ASIS technologies R385 Series Reader
Product Information
Specifications:
- Power Supply (Recommend): Regulated linear power supply, +12VDC, 300mA
- Operating Voltage Range: +9VDC – +24VDC
- Maximum Cable Distance: 150 meters (500 feet)
- Reader Module Dimension: 76.00mm x 21.00mm x 135.00mm
Reader Wiring and Color Code
Terminal Point Label | Description | Recommended Cable Color |
Dev+ | RS485+ | Yellow |
Dev- | RS485- | White |
+V | +12VDC | Red |
GND | DC Ground | Black |
Table 2 Wiring and Cable Color code
DIP Switch Setting
BIT | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Function (RS485) | ADDRESS BIT | MODE and Data Out BIT | n/a | |||||
bit 0 | bit 1 | bit 2 | bit 3 | RS485 | Off- 8 byte
On -4 byte |
Off – CSN On – CAN | n/a | |
Function (Wiegand) | Card format Setting |
Table 3 Dip Switch function explain
BIT | ||||||||
Reader | Hex address | 1 | 2 | 3 | 4 | 5 ~ 8 | ||
Function | 1 | 80 | Off | Off | Off | Off | Refer to | |
(RS485) | above | |||||||
2 | 81 | On | Off | Off | Off | |||
BIT | table | |||||||
3 | 82 | Off | On | Off | Off | |||
Address | ||||||||
4 | 83 | On | On | Off | Off | |||
5 | 84 | Off | Off | On | Off | |||
6 | 85 | On | Off | On | Off | |||
7 | 86 | Off | On | On | Off | |||
8 | 87 | On | On | On | Off |
Table 4 RS485 Readers Address Dip Switch Setting
Dimension
Reader Module Dimension
Installation And Mounting Instruction
Remove Bottom Screw
Ply open the front cover using flat head screw driver remove the front of the unit.
Remove the front of unit
Mark out reader base (reader wire pigtail) and (wall mounting hole) drill hole on the wall for mounting reader.
Half tighten wall mount screw.
Terminate reader pigtail cable to cable from controller. Tighten wall mount screw
Reinsert reader front to base by set the bottom. Align reader pigtail cable accordingly. Push to front top to snap into the base. | ![]() |
Tighten bottom screw | ![]() |
Operation Guide
Keeping the card in parallel to the R385 reader a maximum read range can be obtained. The Reader will still be able to read Card when the card is presented at an angle but this will result in the reducing of read range.
Card and PIN operation
- In Card & Pin mode LCD screen prompt to Enter Pin, enter PIN follow s by “#” key
- Key in PIN + 1 for PIN DURESS (Example PIN is 1234, for duress activation, key pin 1235)
Note that the maximum PIN is up to 6 digit.
Package List – R385 Reader
Item Description: Complete with snap on cover. 1 x Mounting cover security screw [M3], 1 x security screw driver, and this document.
Product Electrical Specification
Power Supply (Recommend) | Regulated linear power supply, +12VDC, 300mA |
Operating Voltage Range | +9VDC – + 24VDC |
Operating Current at +12VDC | 85mA (average) – 185mA (peak) |
Maximum Cable Distance |
150meters (500feet)
(base on Belden 9538 24AWG 0.6mm, 8 core cable foilshield) (for wiegand interface) (base on Belden 9534 24 AWG 0.6mm, 4 core cable foilshield) ( for RS485 interface ) |
Read Range |
<=50mm (2”)
( Read Range is dependent on local installation conditions ) |
Transmit Frequency | 13.56MHz |
LED | Tri Color – Red, Green, Amber |
Buzzer | Multi-tone |
Operating temperature Range | -20°C to 50°C |
Colour | Black |
Material | High Heat ABS |
Weight | 200 grams |
Dimension | 135mm (Height) X 76mm (Width) X 21mm (Thickness) |
Wire Termination | 9 conducting wire at length approx. 300mm |
Reader Mode | Card Only, Card and PIN. |
PIN Input | 1 – 6 Digits |
Keypad | 3 x 4 Keys |
Communication Interface | RS485 or Wiegand ( Selectable ) |
Wiegand interface Output bit
format |
26, 32, 37, 40, 56, 80, 168(Asis) bits format and
8-digit 32, 37, 40 bits format |
Support Card Type | Mifare ( ISO 14443-A, ISO 14443-B) |
EZ-Link | Output CAN or CSN (Selectable) |
Mounting | Reader back casing mount |
FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RF Exposure Information
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
Frequently Asked Questions
Q: What is the maximum PIN length for Card and PIN operation?
A: The maximum PIN length is up to 6 digits.