Autonics logoHigh Performance Display Units : RS485 Input
Ordering Information
DS / DA Series
INSTRUCTION MANUAL
TCD210084AD

DS-DA Series High Performance Display Units

Thank you for choosing our Autonics product.
Read and understand the instruction manual and manual thoroughly before using the product.
For your safety, read and follow the below safety considerations before using.
For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.
Keep this instruction manual in a place where you can find easily.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.
Follow Autonics website for the latest information.

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • AEG DVK6980HB 90cm Chimney Cooker Hood - icon 4symbol indicates caution due to special circumstances in which hazards may occur.
    AEG DVK6980HB 90cm Chimney Cooker Hood - icon 4Warning Failure to follow instructions may result in serious injury or death.
  1. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
    Failure to follow this instruction may result in personal injury, economic loss or fire.
  2. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact or salinity may be present. Failure to follow this instruction may result in explosion or fire.
  3. Install on a device panel to use.
    Failure to follow this instruction may result in fire.
  4. Do not connect, repair, or inspect the unit while connected to a power source.
    Failure to follow this instruction may result in fire.
  5. Check ‘Unit Descriptions’ before wiring.
    Failure to follow this instruction may result in fire.
  6. Do not disassemble or modify the unit.
    Failure to follow this instruction may result in fire.

AEG DVK6980HB 90cm Chimney Cooker Hood - icon 4 Caution Failure to follow instructions may result in injury or product damage.

  1. Use the unit within the rated specifications.
    Failure to follow this instruction may result in fire or product damage.
  2. Use a dry cloth to clean the unit, and do not use water or organic solvent.
    Failure to follow this instruction may result in fire.
  3. Keep the product away from metal chip, dust, and wire residue which flow into the unit.
    Failure to follow this instruction may result in fire or product damage.

Cautions during Use

  • Follow instructions in ‘Cautions during Use’. Otherwise, it may cause unexpected accidents.
  • 12 – 24 VDCSKIL QC5359B 02 20V Dual Port Charger - icon 5 model power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  • Install a power switch or circuit breaker in the easily accessible place for supplying or disconnecting the power.
  • Keep away from high voltage lines or power lines to prevent inductive noise. In case installing power line and input signal line closely, use line filter or varactor at power
    line and shielded wire at input signal line.
    Do not use near the equipment which generates strong magnetic force or high frequency noise.
  • This unit may be used in the following environments.
    – Indoors (in the environment condition rated in ‘Specifications’)
    – Altitude max. 2,000 m
    – Pollution degree 2
    – Installation category I

Ordering Information

This is only for reference.
For selecting the specific model, follow the Au tonics web site.

Autonics DS-DA Series High Performance Display Units - icon

  1. Display method
    S: 7-segment
    A: 16-segment
  2. Size
    16 : W 16 × H 24 mm
    22: W 20 × H 33 mm
    40: W 40 × H 60 mm
    60: W 60 × H 96 mm
  3. Display color
    R: Red
    G: Green
  4. Input method (basic unit)
    T: RS485 communication input
    C: RS485 communication input (synchronous time display)

Product Components

  • Product
  • 16 / 22 mm Cap (left-right 1 set)× 1
  • Instruction manual
  • 22 mm Connector × 1

Sold Separately

  • Expansion unit (DS□-□E / DA□-□E)
    : select the same size/display color of basic unit (available to mix the display method)
  • 16 / 22 mm Middle bracket (BK-D□R)
  • 16 / 22 mm Unit-display unit (DU□-□)

Specifications

Model DS16-□□ D□22-□□ D□40-□□ D□60-□□
Display color Red / green model
Power supply 12 – 24 VDCSKIL QC5359B 02 20V Dual Port Charger - icon 5
Allowable voltage range 90 to 110 % of power supply
Current consumption (red) ≤ 20 mA ≤ 25 mA ≤ 55 mA ≤ 65 mA
Current consumption (green) ≤ 15 mA ≤ 20 mA ≤ 40 mA ≤ 45 mA
Size (W×H) 9 × 16 mm 11.2 × 22.5 mm 22.4 × 40 mm 33.6 × 60 mm
Noise immunity ±500 V the square wave noise (pulse width: 1 μs) by the noise simulator
Ambient temperature -10 to 55 ℃, storage: -25 to 65 ℃ (non freezing or condensation)
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH (non freezing or condensation)
Protection rating IP40 (front part)
Approval
Weight (packaged) 01) ≈ 12 g (≈ 52 g) ≈ 17 g (≈ 58 g) ≈ 28 g (≈ 63 g) ≈ 60 g (≈ 110 g)
  1. The package weight of 16 mm / 22 mm expansion unit varies, it based on 3 packages.
    16 mm: ≈ 77 g / 22 mm: ≈ 92 g
Model D□□-□T DS□-□C
Input method RS485 communication RS485 communication (time)
Directly connected Autonics Series CT6, CT4, MP5, MT4, TK / TX, TM2, TM4, THD
Display character (range) 64 characters and symbols display: 0 to 9, A to Z, 27 symbols, decimal point World local time, 12/24-hour, summer time
Max. number of multi- stage 24-unit 10-unit

Communication Interface

 RS485

Model D□□-□T DS□-□C
Protocol Modbus RTU
Application standard Compliance with EIA RS485
Max. connections (setting address) Master 1-unit (01, fixed) / Slave 31-unit (01 to 32) 31-unit (226, fixed)
Comm. type Two-wire half duplex
Comm. distance Max. 800 m
Comm. speed 4800, 9600, 19200, 38400 bps
Comm. response time (Slave) 5 ms, 20 ms
Start bit 1-bit (fixed)
Data bit 8-bit (fixed)
Parity bit NONE (fixed)
Stop bit 1-bit (fixed)

Dimensions

  • Unit: mm, For the detailed drawings, follow the Autonics website.
  • N: number of units

16 mm size
Autonics DS-DA Series High Performance Display Units - Dimensions22 mm size Autonics DS-DA Series High Performance Display Units - Dimensions140 mm size

Autonics DS-DA Series High Performance Display Units - Dimensions260 mm size Autonics DS-DA Series High Performance Display Units - Dimensions3

Panel cut-out

  • Panel thickness: 1.5 to 4 mm

Autonics DS-DA Series High Performance Display Units - Panel

Model A B
16 mm 16N+11 23
22 mm 20N+11 31
40 mm 40N-2 55
60 mm 60N-3 91

Cap

  • 16 mm size
  • 22 mm size

Autonics DS-DA Series High Performance Display Units - Cap

Connector

  • 22 mm size

Autonics DS-DA Series High Performance Display Units - Connector

Connection of Units

16 / 22 mm size

  • Connect a basic unit, expansion units, a unit-display unit from the left and connect the caps the end of right and left.
  • Use the middle bracket (sold separately) to protect deflection when connecting over 7 units. Use one middle bracket per 7 units. (tightening torque: ≤ 0.5 N m)

Autonics DS-DA Series High Performance Display Units - Dimensions4

40 / 60 mm size

  • Connect expansion connectors of units using a ribbon cable. (Figure 1)
  • If the distance between expansion units is far as (Figure 2), you can connect the cable at the soldering pad. To use a soldering pad, remove the protection cover which only expansion units have.
  • See ‘Removing Protection Cover of Expansion Unit’ to detach the cover.

Autonics DS-DA Series High Performance Display Units - Dimensions5

Removing Protection Cover of Expansion Unit

Press the connection parts (4-point) of the protection cover at the top/bottom of the 40 / 60 mm expansion unit with (-) screwdriver and the protection cover is removed. To operate the function set switches, you should remove the protection cover on the rear part.
AEG DVK6980HB 90cm Chimney Cooker Hood - icon 4 Caution: Before removing the protection cover, power must be turned OFF.

Autonics DS-DA Series High Performance Display Units - screwdriver

Software

  • Download the installation file and the manuals from the Autonics website.

DAQMaster

• DAQ Master is the comprehensive device management program for Autonics’ products, providing parameter setting, monitoring and data management.

Example Programs

Download the various example programs from the Autonics website.
[RS485 Input Model] Unit Descriptions

Autonics DS-DA Series High Performance Display Units - Unit Descriptions

  1. Expansion connector Using for connecting expansion unit. See ‘Connection of Units.’
  2. Function set switches Basic unit only
    • Slave mode (JP1 OFF: OpenAutonics DS-DA Series High Performance Display Units - icon1 )
No. Setting value (OFF □■ ON) Function Default
5 ms 20 ms
S1 OFF ON
Comm. response time 5 ms (OFF)
4800 9600 19200 38400
S2 OFF ON OFF ON
S3 OFF OFF ON ON
Comm.
speed (bps)
38400 (S2 / S3: ON)
1 2 31 32
J1 ON OFF  

 

ON OFF
J2 OFF ON ON OFF
J4 OFF OFF ON OFF
J8 OFF OFF ON OFF
J16 OFF OFF ON OFF
Comm. address 1 Comm. address (J1: ON /
J2 to 16: OFF)

• Master mode (JP1 ON: Short Autonics DS-DA Series High Performance Display Units - icon2)

No. Setting value Function Default
Manual Auto
S1 OFF ON
Connection setting method  Manual (OFF)
4800 9600 19200 38400  Comm. speed (bps)  38400 (S2 / S3: ON)
S2 OFF ON OFF ON
S3 OFF OFF ON ON
 

J1 to J8

• If the connection setting method (S1) is the manual (OFF), see the ‘Directly Connected Autonics Series.’ Directly  connected Autonics Series CT 4 (J1: ON / J2 to 8: OFF)
J16 Not used Use Unit-display unit Not used (OFF)
  • Input terminal Basic unit only

[RS485 Input Model] Directly Connected Autonics Series

  • Connecting to a device which supports Master mode displays current value or current value and setting value without PC / PLC.
  • Only for RS485 communication output model supports it among the directly connected Autonics Series. Connect input terminal 4 (A+) and 5 (B-) of display unit to RS485 communication output terminal of the dedicated device.
CT6 CT4 MP5 MT4 TK/TX TM2 TM4 THD
J1 OFF ON OFF ON OFF ON OFF ON
J2 OFF OFF ON ON OFF OFF ON ON
J4 OFF OFF OFF OFF ON ON ON ON
J8 OFF OFF OFF OFF OFF OFF OFF OFF

Not using the highest digit (using manual setting)

CT6 MP5 MT4 TK/TX
J1 OFF ON OFF ON
J2 OFF OFF ON ON
J4 OFF OFF OFF OFF
J8 ON ON ON ON

[RS485 Input Model] Example of Display

  • In case of manual setting, the highest digit may be not used.
    [Refer to CT6(5digit), MP5(4digit), MT4(3digit), TK/TX(3digit, using unit-display unit)]
  • To display the set value (PRESET or SV), connect the same number of units as the current value.
  • CT Series: Displayed in the PRESET 2 position when using the 1-state PRESET model.

Autonics DS-DA Series High Performance Display Units - Display

[RS485 Input Model] Input Data Chart

  • Based on the Slave mode.
  • If there is no input data after supplying the power, the basic unit displays input method character (T).

Autonics DS-DA Series High Performance Display Units - Data Chart

[RS485 (synchronous time display) Model] Unit Descriptions

Autonics DS-DA Series High Performance Display Units - Unit Descriptions1

  1. Expansion connector Using for connecting expansion unit. See ‘Connection of Units.’
  2. Function set switches Basic unit only
    No. Setting value (OFF □■ ON) Function Default
    24-hour 12-hour 01)
    S1 OFF ON
    Time display 24-hour (OFF)
    4800 9600 19200 38400
    S2 OFF ON OFF ON
    S3 OFF OFF ON ON

    01) When setting the 12-hour display, use 16-segment  expansion unit for displaying ‘M’ of AM/PM.

    Comm. speed (bps) 38400 (S2 / S3: ON)
    J1 to J16 See the ‘World Time Zone.’ Select world time zone UTC-11:00 (J1: ON / J2 to 16: OFF)
  3. Delimiter for hour/min/sec Basic unit only
    JP1 Setting value Expansion unit Display e.g.: PM 6 hour 60 min 15 sec (based on 12-hour display)
    Open Sign [ ] DA Series (16-segment) Autonics DS-DA Series High Performance Display Units - icon3
    Short Decimal point[.] DS Series (7-segment) Autonics DS-DA Series High Performance Display Units - icon4
  4. Input terminal Basic unit only
No. Code Function
1 VCC 12 – 24 VDCSKIL QC5359B 02 20V Dual Port Charger - icon 5
2 GND 0 V
3
4 A (+) RS485 A (+)
5 B (-) RS485 B (-)
  • The basic unit supplies the power for expansion unit and the unit-display unit and DATA input.
  • For the 22 mm size model, connect the connector to the input terminal.

[RS485 (synchronous time display) Model] World Time Zone

  • Display the switch setting OFF=0, ON=1.
J1 J2 J4 J8 J16 Time zone Region
0 0 0 0 0 UTC-12:00 International Date Line West
1 0 0 0 0 UTC-11:00 Coordinated Universal Time -11
0 1 0 0 0 UTC-10:00 Hawaii
1 1 0 0 0 UTC-09:00 Alaska
0 0 1 0 0 UTC-08:00 Pacific Time(US&Canada), Baja California
1 0 1 0 0 UTC-07:00 Mountain Time(US&Canada), Arizona, Chihuahua, La Paz, Mazatlan
0 1 1 0 0 UTC-06:00 Guadalajara, Mexico City, Monterrey, Saskatchewan, Central America, Central Time(US&Canada)
1 1 1 0 0 UTC-05:00 Eastern Time(US&Canada), Indiana(East), Bogota, Lima, Quito, Rio Branco, Chemical
0 0 0 1 0 UTC-04:00 Atlantic Time(Canada), Asuncion, Georgetown, La Paz, Manaus, San Juan, Cuiaba
1 0 0 1 0 UTC-03:30 Newfoundland
0 1 0 1 0 UTC-03:00 Greenland, Montevideo, Buenos Aires, Brasilia, Santiago, Salvador, Cayenne, Fortaleza
1 1 0 1 0 UTC-02:00 Coordinated Universal Time -02
0 0 1 1 0 UTC-01:00 Cabo Verde Is., Azores
1 0 1 1 0 UTC 00:00 Coordinated Universal Time, Dublin, Edinburgh, Lisbon, London, Monrovia, Reykjavik, Casablanca
 0  1  1  1  0  UTC+01:00 Belgrade, Bratislava, Budapest, Ljubljana, Prague, Brussels, Copenhagen, Madrid, Paris, Windhoek, Sarajevo, Skopje, Warsaw, Zagreb, West Central Africa, Amsterdam, Berlin, Bern, Rome, Stockholm, Vienna
 1  1  1  1  0  UTC+02:00 Damascus, E.Europe, Beirut, Athens, Bucharest, Amman, Jerusalem, Istanbul, Cairo, Kaliningrad, Tripoli, Harare, Pretoria, Helsinki, Kyiv, Riga, Sofia, Tallinn, Vilnius
0 0 0 0 1 UTC+03:00 Nairobi, Moscow, St. Petersburg, Volgograd, Minsk, Bagh- dad, Kuwait, Riyadh
1 0 0 0 1 UTC+03:30 Tehran
0 1 0 0 1 UTC+04:00 Baku, Abu Dhabi, Muscat, Yerevan, Izhevsk, Samara, Tbilisi, Port Louis
1 1 0 0 1 UTC+04:30 Kabul
0 0 1 0 1 UTC+05:00 Ashgabat, Tashkent, Ekaterinburg, Islamabad, Karachi
1 0 1 0 1 UTC+05:30 Sri Jayewardenepura, Chennai, Kolkata, Mumbai, New Delhi
0 1 1 0 1 UTC+05:45 Kathmandu
1 1 1 0 1 UTC+06:00 Novosibirsk, Dhaka, Astana
0 0 0 1 1 UTC+06:30 Yangon(Rangoon)
1 0 0 1 1 UTC+07:00 Bangkok, Hanoi, Jakarta, Krasnoyarsk
0 1 0 1 1 UTC+08:00 Beijing, Chongqing, Hong Kong, Urumqi, Ulaanbaatar, Irkutsk, Kuala Lumpur, Singapore, Taipei, Perth
1 1 0 1 1 UTC+09:00 Seoul, Yakutsk, Osaka, Sapporo, Tokyo
0 0 1 1 1 UTC+09:30 Darwin, Adelaide
1 0 1 1 1 UTC+10:00 Guam, Port Moresby, Magadan, Brisbane, Vladivostok, Canberra, Melbourne, Sydney, Hobart
0 1 1 1 1 UTC+11:00 Solomon Is., New Caledonia, Chordate
1 1 1 1 1 UTC+12:00 Coordinated Universal Time +12, Anadyr, Petropavlovsk- SK, Auckland, Wellington, Fiji

Autonics logo18, Ban song 513Beon-gil, Sundae, Busan, Republic of Korea, 48002
www.autonics.com
 +82-2-2048-1577
sales@autonics.com

Documents / Resources

Autonics DS-DA Series High Performance Display Units [pdf] Instruction Manual
DS-DA Series High Performance Display Units, DS-DA Series, High Performance Display Units, Performance Display Units, Display Units, Units

References

Leave a comment

Your email address will not be published. Required fields are marked *