v2.3 Versa Drapery Motor
“
Product Information
Specifications:
- Product: AUTOMATE | ARC™ Versa Drapery Motor
- Compatibility: Popular drapery track systems
- Power Options: Battery or continuous AC
Product Usage Instructions:
Manual Activation:
The Soft Touch feature enables manual operation when needed. To
activate manual mode, follow the steps in the user manual.
Soft Start & Adjustable Micro USB Battery Check:
To check battery level and initiate charging, connect the micro
USB cable to the motor. The soft start feature ensures a smooth
operation when starting the motor.
Speed Control:
To adjust the motor speed, refer to the programming instructions
provided in the manual. You can increase or decrease the speed
based on your preferences.
Setup:
The AUTOMATE Versa Drapery Motor is designed for easy
incorporation into popular drapery track systems. Follow the
installation guide for proper setup.
FAQ:
Q: How do I set a favorite positioning?
A: To set a favorite position, refer to section 12.1 in the
programming instructions manual.
Q: How do I adjust the motor speed?
A: You can increase or decrease the motor speed by following the
steps outlined in section 13 of the programming instructions.
Q: How do I check the battery level?
A: To check the battery level, use the battery check function
described in section 15 of the programming instructions.
“`
MOTOR PROGRAMMING INSTRUCTIONS
Versa Drapery Motor
INSTR. AUTOMATE_VERSA DRAPERY MOTOR_v2.3 FEBRUARY 2024
MANUAL ACTIVATION
SOFT START & ADJUSTABLE MICRO USB BATTERY CHECK SIMPLIFIED
STOP
SPEED CONTROL CHARGING
ACTION
SET-UP
AUTOMATETM | ARCTM Versa Drapery motor is compatible with popular drapery track systems for easy incorporation of curtains into the ARC motorized platform. The Soft Touch feature enables manual operation when needed.
The AUTOMATE Versa Drapery motor now offers the option to power the motor with a battery or continuous AC.
FEATURES: · Electronic Torque sensing “Auto-set” Limits · 433 MHz Bi-Directional RF Communication · Leveling Control · Inverted or Standard Mount · Favorite Position · Soft start / stop
· Soft touch control · Speed Control
CONTENTS
1 SAFETY INSTRUCTIONS 2 COMPLIANCE STATEMENTS 3 VERSA DRAPERY MOTOR SPECIFICATIONS 4 RATINGS (VERSA BATTERY MODULE) 5 CHARGING (VERSA BATTERY MODULE) 6 WIRING (VERSA AC MODULES) 6.1 US (120V) 6.2 US + Field Plug (120V) 6.3 AU (240V) 7 ASSEMBLY 7.1 Attaching and removing the motor 7.2 Attaching and removing the battery or AC module 8 P1 BUTTON FUNCTIONS 8.1 Motor State Test 9 INITIAL SET UP 9.1 Pair motor with controller 9.2 Check/ Change motor direction (initial set up) 9.2.1 Check/ Change motor direction (initial set up) 9.3 Auto Set Limits 10 ADJUSTING LIMITS 10.1 Adjust open limit 10.2 Adjust close limit 10.3 Delete limits 11 CONTROLLERS AND CHANNELS 11.1 Using motor P1 button 11.2 Using existing controller to add a new controller or channel 11.3 Using pre-existing controller to add or delete a controller or channel
2 | AutomateTM Programming Instructions | Versa Drapery Motor
4 5 6 7 7 8 8 8 9 10 11 12 13 13 14 14 14 15 15 16 16 16 17 17 17 18 18
ROLLEASE ACMEDA
CONTENTS
12 FAVORITE POSITIONING
19
12.1 Set a favorite position
19
12.2 Send to favorite position
19
12.3 Delete favorite position
19
13 ADJUST MOTOR SPEED
20
13.1 Increase motor speed
20
13.2 Decrease motor speed
20
14 SOFT TOUCH FUNCTION
21
14.1 Operating with Soft Touch Function
21
14.2 Turn soft touch function on/off
21
15 BATTERY CHECK FUNCTION
22
15.1 Send curtain to battery charge level
22
16 RS485 COMMUNICATION
22
16.1 Enable RS485 communication
22
16.2 Disable RS485 communication
23
16.3 RS485 Failure
23
17 SLEEP MODE
24
17.1 Enter Sleep Mode
24
17.2 Exit Sleep Mode
24
18 EXTERNAL LOW VOLTAGE SWITCH MODE
25
18.1 Two Button Spring Return Switch (Default Mode)
25
18.2 Three Button Spring Return Switch
25
18.3 Single Button Spring Return Switch
26
19 TROUBLESHOOTING
27
3 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
1 SAFETY INSTRUCTIONS
WARNING: Important safety instructions to be read before installation.
Incorrect installation can lead to serious injury and will void manufacturer’s liability and warranty.
· Do not expose to moisture or extreme temperatures. · Do not allow children to play with this device. · Use or modification outside the scope of this
years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or
instruction manual will void warranty.
· Installation and programming to be performed by a
instruction concerning use of the appliance in a safe way and understand the hazards involved. Children
suitably qualified installer.
· For use within curtains and drapes. · Use only Rollease Acmeda hardware. · Before installation, remove any unnecessary cords
shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without
supervision.
· Frequently examine the installation for imbalance and
and disable any equipment not needed for powered
signs of wear or damage to cables and springs. Do not
operation.
· Ensure torque and operating time is compatible with
use if repair or adjustment is necessary.
· This appliance is intended to be used to drive drapes
end application.
and curtains, etc.
· · Do not expose the motor to water or install in humid or
Hazardous unprotected moving parts of the drive shall
damp environments.
be installed higher than 2,5 m above the floor or other
· Motor is to be installed in vertical application only.
level that could provide access to it.
· Do not drill into motor body.
· Install the actuating member of a manual release at a
· The routing of cable through walls shall be protected
height less than 1.8m.
by isolating bushes or grommets.
· That the actuating member of a biased-off switch
· Ensure power cable is clear and protected from moving
is to be located within direct sight of the driven part
parts.
· If cable or power connector is damaged do not use. · Ensure all mechanical connections are secure. · Risk of Electric Shock, Dry location use only for indoor
but away from moving parts. It is to be installed at a
minimum height of 1,5 m and not accessible to the
public.
· The mass and the dimension of the driven part shall be
use only.
· This appliance can be used by children aged from 8
compatible with the rated torque and rated operating time.
Important safety instructions to be read prior to operation.
· It is important for the safety of persons to follow the enclosed instructions. Save these instructions for future reference. · Persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge
should not be allowed to use this product.
· Keep remote controls away from children. · Frequently inspect for improper operation. Do not use if repair or adjustment is necessary. · Keep motor away from acid and alkali. · Keep clear when in operation. · Electrical wiring must be carried out by a licensed electrician.
4 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
2 COMPLIANCE STATEMENTS
WARNING: Important safety instructions to be read before installation and use.
Incorrect installation or use can lead to serious injury and will void manufacturer’s liability and warranty. It is important for the safety of persons to follow the enclosed instructions.
Save these instructions for future reference.
· Do not put in fire.
· Do not expose to water, moisture, humid and damp environments or extreme temperatures.
· Installation and programming to be performed by a suitably qualified installer.
· Follow installation instructions.
· Do not crush, puncture, disassemble and damage.
· For use with motorized shading devices.
· Do not expose to temperature above 60°C / 140°F.
· Frequently inspect for improper operation.
· Do not short circuit the battery module.
· Do not use if repair or adjustment is necessary.
· Do not leave the battery module on prolonged charge when not
· Keep clear when in operation.
in use.
· Replace battery with correctly specified type.
· Persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, should ·
Avoid in direct sunlight or rain.
not be allowed to use this product.
· The battery module needs to be charged before use. Use the
· Use or modification outside the scope of this instruction manual will void warranty.
battery module only for the versa drapery motor. Refer to Versa Drapery Motor instruction manual for assembly.
FCC & ISED Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
Caution: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :
1) L’appareil ne doit pas produire de brouillage;
2) L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequencyenergy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
· Reorient or relocate the receiving antenna.
· Increase the separation between the equipment and receiver.
· Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
· Consult the dealer or an experienced radio/TV technician for help.
Do not dispose of in general waste. Please recycle batteries and damaged electrical products appropriately.
5 | AutomateTM Programming Instructions | Versa Drapery Motor
CAN ICES-3 (B)/NMB-3(B)
ROLLEASE ACMEDA
3 VERSA DRAPERY MOTOR SPECIFICATIONS
Code
Description
Region Power Cable Length Voltage Output Voltage Input Capacity Running Time Current Power Stored Energy Charge Voltage Protection Class Torque Speed Frequency Sound Level
Weight
RF Protocol RF Modulation RF Signal Range Limit Switch Type
Temperature Range
Limit Range Insulation Class Life Cycle Testing Charge Time Solar Panel Gen2
VERSA DRAPERY MOTOR SPECIFICATIONS
MT01-2101-xxx002 MT03-0305-xxx004 MT03-0305-069005 MT03-0305-069006
Versa Drapery Motor Battery Module
AC Module 10′ Cord AC Module 20′ Cord + Plug
AU / EU / US
AU / EU / US
US
US
–
3m [ 10′ ]
6.1m [ 20′ ]
–
14.4V DC
18.0V DC
15V DC
–
120V AC 60 Hz
–
2.55 Ah
–
12 min
–
–
1.3 A
–
2.0 A
20.0 W
–
36.0 W
–
36.72 Wh
–
–
5V DC (Micro USB)
–
IP20
1.2 Nm
–
80 | 100 | 120
–
433.925 MHz *
–
44 dB
–
0.83 Kg
0.27 Kg
0.32 Kg
0.49 Kg
1.83 lbs
0.60 lbs
0.71 lbs
1.08 lbs
ARC
–
FSK
–
15m [ 49 ft ]
–
Electronic
–
-10 – 50 °C
0 – 45 °C
-10 – 50 °C
14 – 122 °F
32 – 113 °F
14 – 122 °F
–
Class A
10,000 Cycles| 50 Kg | Upto 11m Track
–
8 hrs @ 2A
–
–
5V USB Compatible
–
MT03-0305-xxx012 AC Module 2.5m Cord
AU 2.5m [ 8.2′] 240V AC 50Hz
0.30 Kg 0.66 lbs
Notes * Maximum transmitted power 10 mW Motor/Battery protection activates when battery voltage reaches 13.5V DC (motor stops when battery is flat) 120 RPM is Default speed in operation ( 80 RPM is defult speed during limit setting ) Charge time is based on typical 5V / 2A charge rate of fully discharged battery, actual time may vary between batteries
Versa Battery Module
Model: MT03-0305-xxx004
Versa AC Module
Model: MT03-0305-069005 MT03-0305-069006 MT03-0305-xxx012
6 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
4 RATINGS (VERSA BATTERY MODULE)
Model: MT03-0305-xxx004 Typical output voltage: 16.8VDC
Charge: 5VDC 2A or 5VDC 1A with USB plug
Rate output voltage: 14.4VDC Nominal capacity: 2.55Ah
5 CHARGING (VERSA BATTERY MODULE)
CHARGERS Strongly recommended chargers: · RA US model: MT03-0301-069008 (marked as MX15W-0502000UU) · RA AU model: MT03-0301-069011 (marked as MX15W-0502000SU) However, the battery module also accepts universal 5VDC 2A/1A USB chargers.
Important: Before first use, charge battery fully until LED indicator turns Green (Solid) Solid Red = Charging Solid Green = Fully Charged Charge battery using 5V Micro USB
Battery Charge LED Indicator
7 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
6 WIRING (VERSA AC MODULES)
6.1 US (120V)
Disconnect the mains power supply. Connect the motor according to the information in the table below.
Ensure cable is kept clear of fabric.
1
Power OFF
2
1
2
MT03-0305-069005
MT03-0305-069006
MOTOR MT03-0305-069005 MT03-0305-069006
POWER 120V AC / 60Hz
NEUTRAL White
LIVE Black
EARTH N/A
POWER CORD LENGTH 10 ft (3m) 20 ft (6.1m)
6.2 US + Field Plug (120V)
Connect the motor according to the information in the table below. Ensure cable is kept clear of fabric.
Right Angle Field Plug
FIELD PLUG MT03-0601-069001
POWER 125V AC / 60Hz
8 | AutomateTM Programming Instructions | Versa Drapery Motor
NEUTRAL White
LIVE Black
EARTH Green
ROLLEASE ACMEDA
6 WIRING (VERSA AC MODULES) 6.3 AU (240V)
Connect the motor according to the information in the table below. Ensure cable is kept clear of fabric.
MOTOR MT03-0305-xxx012
POWER 240V AC 50Hz
NEUTRAL Blue
LIVE Brown
EARTH N/A
POWER CORD LENGTH 8.2 ft (2.5m)
9 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
7 ASSEMBLY
GENERAL SCHEMATIC
2. 1a. 1b.
1a. 3.
4a.
WARNING:
4b.
ENSURE PROPER ORIENTATION OF THE
4c.
MASTER CARRIER WHEN ASSEMBLING THE
SYSTEM. THE MASTER CARRIER SHOULD BE
ATTACHED TO THE BELT EXACTLY AS
DESCRIBED AND DEPICTED IN THIS
ASSEMBLY GUIDE TO ENSURE CORRECT
SETTING AND FUNCTIONALITY OF THE
MOTOR LIMITS.
SYSTEM INDEX: 1a. Motor End Pulley 1b. Overlap Return Pulley 2. Curtain Track
3. Versa Drapery Motor 4a. Battery 4b. AC Power Adapter
10 | AutomateTM Programming Instructions | Versa Drapery Motor
4c. AC Power Adapter (Long Cable)
ROLLEASE ACMEDA
7 ASSEMBLY
7.1 Attaching and removing the motor
ATTACHING THE MOTOR TO DRIVE PULLEY STEP 1 Slide the lock button fully left against the spring pressure force
STEP 4
CHECK the Motor and Pulley are securely attached by trying to pull them apart.
STEP 2 Align and engage the Motor with the Drive Pulley as shown.
REMOVING THE MOTOR FROM THE DRIVE PULLEY
STEP 1 Slide the lock button fully left against the spring pressure force
STEP 3
Push to Lock Button fully to the right to ensure they two are securely attached.
STEP 2 Pull the Motor away from the Drive Pulley
11 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
7 ASSEMBLY
7.2 Attaching and removing the battery or AC module
ATTACHING THE BATTERY OR AC MODULE TO THE MOTOR STEP 1 Slide the lock button fully left against the spring pressure force
STEP 4
CHECK the Motor and Battery (or AC Module) are securely attached by trying to pull them apart.
STEP 2 Align and engage the Battery or AC Module with the Motor as shown.
REMOVING THE BATTERY OR AC MODULE FROM THE MOTOR
STEP 1 Slide the lock button fully left against the spring pressure force
STEP 3
Push to Lock Button fully to the right to ensure they two are securely attached.
STEP 2 Pull the battery or AC module away from the motor
12 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
8 P1 BUTTON FUNCTIONS
8.1 Motor State Test
This table describes the function of a short P1 button press/release(<2 seconds) depending on current motor configuration.
P1 Press
Condition
Function Achieved
Visual Feedback
Short Press then
Release (<2 sec)
If limit is NOT set
If limits are set
If motor is in “Sleep Mode” & limits are set
(Refer to Sec.10)
None Operational control of motor, run to limit. Stop if
running
Wake and control
No Action
Motor runs
Motor wakes and runs in a
direction
Audible Feedback
None None
None
Function Described
No Action
Operational control of motor after pairing and limit setting
is completed first time
Motor is restored from Sleep mode and RF control is active
Hold P1 button on motor head. Activate Pairing Mode
GREEN LED
Approx.
Sleep Mode
P1 Button LED
RJ45 Antenna Hole
Approx.
Approx.
Enter Setting Mode
Approx.
Approx.
Approx. 10
Reset To Factory Settings
Approx.
Approx.
Approx. 10
Approx.
13 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
9 INITIAL SET UP
9.1 Pair motor with controller
Select channel on controller.
Hold P1 button on motor head.
P1
Hold STOP on controller.
IMPORTANT
Consult user manual for your controller for information on selecting channel.
Motor Response
Motor Response Approx.
Motor is now in setup mode and ready for setting limits
Notes:
·
When limits are not set only one remote channel can be paired with the motor
·
When limits are set, up to ten channels can be paired with the motor
9.2 Check/ Change motor direction (initial set up)
To check travel direction of shade, press UP or DOWN on controller..
To reverse shade direction, hold both UP and DOWN. Until the motor responds.
OR
Quick Press = Step Long Press = Continuous Travel
Motor Response Approx.
14 | AutomateTM Programming Instructions | Versa Drapery Motor
IMPORTANT
Reversing motor direction using this method is only possible during initial set-up
ROLLEASE ACMEDA
9.2.1 Check/ Change motor direction (initial set up)
Press P1 on Motor for 10 seconds to enter setting mode
P1
To reverse direction, hold both UP and DOWN. Until the motor
responds.
Motor Response
Motor Response Approx.
Approx.
Approx.
Approx. 10
Note:
Changing motor direction after initial set up (with limits already set) will clear the limits. Open and close the curtain to re-set the limits automatically.
9.3 Auto Set Limits
The AUTOMATE Versa Drapery motor features automatic limit detection. Once the motor is attached to a fabricated, installed track, limits can be set with a few simple actions.
Press the UP or DOWN buttons on controller. Carrier will run to the end of the track.
When carrier has reached the end of the track, it will automatically set limit there.
Repeat for opposite end.
OR
Motor Response
Approx.
IMPORTANT
To verify limits were successfully set, press up or down to run to limit. Motor should now function with slow start/slow stop feature. After the limits are set, the motor will only move in the set limit range. If the motor encounters a new obstacle a maximum of THREE TIMES at the same position, the limit will automatically reset. Note: If the motor encounters an obstacle, collision detection will stop the motor to prevent damage.
Initial set-up is now complete
15 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
10 ADJUSTING LIMITS
10.1 Adjust open limit
Hold UP and STOP on controller.
Move curtain to the desired open position by pressing the UP or DOWN button.
OR
Motor Response Approx. 5 SECS
To save desired open limit, hold UP and STOP.
Motor Response Approx. 5 SECS
10.2 Adjust close limit
Hold DOWN and STOP on controller.
Move curtain to the desired closed position by pressing
the UP or DOWN button.
OR
To save desired close limit, hold DOWN and STOP.
Motor Response Approx. 5 SECS
Motor Response Approx. 5 SECS
Notes:
· Once in limit adjustment mode, button selection on the remote must be made within 2 minutes, if not, motor will exit adjustment mode.
· To exit limit adjustment mode without making changes, press P1 or P2 and limits will remain unchanged.
16 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
10.3 Delete limits
Press P2 on controller
Press DOWN on controller
Press P2 on controller
Motor Response
Motor Response
Motor Response
11 CONTROLLERS AND CHANNELS
11.1 Using motor P1 button
Hold P1 button on motor head.
P1
Hold STOP on controller to add or remove
Motor Response
Motor Response Approx.
17 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
11.2 Using existing controller to add a new controller or channel
A= Existing controller or channel (to keep) B= Controller or channel to add or remove
Press P2 on controller A
Press P2 on controller A
Press STOP on the new controller to add it
Motor Response
Motor Response
Motor Response
IMPORTANT
Consult user manual for your controller or sensor
11.3 Using pre-existing controller to add or delete a controller or channel
A= Existing controller or channel (to keep) B= Controller or channel to add or remove
Press P2 on controller A
Press P2 on controller A
Press P2 on controller B to
remove it
Motor Response
Motor Response
IMPORTANT
Consult user manual for your controller or sensor 18 | AutomateTM Programming Instructions | Versa Drapery Motor
Motor Response ROLLEASE ACMEDA
12 FAVORITE POSITIONING 12.1 Set a favorite position
Move curtain to desired position by pressing the UP or DOWN button on the controller. Move shade to the desired position by pressing the UP or DOWN button on the controller.
OR
Press P2 on controller.
Press STOP on controller.
Press STOP on controller.
Motor Response
Motor Response
Motor Response
12.2 Send to favorite position
Press STOP on controller.
Approx.
12.3 Delete favorite position
Press P2 on controller.
Press STOP on controller.
Press STOP on controller.
Motor Response
Motor Response
19 | AutomateTM Programming Instructions | Versa Drapery Motor
Motor Response ROLLEASE ACMEDA
13 ADJUST MOTOR SPEED
Notes: · There are three speed settings (80,100 & 120 RPM). · With limits set, the default speed is MAXIMUM speed. · If motor responds to the inputs below with two quick beeps, the speed setting is already at the maximum
or minimum speed trying to be set. · When motor limits are not set, default speed is minimum.
13.1 Increase motor speed
Press P2
Press UP
Press UP
Motor Response
Motor Response
Motor Response
13.2 Decrease motor speed
Press P2
Press DOWN
Press DOWN
Motor Response
Motor Response
Motor Response
20 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
14 SOFT TOUCH FUNCTION
The AUTOMATE Versa Drapery Motor exhibits a built-in function which enables the motor to be initiated by hand-draw. When the fabric is displaced more than 10cm by hand-draw, the motor continues to move towards the drawn direction, until the limit is reached.
The Soft Touch Function can be toggled on and off by pressing the P1 button for 10 seconds, followed by the STOP button.
14.1 Operating with Soft Touch Function
OPEN
CLOSED
Hand-draw curtain fabric 10cm to initiate Soft Touch function
14.2 Turn soft touch function on/off
Continuously hold P1 button on motor head for 10 seconds
P1
Press STOP on controller to switch soft touch function on or off.
Motor Response
Approx.
Approx.
Approx. 10
Motor Response
21 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
15 BATTERY CHECK FUNCTION 15.1 Send curtain to battery charge level
Hold UP
Percentage of Battery Charge Remaining
Open Limit Closed Limit Percentage Depleted
Motor Response Approx. 5 SEC
Hold UP for Approx. 5s Curtain will close first if not already closed
Curtain then moves to percentage of battery charge remaining
16 RS485 COMMUNICATION
Notes: · Default RS485 function is disabled. · RS485 function is not available when motor is powered by the Battery. · RS485 function is ONLY available when motor is powered by AC Module. · Motors must be paired one at a time with control PC when multiple motors are to be connected on a
network.
16.1 Enable RS485 communication
Continuously hold P1 button on motor head for 2 seconds
P1
Hold UP on controller for 5 seconds
Motor Response
Motor Response
22 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
16.2 Disable RS485 communication
Continuously hold P1 button on motor head for 2 seconds
P1
Hold UP on controller for 5 seconds
Motor Response
Motor Response
16.3 RS485 Failure
RS485 failure reminder when trying to turn on RS485 function of battery powered motor:
Continuously hold P1 button on motor head for 2 seconds
P1
Hold UP on controller for 5 seconds
Motor Response
Motor Response
23 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
17 SLEEP MODE
If multiple motors are grouped on a single channel, Sleep Mode may be used to put all but 1 motor to sleep, allowing programming of just the one motor that remains “Awake”. See page 6 for detailed P1 functions.
17.1 Enter Sleep Mode
Enter Sleep Mode Sleep mode is utilized to prevent a motor from incorrect configuration during other motor setup.
Hold P1 button on the motor head
Motor Response
Approx.
Notes: In sleep mode, the Soft Touch Function is available and operating the curtain via this method will not cause the motor to exit sleep mode.
17.2 Exit Sleep Mode
Exit Sleep Mode: Method 1 Exit sleep mode once the shade is ready. Press and release P1 button on the motor head
Motor Response
Motor will move in last default direction to limit position
Exit Sleep Mode: Method 2 Remove power and then re-power the motor.
24 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
18 EXTERNAL LOW VOLTAGE SWITCH MODE
18.1 Two Button Spring Return Switch (Default Mode)
Press P1 on motor for 10 seconds to enter setting mode
Press P2 on controller
P1
Press P1 on motor for 2 seconds
P1
Motor Response
Approx.
Approx.
Approx. 10
Motor Response
Motor Response
18.2 Three Button Spring Return Switch
Press P1 on motor for 10 seconds to enter setting mode
REPEAT 2X
Press P2 on controller
P1
Press P1 on motor for 2 seconds
P1
Motor Response
Motor Response
Approx.
Approx.
Approx. 10
25 | AutomateTM Programming Instructions | Versa Drapery Motor
Motor Response ROLLEASE ACMEDA
18.3 Single Button Spring Return Switch
Press P1 on motor for 10 seconds to enter setting mode
REPEAT 3X
Press P2 on controller
P1
Press P1 on motor for 2 seconds
P1
Motor Response
Approx.
Approx.
Approx. 10
Motor Response
Motor Response
26 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
19 TROUBLESHOOTING
Problem
Motor is not responding
Motor Beeps + Flashes x4 Times Cannot program a single Motor (multiple motors respond)
Cause
Remedy
A / C power supply not plugged in.
Check motor to power cable connection and AC plug
Insufficient charging from solar PV panel
Check connection and orientation of PV panel
Transmitter battery is discharged Replace battery
Incorrect Wiring (AC Module power)
Check wiring of Field Plug if not factory fitted
Radio interference/shielding
Ensure transmitter is positioned away from metal objects and the aerial on motor or receiver is kept straight and away from metal
Receiver distance is too far from Move transmitter to a closer
transmitter
position
Charging failure
Connect battery to charger and check if LED indicates charging
Battery voltage is low
Recharge with a compatible charger
Always reserve an individual channel for programming functions
Multiple motors are paired to the same channel.
SYSTEM BEST PRACTICE – Provide an extra 15 channel remote in your multi motor projects, that provides individual control for each motor for programming purposes
Place all other motors into sleep mode. Refer to sleep mode section.
27 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA
ROLLEASE ACMEDA | USA Level 7 / 750 East Main Street Stamford, CT 06902, USA T +1 800 552 5100 | F +1 203 964 0513
ROLLEASE ACMEDA | AUSTRALIA 110 Northcorp Boulevard, Broadmeadows VIC 3047, AUS T +61 3 9355 0100 | F +61 3 9355 0110
28 | AutomateTM Programming Instructions | Versa Drapery Motor
ROLLEASE ACMEDA | EUROPE Via Conca Del Naviglio 18, Milan (Lombardia) Italy T +39 02 8982 7317 | F +39 02 8982 7317
ROLLEASE ACMEDA
Documents / Resources
![]() |
AUTOMATE v2.3 Versa Drapery Motor [pdf] Instruction Manual v2.3 Versa Drapery Motor, v2.3, Versa Drapery Motor, Drapery Motor, Motor |