ELKO EL-430

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Кіраўніцтва па эксплуатацыі

Уводзіны

This manual provides detailed instructions for the proper use, setup, and maintenance of your ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and home use to measure blood pressure non-invasively.

Што ў скрынцы

ELKO EL-430 Sphygmomanometer components and packaging

Image showing the ELKO EL-430 Sphygmomanometer packaging and its main components: the high precision gauge, BP bulb with valve, and special design cotton cuff.

Upon opening the package, verify that all components are present and undamaged. The standard package for the ELKO EL-430 includes:

Асноўныя характарыстыкі

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Image of the ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer, showing the large clock-face gauge, the black cotton cuff, and the inflation bulb.

Настройка

Before taking a measurement, ensure the device is properly assembled and positioned. The EL-430 is a clock/desk type unit, designed for stable placement during use.

  1. Распакуйце кампаненты: Carefully remove the sphygmomanometer, cuff, and inflation bulb from the packaging.
  2. Connect Cuff and Bulb: Ensure the cuff and inflation bulb are securely connected to the gauge via their respective tubes. The dual-tube bladder should be correctly attached.
  3. Размясціце прыладу: Place the main gauge unit on a stable, flat surface, such as a desk or table, at approximately heart level. The integrated basket can be used to keep the cuff and bulb organized.
  4. Падрыхтоўка пацыента: The patient should be seated comfortably with their arm resting on a flat surface, palm facing upwards. Ensure the arm is relaxed and at heart level. Avoid talking or moving during the measurement.

Operating Instructions: Measurement Procedures

Blood Pressure Measurement Procedures

Image illustrating the four key steps for blood pressure measurement: stethoscope placement, cuff inflation, listening for Korotkoff sounds, and controlled deflation.

Для дакладнага вымярэння артэрыяльнага ціску выканайце наступныя дзеянні:

  1. Cuff Placement and Stethoscope Positioning: Wrap the cuff firmly around the upper arm, ensuring it is snug but not too tight. The lower edge of the cuff should be about 1 inch (2-3 cm) above the elbow joint. Place the stethoscope head over the main artery (brachial artery), which is typically found on the inner side of the arm, underneath the artery mark of the cuff.
  2. Інфляцыя: With the air release valve completely closed, press the inflation bulb repeatedly and continue pumping until the gauge reads a value 20-30 mmHg above your normal systolic blood pressure. If you do not know your normal systolic pressure, inflate to approximately 180-200 mmHg.
  3. Listening and Recording Systolic Pressure: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second. Listen carefully through the stethoscope. The first distinct, rhythmic sound you hear (Korotkoff sound) indicates the systolic pressure (the upper number). Note the reading on the gauge at this exact moment.
  4. Listening and Recording Diastolic Pressure: Continue to slowly deflate the cuff. The point at which the Korotkoff sounds completely disappear indicates the дыясталічны ціск (the lower number). Note this reading on the gauge. If the sounds become muffled but do not disappear, the muffled sound point can be considered the diastolic pressure.

Разуменне паказчыкаў артэрыяльнага ціску

Blood Pressure Chart and Reading Precautions

Image displaying a blood pressure chart categorizing readings (Normal, Elevated, High Blood Pressure Stages 1 & 2, Hypertensive Crisis) and a list of conditions under which a reading should not be attempted.

Refer to the chart below for general blood pressure categories. Consult a healthcare professional for interpretation of your readings and personalized advice.

Blood Pressure Chart (mmHg)
Катэгорыя артэрыяльнага ціскуSystolic (upper number)Diastolic (lower number)
НармальныМенш за 120Менш за 80
Прыўзняты120 - 129 ггМенш за 80
Высокае крывяны ціск (гіпертанія) Stagе 1130 - 139 гг80 - 89 гг
Высокае крывяны ціск (гіпертанія) Stagе 2140 або вышэй90 або вышэй
Hypertensive Crisis (consult your doctor immediately)Higher Than 180Higher Than 120

DO NOT ATTEMPT A READING...

  1. Within 1 hour of food intake.
  2. Immediately after a tea, coffee, or a smoke.
  3. Within 20 minutes of taking a bath.
  4. While talking or moving your hand/fingers.
  5. When climate is very cold.
  6. When bladder is full or you feel like discharging urine.

Тэхнічнае абслугоўванне і догляд

Proper maintenance ensures the longevity and accuracy of your sphygmomanometer.

Ліквідацыю непаладак

If you encounter issues with your ELKO EL-430, refer to the following common problems and solutions:

Тэхнічныя характарыстыкі

СпецыфікацыяДэталь
Нумар мадэліEL-430
Тып дысплеяАналаг
Дыяпазон вымярэнняў0 - 300 mmHg
Дакладнасць+/- 3 mmHg
Тып абшэўкіLarge Cotton Cuff with Velcro Fasteners
Уключаныя кампанентыCuff, Gauge, Inflation Bulb with Valve
Вага прадмета600 г
Памеры прадукту (Д х Ш х У)14L x 14W x 18Th Centimeters
ВытворцаAnita Industries
Краіна паходжанняІндыя
Дата першай даступнасці12 лютага 2024 г

Гарантыя і падтрымка

For warranty information, technical support, or service inquiries regarding your ELKO EL-430 Sphygmomanometer, please contact the manufacturer directly.

Кантактная інфармацыя вытворцы:
Anita Industries
New Delhi, India
электронная пошта: info@elkoindia.com
Тэлефон: +91 9911129201

Please have your model number (EL-430) and date of purchase available when contacting support.

Звязаныя дакументы - EL-430

прэview Інструкцыя па заканчэнні тэрміну службы разеткі ELKO RS16 TV/SAT/R і кіраўніцтва па ўтылізацыі
Падрабязнае кіраўніцтва па ўтылізацыі разеткі ELKO RS16 TV/SAT/R пасля заканчэння тэрміну службы, уключаючы падрабязную інфармацыю аб прадукце, кампанентах і магчымасці перапрацоўкі ў адпаведнасці з дырэктывай WEEE.
прэview Кіраўніцтва карыстальніка для разумнага радыятарнага тэрмастата ELKO
Падрабязнае кіраўніцтва карыстальніка для разумнага радыятарнага тэрмастата ELKO, якое ахоплівае ўвод у эксплуатацыю, наладу, канфігурацыю, выкарыстанне, ліквідацыю непаладак і тэхнічныя характарыстыкі. Даведайцеся, як падключыць, кіраваць і аўтаматызаваць сістэму ацяплення для камфорту і энергаэфектыўнасці.
прэview Разетка ELKO Schuko з зараднай прыладай USB 3.0 A - Кіраўніцтва па ўсталёўцы і выкарыстанні
Comprehensive guide for the ELKO Schuko socket outlet featuring dual USB 3.0 A charging ports (Type A and Type C). Includes essential safety warnings, detailed technical specifications, installation steps, and usage instructions for electrical professionals and end-users.
прэview Інструкцыя па ўсталёўцы разеткі ELKO Plus / ELKO RS16 DCL
Поўнае кіраўніцтва па ўсталёўцы разетак ELKO Plus і ELKO RS16 DCL. Уключае важныя папярэджанні аб бяспецы, пакрокавыя працэдуры мантажу, дэмантажу вечка, падлучэння штэкера, тэхнічныя характарыстыкі і правільную інфармацыю па ўтылізацыі. Неабходна для кваліфікаваных электрыкаў.
прэview Кіраўніцтва карыстальніка разумнага радыятарнага тэрмастата ELKO - Устаноўка, налада і эксплуатацыя
Поўнае кіраўніцтва карыстальніка для разумнага радыятарнага тэрмастата ELKO (EKO09765), якое ахоплівае ўстаноўку, спалучэнне, канфігурацыю, штодзённае выкарыстанне, планаванне, аўтаматызацыю, ліквідацыю непаладак і тэхнічныя характарыстыкі.
прэview ELKO Smart Radiatortermostat Brukerhåndbok
Падрабязная інструкцыя па тэхніцы тэрмастата ELKO Smart Radiator, якая змяшчае функцыю, тэхналогію, чыстку, аўтаматыку, тэхніку і тэхнічныя характарыстыкі для аптымальнай эксплуатацыі.