LPCI-COM485 Official Acces I O Distributor and Integrator

ACCES I/O LPCI-COM485/8

Specifications:

  • Model: LPCI-COM485/8
  • Manufacturer: ACCES I/O Products Inc
  • Compatibility: IBM PC, PC/XT, PC/AT
  • Warranty: 3 years for repairs and replacements
  • Manufacturer’s Address: 10623 Roselle Street, San Diego, CA
    92121

Product Usage Instructions:

1. Safety Precautions:

Always connect and disconnect field cabling with the computer
power off. Turn off computer power before installing the card to
avoid damage and warranty void.

2. Installation:

Refer to Chapter 2 of the user manual for detailed installation
instructions.

3. Option Selection:

For different options and configurations, refer to Chapter 3 of
the user manual.

FAQ:

Q: What should I do if the equipment fails?

A: In case of equipment failure, contact ACCES for prompt
service and support. The equipment is covered under warranty for
repairs and replacements.

Q: How long is the warranty period?

A: The warranty period is three years for repairs and
replacements. Additional service is available throughout the
equipment’s lifetime at reasonable rates.

Q: Can I install the card with the computer power on?

A: No, always ensure the computer power is off before installing
or connecting the card to avoid damage and warranty void.

“`

ACCES I/O LPCI-COM422-8 Get Quote
10623 Roselle Street, San Diego, CA 92121 · 858-550-9559 · FAX 858-550-7322 contactus@accesio.com · www.accesio.com
MODEL LPCI-COM485/8 USER MANUAL

FILE: MLPCI-COM485-8.E1l

www.assured-systems.com | sales@assured-systems.com

Page 1/25

ACCES I/O LPCI-COM422-8 Get Quote

Notice
The information in this document is provided for reference only. ACCES does not assume any liability arising out of the application or use of the information or products described herein. This document may contain or reference information and products protected by copyrights or patents and does not convey any license under the patent rights of ACCES, nor the rights of others.
IBM PC, PC/XT, and PC/AT are registered trademarks of the International Business Machines Corporation.
Printed in USA. Copyright 2001, 2006 by ACCES I/O Products Inc, 10623 Roselle Street, San Diego, CA 92121. All rights reserved.
WARNING!!
ALWAYS CONNECT AND DISCONNECT YOUR FIELD CABLING WITH THE COMPUTER POWER OFF. ALWAYS TURN COMPUTER POWER
OFF BEFORE INSTALLING A CARD. CONNECTING AND DISCONNECTING CABLES, OR INSTALLING CARDS INTO A SYSTEM WITH THE COMPUTER OR FIELD POWER ON MAY CAUSE DAMAGE TO THE I/O CARD AND WILL VOID ALL WARRANTIES, IMPLIED OR
EXPRESSED.

2
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 2/25

ACCES I/O LPCI-COM422-8 Get Quote
Warranty
Prior to shipment, ACCES equipment is thoroughly inspected and tested to applicable specifications. However, should equipment failure occur, ACCES assures its customers that prompt service and support will be available. All equipment originally manufactured by ACCES which is found to be defective will be repaired or replaced subject to the following considerations.
Terms and Conditions
If a unit is suspected of failure, contact ACCES’ Customer Service department. Be prepared to give the unit model number, serial number, and a description of the failure symptom(s). We may suggest some simple tests to confirm the failure. We will assign a Return Material Authorization (RMA) number which must appear on the outer label of the return package. All units/components should be properly packed for handling and returned with freight prepaid to the ACCES designated Service Center, and will be returned to the customer’s/user’s site freight prepaid and invoiced.
Coverage
First Three Years: Returned unit/part will be repaired and/or replaced at ACCES option with no charge for labor or parts not excluded by warranty. Warranty commences with equipment shipment.
Following Years: Throughout your equipment’s lifetime, ACCES stands ready to provide on-site or in-plant service at reasonable rates similar to those of other manufacturers in the industry.
Equipment Not Manufactured by ACCES
Equipment provided but not manufactured by ACCES is warranted and will be repaired according to the terms and conditions of the respective equipment manufacturer’s warranty.
General
Under this Warranty, liability of ACCES is limited to replacing, repairing or issuing credit (at ACCES discretion) for any products which are proved to be defective during the warranty period. In no case is ACCES liable for consequential or special damage arriving from use or misuse of our product. The customer is responsible for all charges caused by modifications or additions to ACCES equipment not approved in writing by ACCES or, if in ACCES opinion the equipment has been subjected to abnormal use. “Abnormal use” for purposes of this warranty is defined as any use to which the equipment is exposed other than that use specified or intended as evidenced by purchase or sales representation. Other than the above, no other warranty, expressed or implied, shall apply to any and all such equipment furnished or sold by ACCES.

3
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 3/25

ACCES I/O LPCI-COM422-8 Get Quote
Table of Contents
Chapter 1: Introduction……………………………………………………………………………………. 5 Specifications ……………………………………………………………………………………………… 7
Figure 1-1: Block Diagram (only one serial channel shown)……………………………………………………… 8
Chapter 2: Installation……………………………………………………………………………………… 9 Chapter 3: Option Selection …………………………………………………………………………… 11
Figure 3-1: Simplified Termination Schematic ………………………………………………………………………. 11 Figure 3-2: Low-Profile Model Option Selection Map……………………………………………………………… 13
Chapter 4: Address Selection ………………………………………………………………………… 14 Chapter 5: Programming ……………………………………………………………………………….. 15
Table 5-1: Baud Rate Divisor Values……………………………………………………………………………………. 16
Chapter 6: Connector Pin Assignments………………………………………………………….. 19
Table 6-1: Connector Pin Assignments ………………………………………………………………………………… 19 Table 6-2: Data Cable Wiring ……………………………………………………………………………………………… 20
Appendix A: Application Considerations………………………………………………………… 21
Table A-1: Connections Between Two RS422 Devices ………………………………………………………….. 21 Table A-2: RS422 Specification Summary ……………………………………………………………………………. 22 Figure A-1: Typical RS485 Two-Wire Multidrop Network ……………………………………………………….. 23

4
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 4/25

ACCES I/O LPCI-COM422-8 Get Quote
Chapter 1: Introduction
The card was designed for effective multipoint transmission in RS485 (EIA485) protocol. The card is 6.60 inches long and may be installed in an available 5V or 3.3V PCI expansion slot. The card features eight independent, asynchronous RS485 serial ports, type 16550 buffered UARTs, and, for Windows compatibility, automatic control to transparently enable/disable the transmission drivers. The card meets Universal PCI and MD2 Low Profile PCI Bus Specifications.
RS485 Balanced Mode Operation
The card supports RS485 communications and uses differential balanced drivers for long range and noise immunity. RS485 operation involves switchable transceivers and the ability to support multiple devices on a single “party line”. The RS485 specification defines a maximum of 32 devices on a single line. The number of devices served on a single line can be expanded by use of “repeaters”.
This card also has the capability to add load resistors to terminate the communications lines. RS485 communications requires that one transmitter supply a bias voltage to ensure a known “zero” state when all transmitters are off. Also, receiver inputs at each end of the network should be terminated to eliminate “ringing”. The card supports biasing by default and supports termination by jumpers on the card. If your application requires the transmitter to be un-biased, please contact the factory.
COM Port Compatibility
Type 16550 UARTs are used as the Asynchronous Communication Element (ACE). These include 16byte transmit/receive buffers to protect against lost data in multitasking operating systems, while maintaining 100 percent compatibility with the original IBM serial port. The system assigns the address(es).
A crystal oscillator is located on the card. This oscillator permits precise selection of baud rate up to 115,200 or, by changing a jumper, up to 921,600 with the standard crystal oscillator.
The driver/receiver used, the SN75176B, is capable of driving extremely long communication lines at high baud rates. It can drive up to +60 mA on balanced lines and receive inputs as low as 200 mV differential signal superimposed on common mode noise of +12 V or -7 V. In case of communication conflict, the driver/receivers feature thermal shutdown.
Communication Mode
This card supports Half-Duplex communications with a 2-wire cable connection. Half-Duplex allows traffic to travel in both directions, but only one way at a time. RS485 communications commonly use the HalfDuplex mode since they share only a single pair of wires.
Baud Rate Ranges
The card has capability for two baud rate ranges and you can select which you wish to use on a port-byport basis. One range is up to 115,200 baud applications and the other is up to 921,600 baud. Refer to Table 5-1, Baud Rate Divisor Values in chapter 5 of the manual.

5
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 5/25

ACCES I/O LPCI-COM422-8 Get Quote
Auto-RTS Transceiver Control
In RS485 communications, the driver must be enabled and disabled as needed, allowing all cards to share a two wire cable. The card controls the driver automatically. With automatic control, the driver is enabled when data is ready to be transmitted. The driver remains enabled for one additional character’s transmission time after data transfer is complete and then is disabled. The receiver is also normally enabled, then disabled during RS485 transmissions, and then re-enabled after transmission is completed (plus one character transmission time). The card automatically adjusts its timing to the baud rate of the data. (NOTE: Thanks to the automatic control feature, the card is ideal for use in Windows applications)

6
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 6/25

ACCES I/O LPCI-COM422-8 Get Quote

Specifications

Communications Interface

·

I/O Connection:

50 Pin SCSI D-Connector

·

Serial Ports:

Eight cable terminated shielded male D-sub 9-pin

connectors with standard IBM AT connectors compatible

with RS485 specifications

·

Character length:

5, 6, 7, or 8 bits.

·

Parity:

Even, odd or none.

·

Stop Interval:

1, 1.5, or 2 bits.

·

Serial Data Rates:

Up to 115,200 baud, Asynchronous, A faster range of

rates, up to 921,600, is achieved by jumper selection on

the card. Type 16550 buffered UART.

·

Address:

Continuously mappable within 0000 to FFFF (hex) range

of PCI bus addresses.

·

Receiver Input Sensitivity:

+200 mV, differential input.

·

Common Mode Rejection: +12V to -7V

·

Transmitter Output Drive Capability: 60 mA, with thermal shutdown.

Environmental

·

Operating Temperature Range: 0 °C. to +60 °C.

·

Storage temperature Range: -50 °C. to +120 °C.

·

Humidity:

5% to 95%, non-condensing.

·

Power Required:

+5VDC at 200 mA typical

·

Size:

Low Profile Version: 6.6″ long (167.64mm) by 2.21″

tall (56.17mm) seated height. Note The 16550 UART uses a 16-byte first-in-first-out buffer which is programmed through commands sent to the FIFO control register.

7
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 7/25

ACCES I/O LPCI-COM422-8 Get Quote
Figure 1-1: Block Diagram (only one serial channel shown)

8
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 8/25

ACCES I/O LPCI-COM422-8 Get Quote

Chapter 2: Installation

A printed Quick-Start Guide (QSG) is packed with the card for your convenience. If you’ve already performed the steps from the QSG, you may find this chapter to be redundant and may skip forward to begin developing your application.
The software provided with this card is on CD and must be installed onto your hard disk prior to use. To do this, perform the following steps as appropriate for your operating system.
Configure Card Options via Jumper Selection
Before installing the card into your computer, carefully read Chapter 3: Option Selection of this manual, then configure the card according to your requirements and protocol (RS-232, RS-422, RS-485, 4-wire 485, etc.). Our Windows based setup program can be used in conjunction with Chapter 3 to assist in configuring jumpers on the card, as well as provide additional descriptions for usage of the various card options (such as termination, bias, baud rate range, RS-232, RS-422, RS-485, etc.).
CD Software Installation

The following instructions assume the CD-ROM drive is drive “D”. Please substitute the appropriate drive letter for your system as necessary.

DOS 1.
2.
3. 4.

Place the CD into your CD-ROM drive. Type B- to change the active drive to the CD-ROM drive. Type GLQR?JJ- to run the install program. Follow the on-screen prompts to install the software for this board.

WINDOWS 1. Place the CD into your CD-ROM drive. 2. The system should automatically run the install program. If the install program does not run
promptly, click START | RUN and type BGLQR?JJ, click OK or press -. 3. Follow the on-screen prompts to install the software for this board.

LINUX 1. Please refer to linux.htm on the CD-ROM for information on installing under linux.

Note: COM boards can be installed in virtually any operating system. We do support installation in earlier versions of Windows, and are very likely to support future versions as well.

Caution! * ESD A single static discharge can damage your card and cause premature failure! Please follow all reasonable precautions to prevent a static discharge such as grounding yourself by touching any grounded surface prior to touching the card.

9
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 9/25

ACCES I/O LPCI-COM422-8 Get Quote
Hardware Installation
Make sure to set switches and jumpers from either the Option Selection section of this manual or from the suggestions of SETUP.EXE. 1. Do not install card into the computer until the software has been fully installed. 2. Turn OFF computer power AND unplug AC power from the system. 3. Remove the computer cover. 4. Carefully install the card in an available 5V or 3.3V PCI expansion slot (you may need to remove
a backplate first). 5. Inspect for proper fit of the card and tighten screws. Make sure that the card mounting bracket is
properly screwed into place and that there is a positive chassis ground. 6. Install an I/O cable onto the card’s bracket mounted connector. 7. Replace the computer cover and turn ON the computer. Enter the CMOS setup program of your
system and verify that the PCI plug-and-play option is set appropriately for your system. Systems running Windows 95/98/2000/XP/2003 (or any other PNP-compliant operating system) should set the CMOS option to OS. Systems running under DOS, Windows NT, Windows 3.1, or any other non-PNP-compliant operating system should set the PNP CMOS option to BIOS or Motherboard. Save the option and continue booting the system. 8. Most computers should auto-detect the card (depending on the operating system) and automatically finish installing the drivers. 9. Run PCIfind.exe to complete installing the card into the registry (for Windows only) and to determine the assigned resources. 10. Run one of the provided sample programs that was copied to the newly created card directory (from the CD) to test and validate your installation.
The base address assigned by BIOS or the operating system can change each time new hardware is installed into or removed from the computer. Please recheck PCIFind or Device Manager if the hardware configuration is changed. Software you write can automatically determine the base address of the card using a variety of methods depending on the operating system. In DOS, the PCISOURCE directory shows the BIOS calls used to determine the address and IRQ assigned to installed PCI devices. In Windows, the Windows sample programs demonstrate querying the registry entries (created by PCIFind and NTIOPCI.SYS during boot-up) to determine this same information.

10
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 10/25

ACCES I/O LPCI-COM422-8 Get Quote

Chapter 3: Option Selection
To help you locate the jumpers described in this section, refer to the Option Selection Map at the end of this section. Operation of the serial communications section is determined by jumper installation as described in the following paragraphs.

Terminations

Tx+/R x+

“A” through “H”

120
0.1 :F

Tx-/R x-
Figure 3-1: Simplified Termination Schematic A transmission line should be terminated at the receiving end in its characteristic impedance. Installing a jumper at the locations labeled LOAD OUTPUT applies a 120 load across the transmit/receive input/output for RS485 operation.
In RS485 operations where there are multiple terminals, only the RS485 ports at each end of the network should have terminating impedance as described above. To so terminate the COM A port, place a jumper at the location labeled LOAD OUTPUT A. To terminate the COM B, COM C, COM D, COM E, COM F, COM G and COM H ports, place jumpers at locations labeled B through H respectively.
Also, for RS485 operation, there must be a bias on the TRX+ and TRX- lines. If the card is not to provide that bias, contact the factory technical support.

11
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 11/25

ACCES I/O LPCI-COM422-8 Get Quote

Data Cable Wiring

SignalPin Connection

Ain-

1

Aout+

2

Aout-

3

100 to Ground

5

Ain+

9

Baud Rate Ranges
The jumper labeled X8CLK is provided to select baud rates in either of two ranges. When not installed, the baud rate range is up to 115,200 baud. When installed in the X8CLK, the baud rate range is 200 to 921,600 baud.

Interrupts
Please note that, in WindowsNT, changes must be made to the system registry to support IRQ sharing. The following is excerpted from “Controlling Multiport Serial I/O Cards” provided by Microsoft in the MSDN library, documentid:mk:@ivt:nt40res/D15/S55FC.HTM, also available in the WindowsNT Resource Kit.

The Microsoft serial driver can be used to control many dumb multiport serial cards. Dumb indicates that the control includes no on-board processor. Each port of a multiport card has a separate subkey under the HKLMCurrentControlSetServicesSerial subkey in the registry. In each of these subkeys, you must add values for DosDevices, Interrupt, InterruptStatus, PortAddress, and PortIndex because these are not detected by the Hardware Recognizer. (For descriptions and ranges for these values, see Regentry.hlp, the Registry help file on the WindowsNT Workstation Resource Kit CD.)

For example, if you have an eight-port card configured to use address 0xFC00 with an interrupt of 05, the values in the Registry are:

Serial2 Subkey: PortAddress = REG_DWORD 0xFC00 Interrupt = REG_WORD 5 DosDevices = REG_SZ COM5 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 1 Indexed = 0 Serial3 Subkey: PortAddress = REG_DWORD 0xFC08 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM6 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 2 Indexed = 0 Serial4 Subkey: PortAddress =_DWORD 0xFC10 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM7 InterruptStatus = REG_DWORD 0xFC40 PortIndex – REG_DWORD 3 Indexed = 0 Serial5 Subkey: PortAddress = REG_DWORD 0xFC18 Interrupt = REG_DWORD 5 Dos Devices = REG_SZ COM8 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD4 Indexed = 0

Serial6 Subkey: PortAddress = REG_DWORD 0xFC20 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM9 InterruptStatus = REG_DWORD 0xFC40 PortIndex – REG_DWORD 5 Indexed = 0 Serial7 Subkey: PortAddress = REG_DWORD 0xFC28 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM10 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 6 Indexed = 0 Serial8 Subkey: PortAddress = REG_DWORD 0xFC30 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM11 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD 7 Indexed = 0 Serial9 Subkey: PortAddress = REG_DWORD 0xFC38 Interrupt = REG_DWORD 5 DosDevices = REG_SZ COM12 InterruptStatus = REG_DWORD 0xFC40 PortIndex = REG_DWORD8 Indexed = 0

12

Manual LPCI-COM485-8

www.assured-systems.com | sales@assured-systems.com

Page 12/25

ACCES I/O LPCI-COM422-8 Get Quote

Figure 3-2: Low-Profile Model Option Selection Map

13
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 13/25

ACCES I/O LPCI-COM422-8 Get Quote
Chapter 4: Address Selection
The card uses one address space. COM A, COM B, COM C, COM D, COM E, COM F, COM G and COM H each occupy eight consecutive register locations. The interrupt register which indicates which port or ports caused the interrupt is located at base address + 64.
PCI architecture is Plug and Play. This means that the BIOS or Operating System determines the resources assigned to PCI cards rather than you selecting those resources with switches or jumpers. As a result, you cannot set or change the card’s base address. You can only determine what the system has assigned.
To determine the base address that has been assigned, run the PCIFind.EXE, or PCINT utility program provided. This utility will display a list of all of the cards detected on the PCI bus, the addresses assigned to each function on each of the cards, and the respective IRQs (if any) allotted.
Alternatively, some operating systems (Plug and Play Windows) can be queried to determine which resources were assigned. In these operating systems, you can use either PCIFind or the Device Manager utility from the System Applet of the control panel. The card is installed in the Data Acquisition class of the Device Manager list. Selecting the card, clicking Properties, and then selecting the Resources Tab will display a list of the resources allocated to the card.
The PCI bus supports 64K of I/O space. Your card’s addresses may be located anywhere in the 0000 to FFFF hex range.
PCIFind uses the Vendor ID and Device ID to search for your card, then reads the base address and IRQ.
If you want to determine the base address and IRQ yourself, use the following information.
The Vendor ID for the card is 494F. (ASCII for “IO”) The Device ID for the card is 1069h.

14
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 14/25

ACCES I/O LPCI-COM422-8 Get Quote
Chapter 5: Programming
Sample Programs
There are sample programs provided with the card in C, Pascal, QuickBASIC, and several Windows languages. DOS samples are located in the DOS directory and Windows samples are located in the WIN32 directory.
Windows Programming
The card installs into Windows as COM ports. Thus the Windows standard API functions can be used. In particular:
CreateFile() and CloseHandle() for opening and closing a port. SetupComm(), SetCommTimeouts(), GetCommState(), and SetCommState() to set and
change a port’s settings. ReadFile() and WriteFile() for accessing a port. See the documentation for your chosen language for details. Under DOS, the process is very different. The remainder of this chapter describes DOS programming.

15
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 15/25

ACCES I/O LPCI-COM422-8 Get Quote

Initialization
Initializing the chip requires knowledge of the UART’s register set. The first step is to set the baud rate divisor. You do this by first setting the DLAB (Divisor Latch Access Bit) high. This bit is Bit 7 at Base Address +3. In C code, the call would be:
outportb(BASEADDR +3,0×80);
You then load the divisor into Base Address +0 (low byte) and Base Address +1 (high byte). The following equation defines the relationship between baud rate and divisor:
desired baud rate = (UART Clock Frequency) / (32 * divisor)
On the card, the UART clock frequency is 1.8432 MHz. Below is a table for the popular divisor frequencies.

Baud Rate 921600 460800 230400 153600 115200 57600 38400 28800 19200 14400 9600 4800 2400 1200

Divisor x1 1 2 3 4 6 8 12 24 48 96

Divisor x8 1 2 4 6 8 16 24 32 48 64 96 ­ Most Common 192 384 768

Max Diff. Cable Length* 250 ft 550 ft 1400 ft 2500 ft 3000 ft 4000 ft 4000 ft 4000 ft 4000 ft 4000 ft 4000 ft 4000 ft 4000 ft 4000 ft

*These are theoretical maximums based on typical conditions and good quality cables based on the EIA 485 and EIA 422 standard
for balanced differential drivers.
Table 5-1: Baud Rate Divisor Values
In C, the code to set the chip to 9600 baud is:
outportb(BASEADDR +3, 0X80);// enters baud-divisor setup mode outportb(BASEADDR, 0x0C); outportb(BASEADDR +1,0);

16
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 16/25

ACCES I/O LPCI-COM422-8 Get Quote

The second initializing step is to set the Line Control Register at Base Address +3. This register defines word length, stop bits, parity, and the DLAB.
Bits 0 and 1 control word length and allow word lengths from 5 to 8 bits. Bit settings are extracted by subtracting 5 from the desired word length.
Bit 2 determines the number of stop bits. There can be either one or two stop bits. If Bit 2 is set to 0, there will be one stop bit. If Bit 2 is set to 1, there will be two stop bits.
Bits 3 through 6 control parity and break enable. They are not commonly used for communications and should be set to zeroes.
Bit 7 is the DLAB discussed earlier. It must be set to zero after the divisor is loaded or else there will be no communications.
The C command to set the UART for an 8-bit word, no parity, and one stop bit is:
outportb(BASEADDR +3, 0x03)
The final initialization step is to flush the receiver buffers. You do this with two reads from the receiver buffer at Base Address +0. When done, the UART is ready to use.

Reception

Reception can be handled in two ways: polling and interrupt-driven. When polling, reception is accomplished by constantly reading the Line Status Register at Base Address +5. Bit 0 of this register is set high whenever data are ready to be read from the chip. A simple polling loop must continuously check this bit and read in data as it becomes available. The following code fragment implements a polling loop and uses a value of 13, (ASCII Carriage Return) as an end-of-transmission marker:

do { while (!(inportb(BASEADDR +5) & 1)); data[i++]= inportb(BASEADDR); } while (data[i]!=13);

/*Wait until data ready*/ /*Reads the line until null character rec’d*/

Interrupt-driven communications should be used whenever possible and is required for high data rates. Writing an interrupt-driven receiver is not much more complex than writing a polled receiver but care should be taken when installing or removing your interrupt handler to avoid writing the wrong interrupt, disabling the wrong interrupt, or turning interrupts off for too long a period.

The handler would first read the Interrupt Identification Register at Base Address +2. If the interrupt is for Received Data Available, the handler then reads the data. If no interrupt is pending, control exits the routine. A sample handler, written in C, is as follows:

readback = inportb(BASEADDR +2);

if (readback & 4)

/*Readback will be set to 4 if data are available*/

data[i++]=inportb(BASEADDR);

outportb(0x20,0x20);

/*Write EOI to 8259 Interrupt Controller*/

return;

17
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 17/25

ACCES I/O LPCI-COM422-8 Get Quote

Transmission

RS485 transmission is simple to implement. The AUTO feature of the card automatically enables the transmitter when data is ready to send so no software enabling is required. The following software example is for non-AUTO operation.

To transmit a string of data, the transmitter must first check Bit 5 of the Line Status Register at Base Address +5. That bit is the transmitter-holding-register-empty flag. If it is high, the transmitter has sent the data. The process of checking the bit until it goes high followed by a write is repeated until no data remains.

The following C code fragment demonstrates this process:

outportb(BASEADDR +4, inportb(BASEADDR +4)|0x02);

/*Set RTS bit without altering states of other bits*/

while(data[i]);

/*While there is data to send*/

{

while(!(inportb(BASEADDR +5)&0x20)); /*Wait until transmitter is empty*/

outportb(BASEADDR,data[i]);

i++;

}

outportb(BASEADDR +4, inportb(BASEADDR +4)&0xFD);

/*Reset RTS bit without altering states of other bits*/

18
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 18/25

ACCES I/O LPCI-COM422-8 Get Quote

Chapter 6: Connector Pin Assignments

Input/Output Connections
The card uses a 50-pin SCSI D-connector to interface to a spider cable. The spider cable has eight individual DB9M connectors provided with it.
To ensure that there is minimum susceptibility to EMI and minimum radiation, it is important that the card mounting bracket be properly screwed into place and that there be a positive chassis ground. Also, proper EMI cabling techniques (cable connect to chassis ground at the aperture, shielded twisted-pair wiring, etc) be used for the input/output wiring.

PIN Number Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 Pin 10 Pin 11 Pin 12 Pin 13 Pin 14 Pin 15 Pin 16 Pin 17 Pin 18 Pin 19 Pin 20 Pin 21 Pin 22 Pin 23 Pin 24 Pin 25

RS-485 Signals Pin Number

GND Ground

Pin 26

Ain/out+

Pin 27

Ain/out-

Pin 28

GND thru 100 Ohm Pin 29

Unused

Pin 30

Unused

Pin 31

GND Ground

Pin 32

Bin/out+

Pin 33

Bin/out-

Pin 34

GND thru 100 Ohm Pin 35

Unused

Pin 36

Unused

Pin 37

GND Ground

Pin 38

Cin/out+

Pin 39

Cin/out-

Pin 40

GND thru 100 Ohm Pin 41

Unused

Pin 42

Unused

Pin 43

GND Ground

Pin 44

Din/out+

Pin 45

Din/out-

Pin 46

GND thru 100 Ohm Pin 47

Unused

Pin 48

Unused

Pin 49

GND Ground

Pin 50

RS-485 Signals GND Ground Ein/out+ Ein/outGND thru 100 Ohm Unused Unused GND Ground Fin/out+ Fin/outGND thru 100 Ohm Unused Unused GND Ground Gin/out+ Gin/outGND thru 100 Ohm Unused Unused GND Ground Hin/out+ Hin/outGND thru 100 Ohm Unused Unused GND Ground

Table 6-1: Connector Pin Assignments

19
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 19/25

ACCES I/O LPCI-COM422-8 Get Quote

Signal Unused Ain/out+ Ain/outUnused

Connector Pin Pin 1 Pin 2 Pin 3 Pin 4

100 Ohm to Ground Pin 5

Unused

Pin 6

Unused

Pin 7

Unused

Pin 8

Unused

Pin 9

Table 6-2: Data Cable Wiring

20
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 20/25

ACCES I/O LPCI-COM422-8 Get Quote

Appendix A: Application Considerations

Introduction
Working with RS422 and RS485 devices is not much different from working with standard RS232 serial devices and these two standards overcome deficiencies in the RS232 standard. First, the cable length between two RS232 devices must be short; less than 50 feet at 9600 baud. Second, many RS232 errors are the result of noise induced on the cables. The RS422 standard permits cable lengths up to 5000 feet and, because it operates in the differential mode, it is more immune to induced noise.
Connections between two RS422 devices (with CTS ignored) should be as follows:

Device #1

Device #2

Signal Pin No. Signal Pin No.

Gnd

7

Gnd

7

TX+

24

RX+

12

TX-

25

RX-

13

RX+

12

TX+

24

RX-

13

TX-

25

Table A-1: Connections Between Two RS422 Devices

A third deficiency of RS232 is that more than two devices cannot share the same cable. This is also true for RS422 but RS485 offers all the benefits of RS422 plus allows up to 32 devices to share the same twisted pairs. An exception to the foregoing is that multiple RS422 devices can share a single cable if only one will talk and the others will all receive.

Balanced Differential Signals
The reason that RS422 and RS485 devices can drive longer lines with more noise immunity than RS232 devices is that a balanced differential drive method is used. In a balanced differential system, the voltage produced by the driver appears across a pair of wires. A balanced line driver will produce a differential voltage from +2 to +6 volts across its output terminals. A balanced line driver can also have an input “enable” signal that connects the driver to its output terminals. If the “enable signal is OFF, the driver is disconnected from the transmission line. This disconnected or disabled condition is usually referred to as the “tristate” condition and represents a high impedance. RS485 drivers must have this control capability. RS422 drivers may have this control but it is not always required.
A balanced differential line receiver senses the voltage state of the transmission line across the two signal input lines. If the differential input voltage is greater than +200 mV, the receiver will provide a specific logic state on its output. If the differential voltage input is less than -200 mV, the receiver will provide the opposite logic state on its output. A maximum operating voltage range is from +6V to -6V allows for voltage attenuation that can occur on long transmission cables.
A maximum common mode voltage rating of +7V provides good noise immunity from voltages induced on the twisted pair lines. The signal ground line connection is necessary in order to keep the common mode voltage within that range. The circuit may operate without the ground connection but may not be reliable.

21
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 21/25

ACCES I/O LPCI-COM422-8 Get Quote

Parameter Driver Output Voltage (unloaded)
Driver Output Voltage (loaded)
Driver Output Resistance Driver Output Short-Circuit Current Driver Output Rise Time Receiver Sensitivity Receiver Common Mode Voltage Range Receiver Input Resistance

Conditions

Min.

4V

-4V

LD and LDGND

2V

jumpers in

-2V

Max. 6V -6V
50 +150 mA 10% unit interval +200 mV +7V
4K

Table A-2: RS422 Specification Summary

To prevent signal reflections in the cable and to improve noise rejection in both the RS422 and RS485 mode, the receiver end of the cable should be terminated with a resistance equal to the characteristic impedance of the cable. (An exception to this is the case where the line is driven by an RS422 driver that is never “tristated” or disconnected from the line. In this case, the driver provides a low internal impedance that terminates the line at that end.)

Note You do not have to add a terminator resistor to your cables when you use the card. Termination resistors for the RX+ and RX- lines are provided on the card and are placed in the circuit when you install the LD and LDGND jumpers. (See the Option Selection section of this manual.)

RS485 Data Transmission
The RS485 Standard allows a balanced transmission line to be shared in a party-line mode. As many as 32 driver/receiver pairs can share a two-wire party line network. Many characteristics of the drivers and receivers are the same as in the RS422 Standard. One difference is that the common mode voltage limit is extended and is +12V to -7V. Since any driver can be disconnected (or tristated) from the line, it must withstand this common mode voltage range while in the tristate condition.
The following illustration shows a typical multidrop or party line network. Note that the transmission line is terminated on both ends of the line but not at drop points in the middle of the line.

22
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 22/25

ACCES I/O LPCI-COM422-8 Get Quote

Figure A-1: Typical RS485 Two-Wire Multidrop Network
RS485 Four-Wire Multidrop Network
An RS485 network can also be connected in a four-wire mode. In a four-wire network it’s necessary that one node be a master node and all others be slaves. The network is connected so that the master communicates to all slaves and all slaves communicate only with the master. This has advantages in equipment that uses mixed protocol communications. Since the slave nodes never listen to another slave’s response to the master, a slave node cannot reply incorrectly.

23
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 23/25

ACCES I/O LPCI-COM422-8 Get Quote
Customer Comments
If you experience any problems with this manual or just want to give us some feedback, please email us at: manuals@accesio.com. Please detail any errors you find and include your mailing address so that we can send you any manual updates.

10623 Roselle Street, San Diego CA 92121 Tel. (858)550-9559 FAX (858)550-7322 www.accesio.com

24
www.assured-systems.com | sales@assured-systems.com

Manual LPCI-COM485-8
Page 24/25

ACCES I/O LPCI-COM422-8 Get Quote
Assured Systems
Assured Systems is a leading technology company with over 1,500 regular clients in 80 countries, deploying over 85,000 systems to a diverse customer base in 12 years of business. We offer high-quality and innovative rugged computing, display, networking and data collection solutions to the embedded, industrial, and digital-out-of-home market sectors.
US
sales@assured-systems.com
Sales: +1 347 719 4508 Support: +1 347 719 4508
1309 Coffeen Ave Ste 1200 Sheridan WY 82801 USA
EMEA
sales@assured-systems.com
Sales: +44 (0)1785 879 050 Support: +44 (0)1785 879 050
Unit A5 Douglas Park Stone Business Park Stone ST15 0YJ United Kingdom
VAT Number: 120 9546 28 Business Registration Number: 07699660

www.assured-systems.com | sales@assured-systems.com

Page 25/25