Autonics logo BW Series TCD210006AB Single Beam Area Sensors
User Manual Autonics BW Series TCD210006AB Single Beam Area SensorsSingle-Beam Area Sensors

BW Series
PRODUCT MANUAL
For your safety, read and follow the considerations written in the instruction manual, other manuals and Autonics website.
The specifications, dimensions, etc. are subject to change without notice for product improvement. Some models may be discontinued without notice.

Features

  • 20 mm optical pitch minimizes non-detection area (BW20-□)
  • Long sensing distance up to 7 m
  • 22 configurations (number of optics : 4 to 48/optical pitch : 20, 40 mm /detection area : 120 to 940 mm)
  • Mutual interference prevention function, self-diagnosis function, stable operation test
  • Bright LED indicators on emitter and receiver
  • Ambient illuminance : 100,000lux (upgraded feature)
  • IP65 protection structure (IEC standard)

Safety Considerations

  • Observe all ‘Safety Considerations’ for safe and proper operation to avoid hazards.
  • warning 2 symbol indicates caution due to special circumstances in which hazards may occur.

warning 2 Warning Failure to follow instructions may result in serious injury or death.

01. Fail-safe device must be installed when using the unit with machinery that may cause serious injury or substantial economic loss. (e.g. nuclear power control, medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, safety equipment, crime/disaster prevention devices, etc.)
Failure to follow this instruction may result in personal injury, economic loss or fire.
02. Do not use the unit in the place where flammable/explosive/corrosive gas, high humidity, direct sunlight, radiant heat, vibration, impact, or salinity may be present.
Failure to follow this instruction may result in explosion or fire.
03. Do not connect, repair, or inspect the unit while connected to a power source.
Failure to follow this instruction may result in fire.
04. Check ‘Connections’ before wiring.
Failure to follow this instruction may result in fire.
05. Do not disassemble or modify the unit.
Failure to follow this instruction may result in fire.
06. This product is not safety sensor and does not observe any domestic nor international safety standard.
Do not use this product with the purpose of injury prevention or life protection, as well as in the place where economic loss maybe present.
warning 2 Caution Failure to follow instructions may result in injury or product damage.
01. Use the unit within the rated specifications.
Failure to follow this instruction may result in fire or product damage.
02. Use a dry cloth to clean the unit, and do not use water or organic solvent.
Failure to follow this instruction may result in fire.
03. Do not use a load over the range of rated relay specification.
Failure to follow this instruction may result in fire, relay broken, contact melt, insulation failure or contact failure.
Cautions during Use

  • Follow instructions in ‘Cautions during Use’. Otherwise, It may cause unexpected  accidents.
  • 12 – 24 VDCᜡ power supply should be insulated and limited voltage/current or Class 2, SELV power supply device.
  • Use the product, 1 sec after supplying power. When using separate power supply for the sensor and load, supply power to sensor first.
  • When using switching mode power supply to supply the power, ground F.G. terminal and connect a condenser between 0 V and F.G. terminal to remove noise.
  • When connecting a DC relay or other inductive load, remove surge by using diodes or varistors.
  • Wire as short as possible and keep away from high voltage lines or power lines, to prevent surge and inductive noise.
  • This unit may be used in the following environments.
    – Indoors (in the environment condition rated in ‘Specifications’)
    – Altitude max. 2,000 m
    – Pollution degree 2
    – Installation category II

Cautions during Installation

  • Be sure to install this product by following the usage environment, location, and specified ratings. Consider the listed conditions below.
    – Installation environment and background (reflected light)
    – Sensing distance and sensing target
    – Direction of target’s movement
    – Feature data
  • If the installation environment has reflected light from the wall or floor, a interval distance of at least 0.5 m is required.
  • When installing multiple sensors closely, it may result in malfunction due to mutual interference. Install it by referring to the interference protection and the installation
    method in the manual.
  • Do not use in places where the light-receiving sensor is exposed to direct sunlight or where the ambient illumination is higher than the specification.
  • Do not impact with a hard object or bend the cable excessively. That could decrease the product’s water resistance.
  • Use this product after the test. Check whether the indicator works appropriately for the positions of the detectable object.

Ordering Information

This is only for reference, the actual product does not support all combinations.
For selecting the specified model, follow the Autonics website.Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 1

❶ Optical axis pitch
Number: Optical axis pitch (unit: mm
❷ Number of optical axes
Number: Number of optical axes
❸ Control output
No-mark: NPN open collector output
P: PNP open collector output

Product Components

  • Product × 1
  • Instruction manual × 1
  • Bracket A × 4
  • Bracket B × 4
  • Fixing bolt × 8

Sold Separately
Connection cable: CID4-□T(R) (1 set – emitter and receiver)
Connections

Brown 12 – 24 VDCEGO ST1400E ST 56 Volt Lithium Ion Cordless Line Trimmer - Icon 6
Blue  0 V
White SYNC
Black TEST (M/S) (emitter) / OUT (receiver)

■ NPN open collector output
Autonics BW Series TCD210006AB Single Beam Area Sensors - contoller 1■ PNP open collector outputAutonics BW Series TCD210006AB Single Beam Area Sensors - contoller 2OCP (over current protection), SCP (short circuit protection)

Operation Timing Chart

Autonics BW Series TCD210006AB Single Beam Area Sensors - Timing card

Dimensions

• Unit: mm, For the detailed drawings, follow the Autonics website.
Autonics BW Series TCD210006AB Single Beam Area Sensors - Dimensions■ Optical axis Pitch (A, B) 20 mm

Model Product length (0 Num.of optical axes Sensing height
BW20-08(3) 160 8 140 mm
BW20-12(P) 240 12 220 mm
BW20-16(P) 320 16 300 mm
BW20-20(P) 400 20 380 mm
BW20-24(P) 480 24 460 mm
BW20-28(P) 560 28 540 mm
BW20-32(P) 640 32 620 mm
BW20-36(P) 720 36 700 mm
BW20-40(0 800 40 780 mm
BW20-44(P) 880 44 860 mm
BW20-48(P) 960 48 940 mm

Optical axis Pitch (A, B) 40 mm 

Model Product length (L.) Num. of optical axes Sensing height
BW40-04(P) 160 4 120 mm
BW40-06(P) 240 6 200 mm
8W40-08(P) 320 8 280 mm
8W40-10(P) 400 10 360 mm
BW40-12(P) 480 12 440 mm
8W40-14(P) 560 14 520 mm
BW40-16(P) 640 16 600 mm
BW40-18(P) 720 18 680 mm
BW40-20(P) 800 20 760 mm
BW40-22(P) 880 22 840 mm
BW40-24(P) 960 24 920 mm

Bracket AAutonics BW Series TCD210006AB Single Beam Area Sensors - Bracet 1Bracket BAutonics BW Series TCD210006AB Single Beam Area Sensors - Bracet 2

Operation Indicator

Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 ON
Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 OFF
Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 Flashing at 0.5 sec interval
Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5/Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 Flashing simultaneously at 0.5 sec interval
Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Cross-flashing at 0.5 sec interval
Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Sequence flashing at 0.5 sec interval

01) Repeated twice, flashes twice at 0.5 second intervals

Item Emitter indicator Receiver indicator Control output
(Light ON)
Green Red Green Yellow Red
Power ON Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 .
MASTER operation Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4
SLAVE operation Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3
TEST input Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5
Break of emitter Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2
Break of light emitting element Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 OFF
apow
uogentisui
Normal installation Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 OFF
Hysterisis section Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 OFF
Abnormal installation Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 OFF
Stable light ON Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 ON
Unstable light ON Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 ON
Unstable light OFF Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 OFF
Stable light OFF Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 OFF
Break of receiver Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 OFF
Over current Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 OFF
Synchronous line noise Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 4 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 OFF
Emitter failure (Time out) Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 5 OFF
Optical axis misalignment alarm Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 3 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 2

Specifications

Model BW20-❑(P) BW40-❑(P)
Sensing method Through-beam
Light source Infrared LED (850 nm modulated light)
Sensing distance 0.1 to 7.0 m
Sensing target Opaque material
Min. sensing target a 030 mm a. 050 mm
Number of optical axes 8 to 48 4 to 24
Sensing height 140 to 940 mm 120 to 920 mm
Optical axis pitch 20 mm 40 mm
Response time 10 ms
Operation mode Light ON
Functions Emitter OFF (external diagnosis), self-diagnosis
Interference MI
protection
Interference protection by MASTER / SLAVE function”
Synchronization type Timing method by synchronous line
Indicator Emitter: Operation indicator (green, red), receiver: Operation indicator (red, yellow, green)
Approval el Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 6 Autonics BW Series TCD210006AB Single Beam Area Sensors - icon 6
Weight (packaged) 1.4 kg (A-; 2.1 kg) (based on BVV20-48) 1.4 kg (A-; 2.1 kg) (based on BW40-24)

01) Connect ‘(TEST)M/S’ of SLAVE emitter to ‘SYNC’ of MASTER. Refer to the product manual.

Power supply 12 – 24 VDCEGO ST1400E ST 56 Volt Lithium Ion Cordless Line Trimmer - Icon 6 (ripple P-P: .. 10 %)
Current consumption Emitter / receiver: -. 120 mA
Control output NPN or PNP open collector output
Load voltage ≤ 30 VDCEGO ST1400E ST 56 Volt Lithium Ion Cordless Line Trimmer - Icon 6
Load current ≤ 100 mA
Residual voltage NPN: 1 ≤ VDCEGO ST1400E ST 56 Volt Lithium Ion Cordless Line Trimmer - Icon 6, PNP:≤ 2.5 VDCEGO ST1400E ST 56 Volt Lithium Ion Cordless Line Trimmer - Icon 6
Protection circuit Reverse power protection circuit, output short overcurrent protection circuit
Insulation
resistance
a 20 MO (500 VDC≤megger)
Noise immunity ± 240 V the square wave noise (pulse width 1ps) by the noise simulator
Dielectric strength 1,000 VAC– 50 / 60 Hz for lminute
Vibration 1.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 min) in each X, Y, Z direction for 2 hours
Shock 500 m/s2 (= 50 G) in each X, Y, Z direction for 3 times
Ambient illumination (receiver)  Ambient light..  100,000 1.x
Ambient temperature -10 to 55 °C, storage: -20 to 60 °C (no freezing or condensation)
Ambient humidity 35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)
Protection rating IP65 (IEC standard)
Cable spec. Ø5 mm, 4-wire, 300 mm
Connector spec. M12 plug connector
Material Case: AL, front cover and sensing part acryl

Installation Mode

This function is for stable installation.
For the first installation, enter installation mode.

  1. Inputting 0 V to 4th terminal of emitter which is (black) TEST, supply power to the product to enter to the installation mode.
  2. After entering installation mode, install the unit at the position where green LED of receiver operation indicator turns ON.
  3. After installation, disconnect the 4th terminal of emitter (black) TEST and re-supply power to the unit.

Troubleshooting

Malfunction Cause Troubleshootin
Non-operation Power supply Supply the rated power.
Cable incorrect connection, or disconnection Check the wiring connection.
Out of rated sensing distance Use it within rated sensing distance.
Non operation
in
Pollution by dirt of sensor cover Remove dirt by soft brush or cloth.
Connector connection failure of the Check the assembled part connector
Control output is OFF even though there is not a target object. Out of the rated sensing distance Use it within the rated sensing distance.
There is an obstacle to cut off the emitted light between emitter and receiver. Remove the obstacle.
There is strong electric wave or noise generator such as motor, electric generator, or high voltage line, etc. Put away  generator. away the strong electric wave or
noise
LED displays for failure of emitter Break of emitter Contact Autonics Corp.
LED displays for failure of receiver Break of receiver
LED displays for
break of light emitting element
Break of light emitting element
LED displays for synchronous line Synchronous line incorrect connection or disconnection Check the wiring connection.
Break of synchronous circuit of emitter or receiver Contact Autonics Corp.
LED displays for emitter malfunction Break of emitter Treat after checking the emitter display LED.
LED displays for over current Control output line is shorted out. Check the wiring connection.
Over load Check the rated load capacity.

Functions

Interference protection
In case of using 2 sensors in parallel in order to extend sensing width, it may cause sensing error because as light interference. This function is operating a sensor as MASTER and another sensor as SLAVE to avoid these sensing errors by the light interference. Connect ‘(TEST)M/S’ of SLAVE emitter to ‘SYNC’ of MASTER.
• Time chart for MASTER/SLAVE transmission pulseAutonics BW Series TCD210006AB Single Beam Area Sensors - chart

• MASTER / SLAVE connections (NPN open collector output)Autonics BW Series TCD210006AB Single Beam Area Sensors - Timing card 1

• MASTER / SLAVE connections (PNP open collector output)Autonics BW Series TCD210006AB Single Beam Area Sensors - Timing card 2

Emitter OFF (external diagnosis)
When 0 V is applied to the TEST input of the emitter, the light emission is forcibly stopped and the external system can check whether the sensor is operating normally. When the emission is stopped, the light is blocked. In the case of Light ON mode, the control output turns OFF. If the emitting stops, sensor is in light OFF status and control output of receiver turns OFF.
• Connections for TEST inputAutonics BW Series TCD210006AB Single Beam Area Sensors - Timing card 3• Control output pulse by TEST inputAutonics BW Series TCD210006AB Single Beam Area Sensors - Timing card 4■ Optical axis misalignment alarm (low light intensity alarm)
This function outputs optical axis misalignment alarm, when front screen is contaminated with dust, optical axis is misaligned due to vibration, emitter is damaged due to the longterm usage, or light t is not received due to obstacle such as leaves and trash on the product. The control output is changed according to the degree of optical axis misalignment, and the red and green operation indicators of the receiver flash alternately in 0.5 sec, and the yellow operation indicator turns on.
■ Self-Diagnosis
If there is checked malfunction during normal operation by regular self-diagnosis, control output turns OFF and operation indicator displays the state.
For more information, see the “Operation Indicator”

  • Break of emitter circuit
  • Malfunction of MASTER / SLAVE line (operation in MASTER)
  • Break of receiver
  • Control output over current
  • Noise of synchronous line

Installations

■ For direction of installation
Emitter and receiver should be installed in same up/down direction.
Autonics BW Series TCD210006AB Single Beam Area Sensors - recever 1For reflection from the surface of wall and flat
When installing it as below, the light reflected from the surface of wall and flat is not shaded. Please check whether it operates normally or not with a sensing target before
using. (interval distance: ≥ 0.5 m)
Autonics BW Series TCD210006AB Single Beam Area Sensors - recever 2For protection of interference
It may cause interference when installing more than 2 sets of the sensor. In order to avoid the interference of the sensor, please install as following figures and use the transmitted light frequency changing function.
• Transmission direction should be opposite between 2 sets.Autonics BW Series TCD210006AB Single Beam Area Sensors - recever 3• It should be installed out of the interference distance.
: It may be a little different based on installation environment.
: Avoid using the unit in the place where the sensor is exposed directly to the fluorescent light with high speed start or high frequency.Autonics BW Series TCD210006AB Single Beam Area Sensors - recever 4

L Emitter2 (sensing distance) D (installation allowable distance)
1 ~ 3 m ≥ 0.4 m
≥ 3 m L × tan 8 ° = ≥ L × 0.14

Feature Data

■ Parallel shifting characteristic
Autonics BW Series TCD210006AB Single Beam Area Sensors - Feature dataAngle characteristicAutonics BW Series TCD210006AB Single Beam Area Sensors - Feature data 1

Bracket Mounting

Autonics BW Series TCD210006AB Single Beam Area Sensors - Bracet 3

Sold Separately: Connection Cable
• Connecting cable is as one set; each of emitter’s and receiver’s.Autonics BW Series TCD210006AB Single Beam Area Sensors - Bracet 4

Type Model L Cable color
Emitter CID4-❑T 3 / 5 / 7 / 10 / 15 m Black
Receiver CID4-❑R 3 / 5 / 7 / 10 / 15 m Gray

Autonics logo18, Bansong-ro 513Beon-gil, Haeundae-gu
Busan, Republic of Korea, 48002
www.autonics.com 