Latin virtual keyboard or an external keyboard for now. | |
| Medium | QR-code object | Removed due to outdated libraries. | Use NuGet packages. See NuGet Packages. |
| Hard | DLL
compatibility (third-party controls) |
DLL-based support has been removed. | Use NuGet packages. See NuGet Packages. |
| Web server features | • JavaScript SDK is deprecated.
• REST APIs are not fully backward compatible. • HTTPS is required. • Local port 7001 is fixed. |
For more information, see Web Server. | |
| Run action | Removed due to security and architectural reasons. | Use Scripts instead. | |
| FTP | Removed due to security and architectural reasons. | Use Transfer Client CLI instead. | |
| Wait | Watchdog | Not available. | Alternative will be introduced in future OS3 updates. |
| PC runtime | Not available. | Will be included in future iX Developer updates. |
| Transition category | Modified feature | Description | Alternative |
| Support for certain system tags | The following system tags are not yet implemented:
• ImageVersion (2x: Windows CE Image Version) • Internal Temperature • Flash Memory Life Time Used • Flash Memory EOL Info • Power LED Blink Frequency • Power LED Blue Intensity • Power LED Green Intensity • Power LED Red Intensity • LedCount |
Will be included in future iX Developer updates. | |
| VNC | Removed due to security concerns. | Secure VNC will be introduced in future OS3 updates. |
How to Resolve Transition Build Errors
| Build error | Action |
| CS0246: The type or namespace name “SQLiteConnection” could not be found (are you missing a using directive or assemble refrence?) | See Update SQLite Code. |
| CS0246: The type or namespace name “SQLiteException” could not be found (are you missing a using directive or assemble refrence?) | |
| CS0246: The type or namespace name “SQLiteDataAdapter” could not be found (are you missing a using directive or assemble refrence?) | |
| Control System.Windows.Forms.DataGrid on screen Screen5 is not supported. Double-click to suppress build error. | See Replace Unsupported DataGridView Control |
| Control System.Windows.Forms.StatusBar on screen Screen5 is not supported. Double-click to suppress build error. | |
| Control System.Windows.Forms.ToolBar on screen Screen5 is not supported. Double-click to suppress build error. | |
| Ftp is no longer supported due to security considerations. Double-click to suppress build error. | See Modified Features in iX Developer 3.0. |
| Key beep is no longer supported. Double-click to suppress build error. | See Modified Features in iX Developer 3.0. |
| Password for project transfer is no longer needed but a password for the project zip archive can be used. Double-click to suppress build error. | See Transfer the iX App to the HMI Panel. |
| Pin code is no longer supported. Double-click to suppress build error. | The Service Menu in iX Runtime in iX Developer 2, where the PIN code was used, has moved to OS3. Refer to the OS3 User Guide for more information. |
| Printing is no longer supported. Double-click to suppress build error. | See Modified Features in iX Developer 3.0. |
| System settings are replaced with System Requirements, and must be manually migrated. Please consult the documentation before suppressing the build error. Double- click to show settings. | See Migrate System Settings from iX2 to iX3. |
| The keyboard culture used is unsupported and US will be used instead. Support for more cultures will be added in the future. Double- click to suppress build error. | See Modified Features in iX Developer 3.0. |
| Build error | Action |
| The report DatabaseReport is in .xls format, please save it as .xlsx instead. Any SQL queries in your report also need to be moved to the Queries section. See Reference Manual for more information. | See Migrate Reports from iX2 to iX3. |
| The report Report1 is in .xls format, please save it as .xlsx instead. Any SQL queries in your report also need to be moved to the Queries section. See Reference Manual for more information. | See Migrate Reports from iX2 to iX3. |
| Topmost window is no longer supported. Double-click to suppress build error. | |
| Unsupported parameter action ‘Printer’ used by Print Screen action in screen: Screen1.
Replace it with ‘File’ parameter action. |
|
| VNC is no longer supported due to security reasons. A potential replacement will be included in a future release as part of
OS3 platform. Double-click to suppress build error. |
See Modified Features in iX Developer 3.0. |
| Virtual keyboard is now always enabled. Double-click to suppress build error. | |
| Watchdog is no longer supported. Double- click to suppress build error. | See Modified Features in iX Developer 3.0. |
Migrate System Settings from iX2 to iX3
When converting an iX Developer project from iX2 to iX3, you need to manually migrate the system settings.
Instructions
- After opening and running the project in iX Developer 3.0 for the first time, the following Build Error appears: System settings are replaced with System Requirements, and must be manually migrated. Please consult the documentation before suppressing the build error. Double-click to show settings.
- Double-click the build error message to open the System Requirements. Alternatively, navigate to Project > Settings > System Requirements.
- Click Import old System Settings to import the settings from the iX Developer 2.52 project.
- If some settings are not imported, click Add to manually configure them.
Replace Unsupported DataGridView Control
To fix the build error:
Control System.Windows.Forms.DataGrid on screen Screen5 is not supported. Double-click to suppress build error. you must replace the old DataGridView control with a new one.
Instructions
- Go to Home and expand the Objects group
- Click Add Control.
- Deselect the DataGridView and click OK.
- Reload the project
- Open Add Control again and add a DataGridView.
- Update the script to reference the new DataGridView.
Migrate Reports from iX2 to iX3
- Open the Project Folder and navigate to Reports > Template and open the .xls template files.
- In Excel, select File > Save As and change the file extensions to .xlsx.
- In Excel, check if there is sheet named <#Config>.
- If not, go to step 7.
- If yes, continue with step 4:
- Open the project in iX Developer 3.
- Go to the Reports Configuration Page and select the Queries tab.
- Add all the queries from the <#Config> sheet manually, as shown in the example screenshot.

- In iX Developer 3, go to the Reports Configuration Page and select the Reports tab.
- Replace the existing .xls files with the updated .xlsx files in the Reports list.
Update SQLite Code
This guide explains how to update code from System.Data.SQLite to Microsoft.Data.Sqlite.
Original Code: System.Data.SQLite
The example below uses System.Data.SQLite to retrieve data from a table:
- // System.Data.SQLite
- public DataTable Select(string tablename)
- {
- DataTable dt = new DataTable();

Key steps
- Connect to the database (ConnectToDataBase).
- Use SQLiteDataAdapter to execute the query and fill the DataTable.
- Handle errors with a try-catch block.
- Disconnect from the database after use.
Updated Code: Microsoft.Data.Sqlite
This example uses Microsoft.Data.SQLite for the same operation:


Key updates
- Use string interpolation ($””) to build SQL queries.
- Replace SQLiteDataAdapter with SQLiteCommand.
- Use ExecuteReader and dt.Load(reader) to load data.
- Manage resources using statements.
Troubleshooting
| Problem | Reason | Solution |
| Access Denied | OS3
environment |
Ensure all necessary changes are completed before deploying your application in an OS3-enabled environment. Refer to X2 to |
| dialog | is not | X3 – Transition Guide for iX Developer. |
| appears | prepared. | |
| when opening the app on the HMI
panel. |
||
| File paths in scripts are not updated. | Modify your existing iX scripts to accommodate the updated file access permissions. Writing to the installation folder of your application is no longer permitted. | |
| Save locations are incorrect. | If your scripts save files to the installation folder, update them to use a writable location. Use the predefined variable
GlobalsBase.Environment.Application.CommonApplicationData to |
|
| retrieve the correct path. |
TIP
For additional support, visit the Connected forum or contact Beijer Electronics support.
- Head Office Beijer Electronics AB Box 426
- 201 24 Malmö, Sweden
- www.beijerelectronics.com/+46 / +46 40 358600
FAQs
Are iX3 scripts compatible with iX2?
How do I script with FlexCel in iX3?
How do I convert existing DLLs (e.g., OpenNetCF, FlexCel) to NuGet in iX3?
How do I install NuGet packages in iX3?
Does iX3 support SVG vector graphics?
Why do I get warnings about Opacity, Radius, or Rotation?
Can the Web Server in iX3 read/write tags?
Can I change the Web Server port in iX3?
Why can’t I ping the HMI panel?
Can I save my username and password during project transfer?
Do I need to buy a new license for iX3?
What is the difference between Test Mode and Production Mode?
Documents / Resources
![]() | X3 Human Machine Interface |
References
- Human Verificationconnected.beijerelectronics.com
- Beijer Electronics SmartStoresmartstore.beijerelectronics.com
- Contact us - Beijer Electronicswww.beijerelectronics.com
- iX Developer 3 Driver Listwww.beijerelectronics.com
- Ribbon Tabswww.beijerelectronics.com
- Aboutwww.beijerelectronics.com
- Functionswww.beijerelectronics.com
- NuGet Packageswww.beijerelectronics.com
- NuGet Packageswww.beijerelectronics.com
- Objectswww.beijerelectronics.com
- User Manualmanual.tools