Lutron Athena Clear Connect Gateway – Type X

Product Overview

The Athena Clear Connect Gateway – Type X is a ceiling-mounted device that integrates Clear Connect – Type X devices, including Ketra loads, with Lutron's existing Clear Connect – Type A and QS devices through the wired Athena Edge Processor. It enables compatible Lutron control systems to communicate with up to 50 wireless, Clear Connect – Type X devices, including Ketra Intelligent Light Sources.

Features

Specifications

Regulatory Approvals

PoE Power

Environment

System Communications and Capacity

ESD Protection

Surge Protection

Power Failure

Mounting

Wiring

Dimensions

All dimensions are shown in inches (mm).

Front View: Diameter 4.04 in (102.67 mm)

Side View: Height 1.17 in (29.82 mm)

Back View: Features status and program indicators, power input, Ethernet port, and FCC/IC information.

Mounting Details

Recess/Wall-Mount

Ceiling thickness: Minimum 0.30 in (7.62 mm) to Maximum 1.20 in (30.48 mm). Requires a 3.25 in to 3.5 in (83 mm to 89 mm) opening.

Surface-Mount

Use appropriate mud ring for ceiling tile thickness. Use mud ring with hole spacing as shown in the diagram (mud ring not included with any models).

Note: Both the recess-mount and surface-mount adaptors ship with the Athena Clear Connect Gateway – Type X units.

System Riser Diagram

Illustrates the connection of QP5, Q-POE-PNL, and the Athena Clear Connect Gateway – Type X within a system, connected to a building network.

Note: Refer to the IT Guide at www.lutron.com/ITguide for more information on networking requirements.

Range Diagram

All Clear Connect – Type X devices must be within 71 ft (22 m) of the Athena Clear Connect Gateway – Type X.

Notes:

The diagram shows the coverage area of the Athena Clear Connect Gateway – Type X, indicating a maximum range of 71 ft (22 m).

Choose a Location to Install

Mount the gateway centrally in relation to other Clear Connect – Type X devices. A minimum of two or more Clear Connect – Type X devices must be within 25 ft (7.6 m) of the gateway. Each Clear Connect – Type X device should have two or more non-battery powered Type X devices within 25 ft (7.6 m) of another compatible Clear Connect – Type X device.

The diagram illustrates placement within a floor plan, showing optimal distances for Clear Connect – Type X devices and Wireless Access Points.

Fixture Legend:

Athena Security Statement

Lutron prioritizes cybersecurity with a proactive approach, monitoring the threat landscape and continuously enhancing systems and processes. This approach is called "Secure Lifecycle". Key aspects include:

Security features incorporated into product designs include recommendations from NIST and aim to meet secure lifecycle protections. Examples include:

For questions or to report a vulnerability, contact Lutron's 24/7 Technical Support at 1.844.LUTRON1 or support@lutron.com.

Models: Gateway Control Equipment

File Info : application/pdf, 7 Pages, 516.55KB

PDF preview unavailable. Download the PDF instead.

3691144 ENG

References

Adobe PDF Library 15.0 Adobe InDesign 16.0 (Windows)

Related Documents

Preview Lutron Athena Q-TOUCH5 Touchscreen Controller Datasheet
Detailed datasheet for the Lutron Athena Q-TOUCH5 touchscreen controller, outlining features, specifications, compatibility with Lutron Athena systems, installation guidelines, and wiring requirements for commercial lighting and shade control.
Preview Lutron Athena Q-TOUCH5 Touchscreen: Specifiche e Caratteristiche
Scopri il touchscreen Lutron Athena Q-TOUCH5, un controller digitale a parete per la gestione avanzata di illuminazione e tende. Include specifiche tecniche, compatibilità, installazione e diagrammi di sistema.
Preview Athena Clear Connect Gateway Type X Installation Instructions
Comprehensive installation guide for the Athena Clear Connect Gateway Type X, covering setup, component identification, troubleshooting, and regulatory information. Includes details on compatible Ketra lighting fixtures and system requirements.
Preview Lutron Athena Wireless Processor Installation Guide
Step-by-step instructions for installing the Lutron Athena Wireless Processor / Clear Connect - Type X Gateway, including component lists, tools required, installation procedures, LED diagnostics, and troubleshooting.
Preview Lutron Athena Q-TOUCH5 Touchscreen Digital Wall Control Specifications
Detailed technical specifications for the Lutron Athena Q-TOUCH5 touchscreen digital wall control, designed for comprehensive lighting and shade management in commercial environments.
Preview Lutron Athena Q-TOUCH5 Touchscreen Datasheet
Detailed specifications and features of the Lutron Athena Q-TOUCH5 wall-mounted digital touchscreen, designed for controlling Athena lighting loads and shades in commercial applications. Learn about its compatibility, power requirements, mounting options, and regulatory approvals.
Preview Écran tactile Athena Q-TOUCH5 - Spécifications techniques Lutron
Découvrez l'écran tactile Athena Q-TOUCH5 de Lutron, un système de commande mural numérique pour la gestion des éclairages et stores connectés. Ce document détaille ses caractéristiques, compatibilité, dimensions et options de montage pour les installations commerciales.
Preview Lutron Athena Q-TOUCH5 Touchscreen Spezifikationen
Detaillierte Spezifikationen für den Lutron Athena Q-TOUCH5 wandmontierten Touchscreen, eine Steuerung für Athena-vernetzte Beleuchtung und Rollos mit umfassender Benutzererfahrung und flexibler Steuerung für einzelne Räume oder mehrere Bereiche.