BAYROL TECHNIK TECHNIK Automatic Smart and Easy Box
Technical Data
- Smart&Easy Box
- Data transformer pool lighting 12 V~, 100 VA
- Filter pump power supply Thermal-magnetic circuit breaker 4-6.3 A
- Pump switch ON / OFF / AUTO switch on the front
- Protection class IP 66
- Dimensions (W x H x D) 260 x 400 x 140 mm
- Smart&Easy Control Module
- Relay connection 4 NO outputs (OUT 1/2/3/4)
- Relay connection data max. 4A / 230VAC / 24VDC
- Frequency-controlled pump (VSP) connection 4 digitale Relais:
- 3 NO: Eco, Normal, High
- 1 NO/NC: Stop
- VSP connection data max. 50mA / 35 VDC / 150 mW
- Power supply 240 V~, 50/60 Hz
- Max. power consumption 5 W
- Dimensions, incl. antenna (W x H x D) 70 x 90 x 80 mm
Wiring diagram
Danger warning
electric access to authorised personnel only!
All cables must be of type U1000R2V
EN Description
- Power supply 230 V + Ground (L, N, PE)
The power supply line must be protected by a 30mA earth leakage circuit breaker (RCD)! - 230 V filtration pump
- 230 V slave dosing pump (Automatic Cl-pH)
- Pool lighting 12 V 100 VA
- Socket for Automatic Salt or Cl-pH
- 16 A circuit breaker for socket (5), S&E Control Module and 230 V slave dosing pump (3)
- 2 A circuit breaker for pool lighting (4)
- Thermal-magnetic circuit breaker for filter pump (2)
Setting the thermal-magnetic circuit breaker
- The magneto-thermal circuit breaker must be set according to the filter pump used, using the adjustment
- knob on the front panel.
- Electrical data / Environment
- Neutral system: TT system
- System overvoltage category: 3
- Operating temperature: -5 °C to +35 °C
- Maximum installation altitude: 2000 m
- Maximum relative humidity:100 % at 25 °C, 50 % at 35 °C
Safety instructions
- The persons who install and commission the product must be qualified for this type of work: a licensed/certified electrician or a qualified technician for swimming pool maintenance.
- Please observe the applicable accident prevention regulations.
- Before carrying out any work, the power supply to the product must be disconnected and locked.
- Only install the control box in the technical room or indoors.
- The switch box must be connected in accordance with the diagram in these instructions.
- Do not connect more products than are normally provided on the switch box. If you connect several cables with different cross-sections to one terminal, this can lead to a fire hazard.
- Feed the cables of the devices to be connected to the control box through the cable glands attached to the control box.
FAQ
- Q: How do I reset the Smart&Easy Control Module?
A: To reset the module, locate the reset button on the device and press it for a few seconds until the module restarts. - Q: Can the Smart&Easy Box be used outdoors?
A: Yes, the Smart&Easy Box has an IP66 protection rating, making it suitable for outdoor use.
Documents / Resources
![]() |
BAYROL TECHNIK TECHNIK Automatic Smart and Easy Box [pdf] Instruction Manual TECHNIK Automatic Smart and Easy Box, TECHNIK, Automatic Smart and Easy Box, Smart and Easy Box, Easy Box |