S8-BT Standalone Access Control
“
Specifications
- User Capacity:
- Common User: 990
- Visitor User: 10
- Operating Voltage: 12-24V DC
- Working Current: Drill 2 holes(A,C) on the wall for the screws
and one hole for the cable - Idle Current: Knock the supplied rubber bungs to the screw
holes(A,C) - Proximity Card Reader Radio Technology
- Read Range: Read Range
- PIN Length: Wiring Connections
Product Usage Instructions
Installation
- Drill 2 holes (A, C) on the wall for the screws and one hole
for the cable. - Knock the supplied rubber bungs to the screw holes (A, C).
- Fix the back cover firmly on the wall with 4 flat head
screws. - Thread the cable through the cable hole (B).
- Attach the unit to the back cover.
Basic Configuration
- Enter Program Mode: Press * followed by
MasterCode (#) (Factory default is 123456). - Exit Program Mode: Press *.
Set Master Code
- Enter Program Mode.
- Update Master Code by entering 0 followed by New Master Code
and repeat it (#). - Exit Program Mode by pressing *.
Connection Diagram
Common Power Supply Attention: Install a 1N4004
or equivalent diode when using a common power supply to prevent
damage to the keypad. (1N4004 is included in the packing)
Access Control Power Supply
Programming: Programming instructions will vary
based on access configuration. Follow the specific instructions for
your setup.
Notes:
- User ID number: Assign a user ID to the access card/PIN for
tracking purposes. - Common User ID: PIN/Card user ID: 0-989,
Visitor User ID: 990-999 - Proximity Card: 125KHz EM card or 13.56MHz
Mifare card - PIN: Can be any 4-6 digits except 8888, which
is reserved. Enter PIN on the Infrared Remote Control.
FAQ
Q: How many users does the device support?
A: The device supports 1,000 users, including 990 common users
and 10 visitor users.
Q: Can I use a common power supply without any additional
precautions?
A: When using a common power supply, it is important to install
a 1N4004 or equivalent diode to prevent potential damage to the
keypad. The diode is included in the packaging for your
convenience.
“`
Proximity Access Control
User Manual
INTRODUCTION —————————————————–
The device is a single door standalone access control with Wiegand input & output. It uses Atmel MCU assuring stable performance. The operation is very user-friendly, and low-power circuit makes it long service life.
The device supports 1,000 users (990 common users + 10 visitor users). It supports multi access modes in card access, PIN access, card + PIN access, or multi cards/PINs access.
Optional Version: The device with Bluetooth-enabled. People can install the Bluetooth APP to easily access the door with their smartphone. (APP operation can refer from APP manual)
Features
> Waterproof, conform to IP66 > Vandal resistant metal enclosure > One relay, 1,000 users (990 common + 10 visitor) > Can add any 4~6 digits PIN on Infrared Remote Control > Card Type: 125Khz EM Card/13.56Mhz Mifare Card (optional) > Wiegand 26 bits output, Wiegand 26/34bits input automatic identification > Card block enrollment > Tri-color LED status display > Pulse mode, Toggle mode > Low temperature resistance (-40°C)
Specifications User Capacity
Common User Visitor User
Operating Voltage
Working Current Idle Current
Proximity Card Reader
Radio Technology Read Range
PIN Length Wiring Connections
1000
990 10
12-24V DC
<150mA <60mA EM or Mifare 125KHz /13.56MHz 2 6 cm
4~6 digits
Relay Output, Exit Button, Wiegand Input, Wiegand Output
1-
–
Relay
Adjustable Relay Output Time Lock Output Load
Wiegand Interface
Environment
Operating Temperature Operating Humidity
Physical
Surface Finish Dimensions
Unit Weight Shipping Weight
Carton Inventory
One (NO, NC, Common)
099 Seconds (5 seconds default) 2 Amp Maximum
Wiegand 26 bits output Wiegand 26/34bits input automatic identification Outdoor (Meets IP66)
-40°C 60°C (-40°F 140°F) 0%RH 98%RH
Zinc-Alloy
Powder Coat D73 x H20mm (Round) L105xW69xH20(Ellipse)
180g (Round) 220g (Ellipse) 260g (Round) 280g (Ellipse)
INSTALLATION ——————————————————
> Remove the back cover from the unit > Drill 2 holes(A,C) on the wall for the screws and one hole for the cable > Knock the supplied rubber bungs to the screw holes(A,C) > Fix the back cover firmly on the wall with 4 flat head screws > Thread the cable through the cable hole(B) > Attach the unit to the back cover
2-
–
Wiring
Colour Red Black Blue Brown Grey Yellow Green White
Function Power + GND NO COM NC OPEN DO D1
Notes 12-24V DC Votes DC Regulated Power Input Ground Normally Open Relay Output Common Connection for Relay Output Normally Closed Relay Output Request to Exit input(REX) Wiegand Input/Output Data 0 Wiegand Input/Output Data 1
Sound and Light Indication Operation Status
Stand by Enter into programming mode In the programming mode Operation error Exit from the Programming mode
LED
Red light bright Red light shines Orange light bright
Red light bright
Buzzer
One beep One beep Three beeps One beep
Open lock Alarm
Green light bright
One beep
Red light Shines quickly Beeps
Basic Configure———————————————————————–
Enter and Exit Program Mode Programming Step
Keystroke Combination
Enter Program Mode
* (MasterCode)#
(Factory default is 123456)
Exit Program Mode
*
3-
–
Set Master Code Programming Step
1. Enter Program Mode 2. Update Master Code
3. Exit Program Mode
Keystroke Combination
·k (Master Code) #
0 (New Master Code) # (Repeat New Master Code) #
(Master code is any 6 digits)
*
Connection Diagram———————————————-
Common Power Supply
Attention:
Install a 1N4004 or equivalent diode is needed when use a common power supply, or the keypad might be damaged. (1N4004 is included in the packing)
4-
–
Access Control Power Supply
Programming
Programming will be varied depending on access configuration. Follow the instructions according to your access configuration.
Notes: > User ID number: Assign a user ID to the access card / PIN in order to track it.
The Common User ID PIN/ Card user ID: 0 ~ 989 Visitor User ID: 990 ~ 999
IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID is critical. Modifications to the user require the User ID be available.
> Proximity Card:
Proximity Card: 125KHz EM card or 13.56MHz Mifare card >PIN:
Can be any 4~6 digits except 8888 which is reserved. Press PIN on the Infrared Remote Control.
Add Common Users
PIN/ Card user ID: 0989; PIN length: 46 digits except 8888
5-
–
Programming Step
Keystroke Combination
1. Enter Program Mode
·k (Master Code) #
Add Card User
1 (ReadCard)/(Input 8/10/17Digits
2. Using Auto ID
Card Number)#
(Allows the device to assign Card to next The cards can be added continuously.
available User ID number)
OR
1 (User ID) # (Read Card) / (Input
2. Select Specific ID (Allows Master to
8/10/17 Digits Card Number) #
define a specific User ID to associate
the card to)
OR
1 (User ID) # (Card Quantity) # (The
2. Add Card: Block Enrollment (Allows
First Card 8/10/17 Digits Number)
Master to add up to 988 cards to the #
Reader in a single step) Takes 2
Cards’ number must be consecutive;
minutes to program.
(Card quantity is the number of cards to
be enrolled)
Add PIN User
2. Using Auto ID
1 (PIN)#
(Allows the device to assign PIN to next
available User ID number)
The PINs can be added continuously 1
OR
2. Select Specific ID (Allows manager to
define a specific User ID to associate (User ID)# (PIN)#
the PIN to)
3. Exit
*
Tips for PIN Security (Only valid for 6 digits PIN):
For higher security we allow you to hide your correct PIN with other numbers up to a max of 10 digits.
Example PIN: 123434 You could use **(123434) ** or ** (123434) (“*” can be any numbers from 09)
6-
–
Add Visitor Users
(User ID number is 990999; PIN length: 46 digits except 8888) There are 10 groups Visitor PIN/card available, the users can be specified up to 10 times of usage, after a certain number of times, i.e. 5 times, the PIN/card become invalid automatically.
Programming Step
Keystroke Combination
1. Enter Program Mode
(Master Code) #
2. Add Card
OR
2. Add PIN
1 (User ID) # (0~9) # (Read Card) / (Input 8/10/17 Digits Card Number)#
1 (UserlD)#(0~9)#(PIN)#
(09 means times of usage, 0=1 times)
3. Exit
*
Change PIN Users(PIN length: 46 digits except 8888)
Programming Step
Keystroke Combination
Note: Below is done outside programming mode, users can undertake this themselves
Change PIN
* (User ID) # (Old PIN) # (New PIN) # (Repeat New PIN) #
Change PIN of Card + PIN access *(Read Card) (Old PIN) # (New PIN) # mode (There will auto allocate PIN (Repeat New PIN) #
(8888) to cards when adding)
Delete Users
Programming Step
1. Enter Program Mode 2. Delete User- By
Card/PIN
OR
2. Delete User – By ID number
OR
2. Delete User – By Card number
OR
2. Delete ALL Users
3. Exit
Keystroke Combination ·k (Master Code) # 2 (Read Card)/(lnput PIN) #
The users can be deleted continuously.
2 (User ID)#
2 (input 8/10/17 Digits Card Number)# 2 (Master Code) #
*
7-
–
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
Programming Step
Keystroke Combination
1. Enter Program Mode
(Master Code) #
2. Pulse Mode OR
2. Toggle Mode
3. Exit
3 (1 99) # (factory default)
The relay time is 1-99 seconds. (Default is 5 seconds) 30# Sets the relay to ON/OFF Toggle mode
*
Set Access Mode
For Multi user access mode, the interval time of reading can not exceed 5 seconds, or else, the device will exit to standby automatically.
Programming Step
Keystroke Combination
1. Enter Program Mode
2 Card Access OR 2 PIN Access OR 2 Card + PIN Access OR 2 Card or PIN Access OR
2 Multi User Access
(Master Code) #
40# 41 # 42# 4 3# (factory default)
3. Exit
4 3 (2~9) #
(Only afier 29 valid users, the door can be opened)
*
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed entry attempts (Factory is OFF). It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid card/PIN or Master code / card.
08
—
Programming Step
1. Enter Program Mode
2. Strike-Out OFF OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set Alarm Time
3. Exit
Keystroke Combination ·k (Master Code) # 6 0# (factorydefault)
61# Access will be denied for 10 minutes (Exit button is still workable)
62# 5 (0 ~ 3) # (factory default is 1 minute) Enter
Master Code # or Master Card or valid user card/ PIN to silence *
Set Audible and Visual Response
Programming Step
Keystroke Combination
1. Enter Program Mode
* (Master Code) #
2. Disable Sound
70#
Enable Sound
OR
2. LED Always OFF
LED Always ON
71# (factory default)
72# 7 3# (factory default)
3. Exit
*
WIEGAND MODE————————————————-Pass-through Mode
(The device Operates as a Wiegand Output Reader)
In this mode the device supports a Wiegand 26 bits output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bits input, and then the device will operate as a slave reader.
–
9
Wiring Diagram
Controller Mode
(The device Operates as a Controller)
It supports Wiegand 26/34 bits input (Automatic Identification), so an external Wiegand device with 26/34 bits output can be connected to the Wiegand input terminals on the device. Either an EM card reader (125 KHz) ora Mifare card reader (13.56MHz) can be connected to the device. Cards are required to be added at the external reader, except where an external EM card Reader is used, in this case cards can be added at either reader or controller.
Wiring Diagram
OTHERS ———————————————————
Users Operation & Reset to Factory Default -10-
> Open the door: Read valid card user or input valid PIN user# > Remove Alarm: Enter Master Code # or Master Card or valid card /
PIN user
> To reset to factory default & Add Master Card: Power off, press the Exit Button,
hold it and power on, there will be two beeps, then release the exit button, the LED light turns into yellow, then read any 125KHz EM card/ 13.56MHz Mifare card, the LED will turn into red, means reset to factory default successfully. Of the card reading, it is the Master Card.
Remarks:
® If no Master Card added, must press the Exit Button for at least 5 seconds before release.(this will make the previous registered Master Card invalid) © Reset to factory default, the user’s information is still retained.
Master Card Usage
Using Master Card to add and delete users
Add Card / PIN Users
1. Input (Master Card) 2. Input (Card) or (PIN#)
Repeat step 2 for additional users
3. Input (Master Card) again
Delete Card / PIN Users
1. Input (Master Card Twice within 5s) 2. Input (Card) or (PIN#)
Repeat step 2 for additional users
3. Input (Master Card) again
–
11
Simplified Instruction
Function Description
Operation
Enter the Programming Mode
Change the Master Code
Add Card User
Add PIN User
Delete User Exit from the Programming Mode
How to release the door
Card User PIN User
*- Master Code -# then you can do the
programming (123456 is the factory default master code)
0 – New Code – # – Repeat the New Code -#
(code: 6 digits)
1 – Read Card – #
(can add cards continuously)
1 -PIN-#
(The PIN is any 4~6 digits except 8888 which is reserved)(Input PIN on the Infrared Remote Control)
2 – Read Card – # 2 – P I N – #
*
Read Card
Input PIN #
Documents / Resources
![]() |
AuthorizID S8-BT Standalone Access Control [pdf] User Manual S7-BT, S8-BT, S8-BT Standalone Access Control, Standalone Access Control, Access Control |