Banner’s LC25 Pro Controller is designed to work with the WLF12 Pro Flexible LED Strip Light product family. It has a low profile, rugged, water-resistant design, making the LC25 ideal for indoor and outdoor applications.

BANNER LC25 Pro Controller with IO-Link - a1
  • In-line controller with M12 connectors
  • Industrial controller between the WLF12 Pro and  an IO-Link master
  • IP65, IP67, and IP68 housing simplifies installation in any location by eliminating the need for a control cabinet
  • Rugged waterproof and dustproof overmolded design
  • Voltage rating of 18 to 30 V DC 
BANNER LC25 Pro Controller with IO-Link - a2

IMPORTANT: Read the following instructions before operating the light. Please download the complete LC25 Pro Controller technical documentation, available in multiple languages, from www.bannerengineering.com for details on the proper use, applications, Warnings, and installation instructions of this device.

LC25 Pro Controller Models

Model

For Use With

LC25C-WLF12-KQ WLF12 Pro Flexible LED Strip Light
Chapter 2  Configuration Instructions
LC25 Pro Controller with WLF12 Wiring

Pro Controller with IO-Link Wiring

4-pin Male M12 Pinout

Pinout Key and Wiring

BANNER LC25 Pro Controller with IO-Link - d11
  1. Brown – 18 V DC to 30 V DC
  2. White – Not used
  3. Blue – DC Common
  4. Black – IO-Link Communication
LC25 Pro with IO-Link Process Data Out (Master to Device)

IO-Link® is a point-to-point communication link between a master device and a sensor and/or light. It can be used to automatically parameterize sensors or lights and to transmit process data. For the latest IO-LINK protocol and specifications, please visit www.io-link.com.

For the latest IODD files, please refer to the Banner Engineering Corp website at: www.bannerengineering.com.

Segment Mode

Configure the light to have up to 10 segments that scale in size automatically with the length of the light or select Manual Segment Configuration which allows each segment to have a custom LED width and LED offset from the beginning of each segment to the beginning of the light.
Use process data to set each segment to off, solid on, flash, or animation mode. Use parameter data to change segment number and configuration, color, intensity, flash speed, direction, background, threshold markers, and select animation type.

Animation 

Description

Off Segment is off
Steady Color 1 is on at the defined intensity
Flash Color 1 flashes at the defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random) 
Two Color Flash Color 1 and Color 2 flash alternately at the defined speed, color intensities, and pattern (normal, strobe, three pulse, SOS, or random)  
Two Color Shift Color 1 and Color 2 flash alternately on adjacent LEDs at the defined speed and color intensities
Ends Steady Color 1 is on in the center of the segment as defined by Percent Width of Color 1 at defined color intensity while Color 2 is solid on for half of the remaining percentage on each end of the segment at defined color intensity
Ends Flash Color 1 is on in the center of the segment as defined by Percent Width of Color 1 at defined color intensity while Color 2 flashes on for half of the remaining percentage on each end of the segment at the defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random)
Scroll Color 1 fills the segment as defined by Percent Width of Color 1 and moves in one direction up or down against the background of Color 2 at the defined speed, color intensities, style, and direction
Center Scroll Color 1 fills the segment as defined by Percent Width of Color 1 and moves in or out from the center of the segment against the background of Color 2 at the defined speed, color intensities, style, and direction
Bounce Color 1 fills the segment as defined by Percent Width of Color 1 and moves up and down against the background of Color 2 at the defined speed, color intensities, and style
Center Bounce Color 1 fills the segment as defined by Percent Width of Color 1 and moves in and out from the center of the segment against the background of Color 2 at the defined speed, color intensities, and style
Intensity Sweep Color 1 repeatedly increases and decreases intensity between 0% to 100% at the defined speed and color intensity
Two Color Sweep Color 1 and Color 2 define the end values of a line across the color gamut. The segment continuously displays a color by moving along the line at the defined speed and color intensities
Spectrum The segment scrolls through 13 predefined colors with a different color on each LED at the defined speed, Color 1 intensity, and direction
Single End Steady Color 1 is solid ON at the defined intensity on one end of the device
Single End Flash Color 1 flashes at the defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random) on one end of the device

Run Mode

Use process data to control the entire light and select color, intensity, flash, direction, and animations. Use parameter data to create custom colors, intensity, and flash speeds.

Animation 

Description

Off Light is off
Steady Color 1 is on at the defined intensity
Flash Color 1 flashes at the defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random) 
Two Color Flash Color 1 and Color 2 flash alternately at the defined speed, color intensities, and pattern (normal, strobe, three pulse, SOS, or random)  
Two Color Shift Color 1 and Color 2 flash alternately on adjacent LEDs at the defined speed and color intensities
Ends Steady Color 1 is on in the center of the light as defined by Percent Width of Color 1 at defined color intensity while Color 2 is solid on for half of the remaining percentage on each end of the light at defined color intensity
Ends Flash Color 1 is on in the center of the light as defined by Percent Width of Color 1 at defined color intensity while Color 2 flashes on for half of the remaining percentage on each end of the light at the defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random)
Scroll Color 1 fills the light as defined by Percent Width of Color 1 and moves in one direction up or down against the background of Color 2 at the defined speed, color intensities, style, and direction
Center Scroll Color 1 fills the light as defined by Percent Width of Color 1 and moves in or out from the center of the light against the background of Color 2 at the defined speed, color intensities, style, and direction
Bounce Color 1 fills the light as defined by Percent Width of Color 1 and moves up and down against the background of Color 2 at the defined speed, color intensities, and style
Center Bounce Color 1 fills the light as defined by Percent Width of Color 1 and moves in and out from the center of the light against the background of Color 2 at the defined speed, color intensities, and style
Intensity Sweep Color 1 repeatedly increases and decreases intensity between 0% to 100% at the defined speed and color intensity
Two Color Sweep Color 1 and Color 2 define the end values of a line across the color gamut. The light continuously displays a color by moving along the line at the defined speed and color intensities
Spectrum The light scrolls through 13 predefined colors with a different color on each LED at the defined speed, Color 1 intensity, and direction
Single End Steady Color 1 is solid on at the defined intensity on one end of the device
Single End Flash Color 1 flashes at the defined speed, color intensity, and pattern (normal, strobe, three pulse, SOS, or random) on one end of the device

Level Mode

Use process data to set the level value. Use parameter data to set range, thresholds, colors, intensities, flash speeds, background, threshold markers, and animation types.

General Settings

Description

Level Mode Value Value of the level of the light (between 0 to 65,535)
Full Scale Value Set the upper limit of the Level Mode Value (between 0 to 65,535)
Background Color and Intensity A defined color and intensity is displayed on LEDs that are not active
Dominance Dominant: The entire light displays the active threshold color
Non-Dominant: LEDs display their defined threshold colors
Sub-Segment Style If Level Mode Value is a partial percentage of an LED, select if the segment will be on steady or analog dimmed to the partial percentage
Filtering Smooths the input signal by varying the sample size
None: There is no filtering
Low: The sample size is short and changes to the input signal are more noticeable
High: The sample size is long and changes to the input signal are less noticeable
Hysteresis Determines the signal value change needed to transition between thresholds and to prevent chatter
None: The value follows the input signal
High: A large value change is needed to transition between thresholds
Level Mode Threshold Markers Threshold markers display LED(s) at the defined thresholds and can be configured as either dominant or non-dominant.
Threshold marker location and width are defined by the offset and width parameters, respectively, in segment mode.

Base and Threshold 1-4 Settings

Description

Threshold Type: Base A defined animation state is displayed on LEDs that are not defined within a threshold
Threshold Type: 1-4 Level Mode Values that conform to Threshold Comparison Type ≤ or ≥ and the Threshold Value Percent are displayed on  LEDs as defined by the threshold color, intensity, flash speeds, and run mode animation types

Dim and Blend Mode

Dim and blend mode uses the light to finely adjust the intensity of one color, or blend between two or three colors.
Use process data to set the dim and blend mode value. Use parameter data to set number of colors, range, colors, and intensities.

General Settings

Description

Dim and Blend Mode Value Value of the intensity of the light in 1 Color mode or value of the blend between colors in 2 and 3 Color mode (between 0 to 65,535)
Full Scale Value Set the upper limit of the Dim and Blend Mode Value (between 0 to 65,535)
Number of Colors 1: Color 1 is on at the intensity defined by the percentage of Dim and Blend Mode Value to the Full Scale Value when Color 1 Intensity is set to high 

2: Color 1 and Color 2 define the end values of a line across the color gamut. The light displays a blended color and moves along the line as defined by the Dim and Blend Mode Value and color intensities. 

3: Color 1 and Color 2 define the beginning and end value of one line across the color gamut. Color 2 and Color 3 define the beginning and end value of a second line across the color gamut. The light displays a blended color and moves along the two lines as defined by the Dim and Blend Mode Value and color intensities. 

Filtering Smooths the input signal by varying the sample size
None: There is no filteringLow: The sample size is short and changes to the input signal are more noticeableHigh: The sample size is long and changes to the input signal are less noticeable

Gauge Mode

Gauge mode uses the light to display a colored band of LEDs in a position proportional to the gauge mode value.
Use process data to set the gauge mode value. Use parameter data to set range, thresholds, colors, intensities, flash speeds, background, threshold markers, and animation types.

General Settings

Description

Gauge Mode Value Value of the band position within the light (between 0 to 65,535)
Full Scale Value Set the upper limit of the Gauge Mode Value (between 0 to 65,535)
Filtering Smooths the input signal by varying the sample size None: There is no filtering Low: The sample size is short and changes to the input signal are more noticeable High: The sample size is long and changes to the input signal are less noticeable
Hysteresis Determines the signal value change needed to transition between thresholds and to prevent chatter None: The value follows the input signal High: A large value change is needed to transition between thresholds
Gauge Mode Threshold Markers Threshold markers display LED(s) at the defined thresholds and can be configured as either dominant or non-dominant.
Threshold marker location and width are defined by the offset and width parameter, respectively, in segment mode.

Center, Threshold 1, and Threshold 2 Settings

Description

Threshold Type: Center Gauge Mode Values not in Threshold 1 or Threshold 2 are positioned on a band of LEDs as defined by the center threshold color, intensity, flash speeds, backgrounds, band size percent width, and run mode animation types
Threshold Type: 1 & 2 Gauge Mode Values that conform to Threshold Comparison Type ≤ or ≥ and the Threshold Value Percent are positioned on  a band of LEDs as defined by the threshold color, intensity, flash speeds, backgrounds, band size percent width, and run mode animation types

LED Mode (Segment of Three LEDs)

Use process data to turn on and select a color for each segment of three LEDs. Use parameter data to set global intensity.

General Settings

Description

Segment 1-64 Color Set chosen LED to off or to a defined color
Segment Mode Intensity Defines intensity of all LEDs turned on

Demo Mode

Demonstrate sequence cycles through 12 different configurations to highlight example applications.

IMPORTANT: Set the number of LED Sections manually in the parameter data or run the LED Section Remote TEACH function to automatically program the number of LED sections.

Chapter 3  LC25 Pro Controller Specifications

Supply Voltage

18 V DC to 30 V DC at 30 mA maximum

Use only with a suitable Class 2 power supply (UL) or a SELV power supply (CE)

See the WLF12 Pro Flexible LED Strip Light Instruction Manual for the WLF12 supply voltage and current.

Different IO-Link masters have different maximum current limits. Use the CSB-M1251FM1251M splitter cable and an external power supply if needed. See Accessories.

NOTICE: The WLF12 is designed to be used with an LC25C and must be no more than 3.05 m (10 ft) apart. Contact the factory for instructions on how to use a WLF12 without an LC25C.

Caution 4 WARNING: The WLF12 will be permanently damaged if a supply voltage of greater than 12 V DC is applied directly to the light.

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Connections

Integral 4-pin M12 male and female quick-disconnect connectors

Mounting

A strip of double-sided very high bonding strength tape is supplied

Multiple bracket options available

Secure cables within 150 mm (5.9 in) of the light

Environmental Rating

IP65, IP67, IP68

Suitable for wet locations per UL 2108

Do not spray cable with a high-pressure sprayer or cable damage will result.

Input Response Time

45 ms maximum

Construction

Connector Body: PVC translucent black

Coupling Material: Nickel-plated brass

Vibration and Mechanical Shock

Vibration: 10 Hz to 55 Hz, 1.0 mm peak-to-peak amplitude per IEC 60068-2-6

Shock: 15G 11 ms duration, half sine wave per IEC 60068-2-27

Operating Temperature

-­40 °C to +50 °C (­-40 °F to +122 °F)

Storage Temperature: ­-40 °C to +70 °C (­-40 °F to +158 °F)

Certifications

CE Icon 8Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM

UKCA Icon

Turck Banner LTD Blenheim House
Blenheim Court
Wickford, Essex SS11 8YT
GREAT BRITAIN

UL Listed Icon

IO-Link logo

Required Overcurrent Protection

Caution 4WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations.

Overcurrent protection is required to be provided by end product application per the supplied table.

Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply.

Supply wiring leads < 24 AWG shall not be spliced.

For additional product support, go to www.bannerengineering.com.

Supply Wiring (AWG)

Required Overcurrent Protection (A) Supply Wiring (AWG) Required Overcurrent Protection (A) 

20

5.0

26

1.0

22

3.0

28

0.8

24

1.0

30

0.5
FCC Part 15 Class A

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.

Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Industry Canada ICES-003(A)

This device complies with CAN ICES-3 (A)/NMB-3(A). Operation is subject to the following two conditions: 1) This device may not cause harmful interference; and 2) This device must accept any interference received, including interference that may cause undesired operation.

LC25 Pro Controller Dimensions

LC25 Pro dimensions

BANNER LC25 Pro Controller with IO-Link - b1

BANNER LC25 Pro Controller with IO-Link - b2 BANNER LC25 Pro Controller with IO-Link - b3 BANNER LC25 Pro Controller with IO-Link - b4

BANNER LC25 Pro Controller with IO-Link - b5

Chapter 4  LC25 Pro Controller Accessories
LMBLC25T
  • Stainless steel clip bracket
  • Includes 1 clip bracket and 2 plastic spacers
  • Clearance hole for M5 hardware
BANNER LC25 Pro Controller with IO-Link - c1
LMBLC25TMAG
  • Magnetic mounting bracket for attachment to steel and iron surfaces
BANNER LC25 Pro Controller with IO-Link - c2

4-Pin Threaded M12 Cordsets—Single Ended

Model Length Style Dimensions

Pinout (Female) 

MQDC-406 2 m (6.56 ft) Straight BANNER LC25 Pro Controller with IO-Link - d1 BANNER LC25 Pro Controller with IO-Link - d2 BANNER LC25 Pro Controller with IO-Link - d3 1 = Brown
2 = White
3 = Blue
4 = Black
5 = Unused
MQDC-415 5 m (16.4 ft)
MQDC-430 9 m (29.5 ft)
MQDC-450 15 m (49.2 ft)
MQDC-406RA  2 m (6.56 ft) Right-Angle BANNER LC25 Pro Controller with IO-Link - d4 BANNER LC25 Pro Controller with IO-Link - d5 BANNER LC25 Pro Controller with IO-Link - d6
MQDC-415RA 5 m (16.4 ft)
MQDC-430RA 9 m (29.5 ft)
MQDC-450RA 15 m (49.2 ft)

4-Pin Threaded M12 Cordsets—Double Ended

Model Length Style Dimensions

Pinout

MQDEC-401SS 0.31 m (1 ft) Male Straight / Female Straight  BANNER LC25 Pro Controller with IO-Link - d7 Female

BANNER LC25 Pro Controller with IO-Link - d10

Male

BANNER LC25 Pro Controller with IO-Link - d11

1 = Brown
2 = White
3 = Blue
4 = Black

MQDEC-403SS 0.91 m (2.99 ft)
MQDEC-406SS 1.83 m (6 ft)
MQDEC-412SS 3.66 m (12 ft)
MQDEC-420SS 6.10 m (20 ft)
MQDEC-430SS 9.14 m (30.2 ft)
MQDEC-450SS 15.2 m (49.9 ft)
MQDEC-403RS 0.91 m (2.99 ft) Male Right-Angle /  Female Straight BANNER LC25 Pro Controller with IO-Link - d8
MQDEC-406RS 1.83 m (6 ft)
MQDEC-412RS 3.66 m (12 ft)
MQDEC-420RS 6.10 m (20 ft)
MQDEC-430RS 9.14 m (30.2 ft)
MQDEC-450RS 15.2 m (49.9 ft)
MQDEC-403RR 0.9 m (2.9 ft)  Male Right-Angle / Female Right-Angle BANNER LC25 Pro Controller with IO-Link - d9
MQDEC-406RR 1.8 m (5.9 ft)
MQDEC-412RR 3.6 m (11.8 ft)
MQDEC-420RR 6.1 m (20 ft)

4-Pin Threaded M12 Splitter Cordsets—Flat Junction

Model Branches (Female) Trunk (Male)

Pinout

CSB-M1240M1240 No branch No trunk Female

BANNER LC25 Pro Controller with IO-Link - d10

Male

BANNER LC25 Pro Controller with IO-Link - d11

1 = Brown
2 = White
3 = Blue
4 = Black

CSB-M1240M1241 2 × 0.3 m (1 ft) No trunk
CSB-M1241M1241 0.30 m (1 ft)
CSB-M1248M1241 2.44 m (8 ft)
CSB-M12415M1241 4.57 m (15 ft)
CSB-M12425M1241 7.60 m (25 ft)
CSB-UNT425M1241 7.60 m (25.0 ft) Unterminated
BANNER LC25 Pro Controller with IO-Link - d12
4-Pin Threaded M12 Male to 5-Pin Threaded M12 Female Splitter Cordset

Model

Branches (Female)

Wiring

S15YB-M124-M124-0.2M L1, L2
2 × 0.2 m (7.9 in)
BANNER LC25 Pro Controller with IO-Link - e1

a) TRUNK (MALE)
b) BRANCH 2 (FEMALE)
c) BRANCH 1 (FEMALE)

BANNER LC25 Pro Controller with IO-Link - e2
R50-4M125-M125Q-P Molded Junction Block
  • Four integral 5-pin M12 female quick-disconnect connectors
  • One integral 5-pin M12 male quick-disconnect connector
  • Parallel wiring
BANNER LC25 Pro Controller with IO-Link - e3
R95-8M125-M125Q-P Molded Junction Block
  • Eight integral 5-pin M12 female quick-disconnect connectors
  • One integral 5-pin M12 male quick-disconnect connector
  • Parallel wiring
BANNER LC25 Pro Controller with IO-Link - e4

5-Pin Threaded M12 Splitter Cordset with Flat Junction—Double Ended

Model Trunk (Male) Branches (Female) Pinout (Male)

Pinout (Female)

CSB4-M1251M1250 0.3 m (0.98 ft) Four (no cable) BANNER LC25 Pro Controller with IO-Link - f1 BANNER LC25 Pro Controller with IO-Link - f2
BANNER LC25 Pro Controller with IO-Link - f3

a) Male Trunk Length

1 = Brown
2 = White
3 = Blue
4 = Black
5 = Gray
CSB-M1251FM1251M
  • 5-pin parallel Y splitter (Male-Male-Female)
  • For full Pro Editor preview capability
  • Requires external power supply, sold separately
BANNER LC25 Pro Controller with IO-Link - g1
PSD-24-4
  • 90 to 264 V AC 50/60 Hz input
  • Includes a 1.8 m (6 ft) US style 5-15P input plug
  • 24 V DC UL Listed Class 2 M12 connector output
  • 4 A total current
BANNER LC25 Pro Controller with IO-Link - g2
PSW-24-2
  • 24 V DC, 2 A Class 2 UL Listed power supply
  • 100 V AC to 240 V AC 50/60 Hz input
  • 3.5 m (11.5 ft) PVC cable with M12 quick disconnect
  • Includes Type A (US, Canada, Japan, Puerto Rico, Taiwan), Type C (Germany, France, South Korea, Netherlands, Poland, Spain, Turkey), Type G (United Kingdom, Ireland, Singapore, Vietnam), and Type I (China, Australia, New Zealand) AC detachable input plugs
BANNER LC25 Pro Controller with IO-Link - g3
PSW-24-1
  • 24 V DC, 1 A Class 2 UL Listed power supply
  • 100 V AC to 240 V AC 50/60 Hz input
  • 2 m (6.5 ft) PVC cable with M12 quick disconnect
  • Includes Type A (US, Canada, Japan, Puerto Rico, Taiwan), Type C (Germany, France, South Korea, Netherlands, Poland, Spain, Turkey), Type G (United Kingdom, Ireland, Singapore, Vietnam), and Type I (China, Australia, New Zealand) AC detachable input plugs
BANNER LC25 Pro Controller with IO-Link - g4
DXMR90-4K Series Controller IO-Link Master
  • One female M12 D-Code Ethernet connector
  • Four female M12 connections for IO-Link master connections
  • One male M12 (Port 0) connection for incoming power and Modbus RS-485, one female M12 connection for daisy chaining Port 0 signals
BANNER LC25 Pro Controller with IO-Link - g5
DXMR110-8K Series Controller IO-Link Master
  • Two female M12 D-Code Ethernet connectors for daisy chaining and communication to a higher-level control system
  • Eight female M12 connections for IO-Link master connections
  • One male M12 connection for incoming power, one female M12 connection for daisy chaining power
BANNER LC25 Pro Controller with IO-Link - g6
Chapter 5  Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com.

For patent information, see www.bannerengineering.com/patents.

Document Information

Document title: LC25 Pro Controller with IO-Link Instruction Manual
Part number: 234629
Revision: A
Original Instructions
© Banner Engineering Corp. All rights reserved.

BANNER LC25 Pro Controller with IO-Link - Bar Code

October 18, 2023        © Banner Engineering Corp. All rights reserved.

Linkedin icon 1 LinkedIn

Twitter icon 5Twitter

Facebook icon 23 Facebook

BANNER LC25 Pro Controller with IO-Link

© 2023. All rights reserved.
www.bannerengineering.com

Documents / Resources

BANNER LC25 Pro Controller with IO-Link [pdf] Instruction Manual
LC25 Pro Controller with IO-Link, LC25, Pro Controller with IO-Link, IO-Link

References

Leave a comment

Your email address will not be published. Required fields are marked *