AURA LIGHT Renett Ceiling Light

Product Usage Instructions
Overview:
The Tridonic 65W product offers different current and wattage settings depending on the configuration of Pin 1 and Pin 2.
Current and Wattage Settings:
| Pin 1 | Pin 2 | Current | Wattage A | Wattage B |
|---|---|---|---|---|
| ON | ON | 350mA | 35W | 57W |
| OFF | ON | 300mA | 30W | 50W |
| ON | OFF | 250mA | 25W | 42W |
| OFF | OFF | 200mA | 20W | 33W |
Saftey Instruction

- Please read the instruction manual before installation and keep it for future reference.
Intended use:
- The luminaire is meant for standard use in damp environments and in outdoors areas which are covered by roofs. The luminaire is unsuitable for corrosive atmospheres (e.g. swimming pools, intensive animal husbandry, tunnels).
- These instructions assume expert knowledge corresponding to a completed professional education as an electrician.
- Ensure that the luminaire is undamaged before installation and commissioning!
- Never work when voltage is present on the luminaire. Caution – Risk of fatal injury!
- The manufacturer is not liable for any damage caused by incorrect or unauthorized use or by non-observance of these instructions.
- Work on the luminaire (installation, maintenance, servicing, troubleshooting) may only be carried out by authorized electrician.
- DALI: Basic insulation between supply-and control terminals.
- Max 16 A per phase when through-wiring.
5-Year warranty policy
- Aura Light offers a 5-year warranty regarding manufacturing and material defects in products manufactured and/or sold by Aura Light, provided that the product information for the product in question in digital form via www.auralight.com or in physical form via printed mailings by Aura Light, refers to this warranty policy.

- The luminaire contains a control gear and a replaceable LED light source that shall only be replaced by manufacturer.
Technical information can be found @ www.auralight.com
Product Usage Instruction
- First disconnect the existing lighting system from the power supply! Then demount the existing gear tray.
- If possible, also remove the existing wiring harness to reduce weight.

- If possible, also remove the existing wiring harness to reduce weight.
- Install the first retrofit module. To do this, hang the module in the rail. If necessary, select the desired power.

- Connect the mains adapter to the existing mains voltage and the first retrofit module according to the connection diagram.

- Mount the 2nd module and select different phases if necessary (Ll/L2/L3).
- Press the locking device at the same time to insert the 1st module into the rail. When releasing the lock, the module must sit firmly in the rail and be flush. Observe the compatibility list! Afterwards, connect the power connection frommodule 1 to module 2.

- Press the locking device at the same time to insert the 1st module into the rail. When releasing the lock, the module must sit firmly in the rail and be flush. Observe the compatibility list! Afterwards, connect the power connection frommodule 1 to module 2.
- Install further modules step by step, observing the connection phases (Ll/L2/L3).
- Note: When using blind covers, additional extension cables (accessories) are required to connect the retrofit modules!
Techinal data
Luminaries per fuse type:

- Ambient temperature range: -200C bis +400C
- Voltage range: 230-240V / 50hz-60Hz 198-264 DC (note driver!)
- Efficiency: 0,90
- Lifetime (L80 BIO): IOO.OOOh
- Protection class: I P40
- Protection rating: IK08
- Protection class: 1
- Photometric data: Light emission: > max (depending on optics)
- SDCM: 3
- CRI: 80
- Lumen/W: 160/175
- Light colour: 4000K
More Info
- Aura Light AB, Box 8, 598 40 Vimmerby, Sweden
- Phone customer service +46 (0)20 32 30 30
- info@auralight.com
- www.auralight.com
Frequently Asked Questions
Q: How do I change the current and wattage settings?
A: To change the current and wattage settings, simply adjust the configuration of Pin 1 and Pin 2 according to the provided table.
Q: Can I exceed the recommended wattage for a specific current setting?
A: It is not recommended to exceed the specified wattage for each current setting to ensure proper functionality and longevity of the product.
Documents / Resources
![]() |
AURA LIGHT Renett Ceiling Light [pdf] Instructions GT-57, GT-50, GT-42, GT-33W, Renett Ceiling Light, Renett, Ceiling Light, Light |