BANNER S15S IO Link Temperature User Guide

S15S IO-Link Temperature, Humidity, and Dew Point Sensor – IO-Link Data
Reference Guide

BANNER A - 1

Original Instructions
p/n: 242289 Rev. A
13-Aug-24
© Banner Engineering Corp. All rights reserved.

Chapter 1 IO-Link Data Map

This document refers to the following IODD file: Banner_Engineering-S15S-TH-KQ-20240615-IODD1.1.xml. The IODD file and support files can be found on www.bannerengineering.com under the download section of the product family page.

Communication Parameters

The following communication parameters are used.

Parameter Value
IO-Link revision V1.1
Process Data In length 120 bits
Process Data Out length N/A
Bit Rate 38400 bps
Minimum cycle time 4 ms
Device ID 663553 (0x0a2001)
Port class A
SIO mode No
Smart Sensor Profile Yes
Block parameterization Yes
Data Storage Yes

Chapter 2 IO-Link Process Data In (Device to Master)

Process Data Mode (1): Smart Sensor Fahrenheit
Subindex Name Number of Bits
1 Temperature Value 16
2 Temperature Scale 8
3 Temperature Over Threshold 1
4 Temperature Under Threshold 1
5 Dew Point Value 16
6 Dew Point Scale 8
7 Dew Point Over Threshold 1
8 Dew Point Under Threshold 1
9 Relative Humidity Value 16
10 Relative Humidity Scale 8
11 Relative Humidity Over Threshold 1
12 Relative Humidity Under Threshold 1
Octet 0
Subindex
Bit offset 119 118 117 116 115 114 113 112
Value 0 0 0 0 0 0 0 1
Octet 1
Subindex
Bit offset 111 110 109 108 107 106 105 104
Value 1 1 1 1 1 1 0 1
Octet 2
Subindex
Bit offset 103 102 101 100 99 98 97 96
Value 1 1 1 1 1 1 1 0
Octet 3
Subindex 1 1 1 1 1 1 1 1
Bit offset 95 94 93 92 91 90 89 88
Value 0 0 0 0 1 1 1 1
Octet 4
Subindex 1 1 1 1 1 1 1 1
Bit offset 87 86 85 84 83 82 81 80
Value 1 1 1 1 1 1 1 1
Octet 5
Subindex 2 2 2 2 2 2 2 2
Bit offset 79 78 77 76 75 74 73 72
Value 1 1 1 1 1 1 1 0
Octet 6
Subindex 3 4
Bit offset 71 70 69 68 67 66 65 64
Value 1 1 1 1 1 1 1 0
Octet 7
Subindex 5 5 5 5 5 5 5 5
Bit offset 63 62 61 60 59 58 57 56
Value 0 0 0 1 0 0 1 1
Octet 8
Subindex 5 5 5 5 5 5 5 5
Bit offset 55 54 53 52 51 50 49 48
Value 1 1 1 0 1 1 0 0
Octet 9
Subindex 6 6 6 6 6 6 6 6
Bit offset 47 46 45 44 43 42 41 40
Value 1 1 1 1 1 1 1 0
Octet 10
Subindex 7 8
Bit offset 39 38 37 36 35 34 33 32
Value 1 1 1 1 1 1 0 0
Octet 11
Subindex 9 9 9 9 9 9 9 9
Bit offset 31 30 29 28 27 26 25 24
Value 1 1 1 1 1 1 1 0
Octet 12
Subindex 9 9 9 9 9 9 9 9
Bit offset 23 22 21 20 19 18 17 16
Value 1 1 0 1 0 0 0 0
Octet 13
Subindex 10 10 10 10 10 10 10 10
Bit offset 15 14 13 12 11 10 9 8
Value 1 1 1 1 1 1 1 0
Octet 14
Subindex 11 12
Bit offset 7 6 5 4 3 2 1 0
Value 1 1 1 1 1 1 0 0
Examples Based Upon The Values Above

Temperature

Temperature Value = 4095
Temperature Scale = -2
Scaled Temperature Value = 40.95 °F
Temperature Over Threshold = True
Temperature Under Threshold = False

Dew Point

Dew Point Value = 5100
Dew Point Scale = -2
Scaled Dew Point Value = 51.00 °F
Dew Point Over Threshold = False
Dew Point Under Threshold = False

Relative Humidity

Relative Humidity Value = 6523
Relative Humidity Scale = -2
Scaled Relative Humidity Value = 65.23%
Relative Humidity Over Threshold = False
Relative Humidity Under Threshold = False

Process Data Mode (2): Smart Sensor Celsius
Subindex Name Number of Bits
1 Temperature Value 16
2 Temperature Scale 8
3 Temperature Over Threshold 1
4 Temperature Under Threshold 1
5 Dew Point Value 16
6 Dew Point Scale 8
7 Dew Point Over Threshold 1
8 Dew Point Under Threshold 1
9 Relative Humidity Value 16
10 Relative Humidity Scale 8
11 Relative Humidity Over Threshold 1
12 Relative Humidity Under Threshold 1
Octet 0
Subindex
Bit offset 119 118 117 116 115 114 113 112
Value 0 0 0 0 0 0 0 1
Octet 1
Subindex
Bit offset 111 110 109 108 107 106 105 104
Value 1 1 1 1 1 1 0 1
Octet 2
Subindex
Bit offset 103 102 101 100 99 98 97 96
Value 1 1 1 1 1 1 1 0
Octet 3
Subindex 1 1 1 1 1 1 1 1
Bit offset 95 94 93 92 91 90 89 88
Value 1 1 0 0 0 0 1 1
Octet 4
Subindex 1 1 1 1 1 1 1 1
Bit offset 87 86 85 84 83 82 81 80
Value 0 1 1 1 0 0 1 0
Octet 5
Subindex 2 2 2 2 2 2 2 2
Bit offset 79 78 77 76 75 74 73 72
Value 1 1 1 1 1 1 1 0
Octet 6
Subindex 3 4
Bit offset 71 70 69 68 67 66 65 64
Value 1 1 1 1 1 1 1 0
Octet 7
Subindex 5 5 5 5 5 5 5 5
Bit offset 63 62 61 60 59 58 57 56
Value 1 0 1 0 1 1 1 1
Octet 8
Subindex 5 5 5 5 5 5 5 5
Bit offset 55 54 53 52 51 50 49 48
Value 1 0 0 0 0 1 0 0
Octet 9
Subindex 6 6 6 6 6 6 6 6
Bit offset 47 46 45 44 43 42 41 40
Value 1 1 1 1 1 1 1 0
Octet 10
Subindex 7 8
Bit offset 39 38 37 36 35 34 33 32
Value 1 1 1 1 1 1 0 0
Octet 11
Subindex 9 9 9 9 9 9 9 9
Bit offset 31 30 29 28 27 26 25 24
Value 1 1 1 1 1 1 1 0
Octet 12
Subindex 9 9 9 9 9 9 9 9
Bit offset 23 22 21 20 19 18 17 16
Value 1 1 0 1 0 0 0 0
Octet 13
Subindex 10 10 10 10 10 10 10 10
Bit offset 15 14 13 12 11 10 9 8
Value 1 1 1 1 1 1 1 0
Octet 14
Subindex 11 12
Bit offset 7 6 5 4 3 2 1 0
Value 1 1 1 1 1 1 0 0
Examples Based Upon The Values Above

Temperature

Temperature Value = -1552
Temperature Scale = -2
Scaled Temperature Value = -15.52 °C
Temperature Over Threshold = True
Temperature Under Threshold = False

Dew Point

Dew Point Value = 913
Dew Point Scale = -2
Scaled Dew Point Value = 9.13 °C
Dew Point Over Threshold = False
Dew Point Under Threshold = False

Relative Humidity

Relative Humidity Value = 3513
Relative Humidity Scale = -2
Scaled Relative Humidity Value = 35.13%
Relative Humidity Over Threshold = False
Relative Humidity Under Threshold = False

Process Data Mode (3): Floating Point Fahrenheit
Subindex Name Number of Bits
1 Temperature Value 32
2 Temperature Over Threshold 1
3 Temperature Under Threshold 1
4 Dew Point Value 32
5 Dew Point Over Threshold 1
6 Dew Point Under Threshold 1
7 Relative Humidity Value 32
8 Relative Humidity Over Threshold 1
9 Relative Humidity Under Threshold 1
Octet 0
Subindex 1 1 1 1 1 1 1 1
Bit offset 119 118 117 116 115 114 113 112
Value 0 1 0 0 0 0 0 0
Octet 1
Subindex 1 1 1 1 1 1 1 1
Bit offset 111 110 109 108 107 106 105 104
Value 1 0 0 0 0 0 1 1
Octet 2
Subindex 1 1 1 1 1 1 1 1
Bit offset 103 102 101 100 99 98 97 96
Value 0 0 0 0 1 0 1 0
Octet 3
Subindex 1 1 1 1 1 1 1 1
Bit offset 95 94 93 92 91 90 89 88
Value 0 0 1 1 1 1 0 1
Octet 4
Subindex 2 3
Bit offset 87 86 85 84 83 82 81 80
Value 0 0 0 0 0 0 0 1
Octet 5
Subindex 4 4 4 4 4 4 4 4
Bit offset 79 78 77 76 75 74 73 72
Value 0 1 0 0 0 0 0 0
Octet 6
Subindex 4 4 4 4 4 4 4 4
Bit offset 71 70 69 68 67 66 65 64
Value 1 0 1 0 0 0 1 1
Octet 7
Subindex 4 4 4 4 4 4 4 4
Bit offset 63 62 61 60 59 58 57 56
Value 0 0 1 1 0 0 1 1
Octet 8
Subindex 4 4 4 4 4 4 4 4
Bit offset 55 54 53 52 51 50 49 48
Value 0 0 1 1 0 0 1 1
Octet 9
Subindex 5 6
Bit offset 47 46 45 44 43 42 41 40
Value 1 1 1 1 1 1 0 1
Octet 10
Subindex 7 7 7 7 7 7 7 7
Bit offset 39 38 37 36 35 34 33 32
Value 0 1 0 0 0 0 1 0
Octet 11
Subindex 7 7 7 7 7 7 7 7
Bit offset 31 30 29 28 27 26 25 24
Value 1 0 0 0 0 0 1 0
Octet 12
Subindex 7 7 7 7 7 7 7 7
Bit offset 23 22 21 20 19 18 17 16
Value 0 1 1 1 0 1 1 0
Octet 13
Subindex 7 7 7 7 7 7 7 7
Bit offset 15 14 13 12 11 10 9 8
Value 1 1 0 0 1 0 0 1
Octet 14
Subindex 8 9
Bit offset 7 6 5 4 3 2 1 0
Value 1 1 1 1 1 1 1 0
Examples Based Upon The Values Above

Temperature

Temperature Value = 40.95 °F
Temperature Over Threshold = True
Temperature Under Threshold = False

Dew Point

Dew Point Value = 51.00 °F
Dew Point Over Threshold = False
Dew Point Under Threshold = False

Relative Humidity

Relative Humidity Value = 65.23%
Relative Humidity Over Threshold = False
Relative Humidity Under Threshold = False

Process Data Mode (4): Floating Point Celsius
Subindex Name Number of Bits
1 Temperature Value 32
2 Temperature Over Threshold 1
3 Temperature Under Threshold 1
4 Dew Point Value 32
5 Dew Point Over Threshold 1
6 Dew Point Under Threshold 1
7 Relative Humidity Value 32
8 Relative Humidity Over Threshold 1
9 Relative Humidity Under Threshold 1
Octet 0
Subindex 1 1 1 1 1 1 1 1
Bit offset 119 118 117 116 115 114 113 112
Value 1 1 0 0 0 0 0 1
Octet 1
Subindex 1 1 1 1 1 1 1 1
Bit offset 111 110 109 108 107 106 105 104
Value 0 1 1 1 1 0 0 0
Octet 2
Subindex 1 1 1 1 1 1 1 1
Bit offset 103 102 101 100 99 98 97 96
Value 0 0 0 0 1 0 0 0
Octet 3
Subindex 1 1 1 1 1 1 1 1
Bit offset 95 94 93 92 91 90 89 88
Value 0 0 1 1 0 0 0 1
Octet 4
Subindex 2 3
Bit offset 87 86 85 84 83 82 81 80
Value 0 0 0 0 0 0 0 1
Octet 5
Subindex 4 4 4 4 4 4 4 4
Bit offset 79 78 77 76 75 74 73 72
Value 1 1 0 0 0 0 0 1
Octet 6
Subindex 4 4 4 4 4 4 4 4
Bit offset 71 70 69 68 67 66 65 64
Value 1 0 1 0 0 1 0 0
Octet 7
Subindex 4 4 4 4 4 4 4 4
Bit offset 63 62 61 60 59 58 57 56
Value 1 1 0 0 1 1 0 0
Octet 8
Subindex 4 4 4 4 4 4 4 4
Bit offset 55 54 53 52 51 50 49 48
Value 1 1 0 0 1 1 0 1
Octet 9
Subindex 5 6
Bit offset 47 46 45 44 43 42 41 40
Value 1 1 1 1 1 1 0 1
Octet 10
Subindex 7 7 7 7 7 7 7 7
Bit offset 39 38 37 36 35 34 33 32
Value 0 1 0 0 0 0 1 0
Octet 11
Subindex 7 7 7 7 7 7 7 7
Bit offset 31 30 29 28 27 26 25 24
Value 1 0 0 0 0 0 1 0
Octet 12
Subindex 7 7 7 7 7 7 7 7
Bit offset 23 22 21 20 19 18 17 16
Value 0 1 1 1 0 1 1 0
Octet 13
Subindex 7 7 7 7 7 7 7 7
Bit offset 15 14 13 12 11 10 9 8
Value 1 1 0 0 1 0 0 1
Octet 14
Subindex 8 9
Bit offset 7 6 5 4 3 2 1 0
Value 1 1 1 1 1 1 1 0
Examples Based Upon The Values Above

Temperature

Temperature Value = -15.52 °C
Temperature Over Threshold = True
Temperature Under Threshold = False

Dew Point

Dew Point Value = 9.13 °C
Dew Point Over Threshold = False
Dew Point Under Threshold = False

Relative Humidity

Relative Humidity Value = 35.13%
Relative Humidity Over Threshold = False
Relative Humidity Under Threshold = False

Chapter 3 IO-Link Process Data Out (Master to Device)

Not applicable.

Chapter 4 Parameters Set Using IO-Link

These parameters can be read from and/or written to an S15S-TH-KQ sensor. Also included is information about whether the variable in question is saved during Data Storage and whether the variable came from the IO-Link Smart Sensor Profile.

Unlike Process Data In, which is transmitted from the IO-Link device to the IO-Link master cyclically, these parameters are read or written a cyclically as needed.

Index Subindex Name Length Value Range Default Access Rights Data Storage? Smart Sensor Profile
0 1-16 Direct Parameter Page 1
(incl. Vendor ID & Device ID)
RO
16 Vendor Name string Banner Engineering Corporation RO
17 Vendor Text string More Sensors. More Solutions. RO
18 Product Name string S15S-TH-KQ RO
19 Product ID string S15S-TH-KQ RO
20 Product Text string S15S-TH-KQ RO Y
21 Serial Number RO
22 Hardware Versopm RO
23 Firmware Version V1.1 RO Y
24 App Specific Tag (user defined) More Sensors. More Solutions.  RW Y Y
25 Function Tag More Sensors. More Solutions.  RW Y Y
26 Location Tag More Sensors. More Solutions.  RW Y Y
32 Error Count 16-bit Uinteger RO
36 Device Status 8-bit integer 0 = Device is OK
1 = Maintainance required
2 = Out of specification
3 = Functional check
4 = Failure
5..255 Reserved
RO
37 Detailed Device Status Array[4] of 3-
octet
RO
69 All-Time Run Time
69 1 Run counter (0.25hr) 32-bit Uinteger 0..2147483647 RO Y
70 Resettable Run Time
70 1 Run counter (0.25hr) 32-bit Uinteger 0..2147483647 0 RW
71 Alarm Configuration
71 1 Temperature Low Threshold Float32 32 RW Y
71 2 Temperature High Threshold Float32 120 RW Y
71 3 Relative Humidity Low Threshold Float32 0 RW Y
71 4 Relative Humidity High Threshold Float32 100 RW Y
71 5 Dew Point Low Threshold Float32 32 RW Y
71 6 Dew Point High Threshold Float32 120 RW Y
71 7 Temperature On Delay Float32 0 RW Y
71 8 Temperature Off Delay Float32 0 RW Y
71 9 Relative Humidity On Delay Float32 0 RW Y
71 10 Relative Humidity Off Delay Float32 0 RW Y
71 11 Dew Point On Delay Float32 0 RW Y
71 12 Dew Point Off Delay Float32 0 RW Y
72 Alarm Counter
72 1 Temperature Low Counter Float32 0 RW Y
72 2 Temperature High Counter Float32 0 RW Y
72 3 Relative Humidity Low Counter Float32 0 RW Y
72 4 Relative Humidity High Counter Float32 0 RW Y
72 5 Dew Point Low Counter Float32 0 RW Y
72 6 Dew Point High Counter Float32 0 RW Y
80 Process Data Mode
80 1 Defines the formatting of the Process Data 8-bit Uinteger 1 = Smart Sensor Profile, Fahrenheit
2 = Smart Sensor Profile, Celsius
3 = Floating Point, Fahrenheit
4 = Floating Point, Celsius
1 RW Y
81 Wire Mode
81 1 Output Configuration 8-bit Uinteger 0 = BannerBus, 1 = Discrete Output 0 RW Y

Chapter 5 IO-Link Events

Events are acyclic transmissions from the IO-Link device to the IO-Link master. Events can be error messages and/or warning or maintenance data.

Code Type Name Description
0 (0x0000) Notification No Malfunction
20480 (0x5000) Error Device hardware fault Device Exchange

13-Aug-24       © Banner Engineering Corp. All rights reserved.

Linkedin icon 1 LinkedIn

Twitter icon 5 X (formerly Twitter)

Facebook icon 23 Facebook