Introduction
Thank you for choosing the EUHOMY Portable Air Conditioner. This appliance is designed to provide comfort through its 4-in-1 functionality: cooling, dehumidification, fan, and sleep mode. Please read this manual thoroughly before operation to ensure proper use, maintenance, and safety.
Safety Information
Always follow basic safety precautions when using electrical appliances to reduce the risk of fire, electric shock, and injury.
- Ensure the power supply matches the voltage specified on the unit's rating label.
- Do not operate the unit with a damaged cord or plug.
- Keep the unit away from water and other liquids. Do not immerse the unit in water.
- Do not block air inlets or outlets. Maintain at least 30 cm clearance from walls and other objects.
- Unplug the unit before cleaning or performing any maintenance.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Use only the accessories provided or recommended by the manufacturer.
- Do not attempt to repair or modify the unit yourself. Contact qualified service personnel for repairs.
What's in the Box
Verify that all components are present upon unpacking:
- Portable Air Conditioner Unit
- Remote Control
- User Manual
- Window Kit Assembly
- Exhaust Hose
- Window Adapter
- Hose Connector
- Drainage Hose
- Wing Nuts and Screws

Setup and Installation
The EUHOMY Portable Air Conditioner is designed for easy setup and flexible use. It features integrated handles and casters for convenient movement between rooms.
Window Kit Installation
- Connect the window adapter to one end of the exhaust hose.
- Adjust the window kit assembly to fit your window opening (suitable for 43-135 cm). Secure it with screws if necessary.
- Attach the exhaust hose with the window adapter to the adjusted window kit.
- Connect the hose connector to the exhaust outlet on the back of the air conditioner unit.
- Connect the other end of the exhaust hose to the hose connector on the unit.


Operating Instructions
Your EUHOMY Portable Air Conditioner offers four operating modes and can be controlled via the LED touch screen panel or the included remote control.
Control Panel and Remote Control
The unit features an intuitive LED touch screen display on top and comes with a remote control for convenient operation from up to 7 meters away. The remote allows adjustment of temperature, timer, and fan speed.

Operating Modes
Select the desired mode using the 'Mode' button on the control panel or remote.
- Cooling Mode: Provides powerful cooling with 7000 BTU (2.0 kW) capacity. Set your desired temperature between 16°C and 32°C. Ideal for rooms up to 20 m².
- Dehumidification Mode: Removes excess moisture from the air, with a capacity of 50 pints per day.
- Fan Mode: Circulates air without cooling. Choose between low and high fan speeds.
- Sleep Mode: Operates quietly at less than 48 dB, gradually adjusting the temperature for comfortable sleep.

Additional Features
- 24-Hour Timer: Program the unit to turn on or off automatically.
- Child Safety Lock: Prevents accidental changes to settings.
- Adjustable Fan Blades: Manually adjust the direction of airflow.
Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your air conditioner.
Cleaning the Air Filter
The air filter is removable and washable. Clean it regularly (every two weeks or more often depending on usage) to maintain air quality and cooling efficiency.
- Unplug the air conditioner from the power outlet.
- Locate and remove the air filter from the unit.
- Wash the filter with warm water and a mild detergent. Rinse thoroughly.
- Allow the filter to air dry completely before reinserting it into the unit. Do not expose to direct sunlight.

Draining Water
During dehumidification or cooling in high humidity, water will accumulate in the internal tank. The unit has an indicator for water level. When full, the unit will stop operating and display an error code. Connect the drainage hose to the drainage port and place the other end into a suitable container or floor drain to empty the tank.
Troubleshooting
Before contacting customer support, please refer to the following common issues and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Unit does not turn on | No power supply; Power cord not plugged in; Fuse blown/Circuit breaker tripped | Check power outlet; Ensure plug is fully inserted; Reset circuit breaker or replace fuse. |
| Unit is not cooling effectively | Air filter is dirty; Room size too large; Doors/windows open; Exhaust hose not properly installed | Clean air filter; Ensure unit is suitable for room size (up to 20 m²); Close all doors and windows; Verify exhaust hose is securely connected and vented outside. |
| Unit is noisy | Unit not on a flat surface; Obstruction in fan; Normal operating sound | Place unit on a flat, stable surface; Check for and remove any obstructions; Some operating noise is normal for portable AC units. |
| Water leakage | Drainage hose not connected properly; Internal water tank full | Ensure drainage hose is securely attached; Drain the internal water tank. |
Product Specifications
| Brand | EUHOMY |
| Model Name | OL-A016FF20N2 |
| Cooling Capacity | 7000 BTU (British Thermal Unit) |
| Power (kW) | 2.0 kW |
| Special Features | Dehumidifier, Dust Filter |
| Product Dimensions (D x W x H) | 28P x 30.6W x 69.5H cm |
| Start Year | 2025 |
| Seasonal Energy Efficiency Ratio (SEER) | 4 |
| Color | White-417 |
| Voltage | 220 Volts |
| Noise Level | 64 Decibels (Operating), <48 Decibels (Sleep Mode) |
| Refrigerant | R-290 |
| Installation Type | Window |
| Compressor Type | Rotary Scroll |
| Power Source | Corded Electric |
| Wattage | 1385 Watts |
| Item Weight | 21.5 Kilograms |
| Max Window Opening Width | 135 Centimeters |
| Min Window Opening Height | 125 Centimeters |
| Min Window Opening Width | 43 Centimeters |
| Max Window Opening Height | 135 Centimeters |
| Floor Area Coverage | 700 Square Feet (approx. 20 m²) |
| Control Method | Push Button, Remote Control |
| Energy Efficiency Class | A |
| Annual Energy Consumption | 500 Kilowatt Hours per year |
| UPC | 850070202596 |
Warranty Information
The product comes with a Limited Warranty. For specific details regarding the terms and conditions of your warranty, please refer to the documentation included with your purchase or contact EUHOMY customer support.
Customer Support
If you encounter any issues not covered in the troubleshooting section or require further assistance, please contact EUHOMY customer support. Refer to your product packaging or the official EUHOMY website for contact details.
When contacting support, please have your model number (OL-A016FF20N2) and purchase information readily available.