B PLUS Remote System
System configuration
Function of each component
Driving unit: Small motors, solenoid valves can be connected.
Signal unit: Connects signal units such as detector switches or controllers.
Remote: A unit which is installed on the moving side and has the following functions: to supply power for connected actuators, to transmit input signal from “detectors” to“base” and to output the transmitted signals from“base” to “detectors”
Wiring diagram
Dimension
Specification of the System
Type NPN PNP | RC04T-422N-PU-_ _ RC04T-422P-PU-_ _ | |
Applicable sensor | DC 3-wire sensor | |
Drive voltage | 24V ± 1.5V DC | |
Drive current | ≦ 1A (include output load current) | |
INPUT | Signals | 4 signals |
Current load | ≦ 7mA/1output | |
OUTPUT | Signals | 4 signals + 1 INZONE |
Current load | ≦ 50mA/1output | |
Frequency | 300Hz | |
Operating distance | 0…3mm | |
Center offset | Transmission distance is within 2 mm ± 4 mm | |
Transmission distance 2 mm … 3 mm ± 1.5mm | ||
Operating temperature | 0…+50℃ | |
Protection class | IP67 | |
Protection circuit | output short circuit protection, Output surge suppression | |
Cable | PUR φ 7.7 ( 2×0.5mm2 + 9×0.18mm2) | |
Material | PBT | |
Weight | Body 110g +Cable 75g/m |
Type NPN PNP | RC04E-422N-PU-_ _ RC04E-422P-PU-_ _ | |
Supply voltage | 24 V DC ± 5 % (include ripple) | |
Current active consumption static | Max 1.4 A (with 1A drive) Max 0.2 A (when not facing) | |
INPUT | Signals | 4 signals |
Current load | ≦ 7mA/1output | |
OUTPUT | Signals | 4 signals + 1 INZONE |
Current load | ≦ 50mA/1output | |
Frequency | 300Hz | |
Start-up time *1 | ≦ 0.5s | |
LED indication | Status (Green), Signal (Orange) | |
Operating temperature | 0…+50℃ | |
Protection class | IP67 | |
Protection circuit | output short circuit protection , Output surge suppression, Converse protection , Overtemperature protection, overheationg protection when facing metal *2 Over current protection | |
Cable | PUR φ 7.7( 2×0.5mm2 + 9×0.18mm2) | |
Material | PBT | |
Weight | Body 110g+ Cable 75g |
Applicable sensor
Supply voltage | 24V DC |
Residual voltage | ≦ 6.5V |
Load current | – |
- The time from when the base and remote units are energized in the transmittable area wireless signal transmission is possible.
- Metal protection is a function of metal heat prevention when metal is opposed. Since it is not guaranteed to operate with all metals, please do not deliberately confront the metal against the communication surface.
LED indication
Signal LED (Orange) Base part
The in zone LED lights up when the transmission part and the output part are in a confronting state and communication is possible
Typical Transmitting Diagram (Supply voltage at 24V /non-flush mount)
Documents / Resources