1. Important Safety Instructions

Please read all instructions carefully before using this appliance and retain for future reference. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure the power supply voltage matches the rating label on the appliance.
  • Do not immerse the appliance, cord, or plug in water or other liquids.
  • Unplug from the outlet when not in use, before cleaning, or before moving.
  • Keep the appliance away from heat sources, direct sunlight, and flammable materials.
  • Do not operate with a damaged cord or plug, or after the appliance malfunctions or has been damaged in any manner.
  • This appliance is for indoor use only.
  • Do not block air inlets or outlets.
  • Keep out of reach of children.

2. Product Overview

The OEARE Portable Air Conditioner is a 3-in-1 unit combining air conditioning (with water and ice pack), humidifier (with water), and cooling fan functions. It features multiple modes, speeds, and a large water tank for extended operation.

Diagram showing 3-in-1 functions: Normal Fan, Humidifier, and Air Cooler with cold air output and hot air intake.

Figure 2.1: 3-in-1 Functionality (Fan, Humidifier, Air Cooler)

The unit operates as a normal fan without water, a humidifier when water is added, and an air cooler when both water and ice packs are used. It draws in hot air, passes it through a cooling medium, and expels cold air.

3. Setup and Installation

3.1 Unpacking

  • Carefully remove the appliance from its packaging.
  • Check for any damage during transit. If damaged, do not operate and contact customer support.
  • Ensure all accessories, including the remote control and 4 ice packs, are present.

3.2 Placement

Place the air conditioner on a flat, stable surface. This unit is designed for freestanding use and does not require any window kits, hoses, or drilling for installation.

Image showing the portable air conditioner plugged into a wall outlet, with icons indicating no hose, no drilling, and no window required.

Figure 3.1: Placement and Power Connection (No Hose, Drilling, or Window Required)

3.3 Filling the Water Tank

The unit features a 6L water tank with an upper and lower double water tank structure. It comes with 4 ice packs for enhanced cooling.

  1. Prepare Ice Packs: Place the included ice packs in a freezer until completely frozen.
  2. Access Bottom Tank: The bottom water tank is removable for easy cleaning and ice pack placement. Carefully pull out the bottom tank.
  3. Place Ice Packs: Place the frozen ice packs into the bottom water tank.
  4. Fill Top Tank: Open the lid on the top of the unit to access the top water tank. Slowly pour clean water into the top tank. Do not overfill; adding water too quickly may cause overflow.
  5. Reinsert Bottom Tank: Ensure the bottom tank is securely reinserted into the unit.
Four-step diagram showing how to use the cooling function: 1. Freeze ice packs, 2. Place ice packs in bottom tank, 3. Add water to top tank, 4. Turn on cooling mode.

Figure 3.2: Steps for Using the Cooling Function

Image showing a hand pouring water into the top of the air conditioner, with the 6L removable water tank and ice packs visible at the bottom.

Figure 3.3: Large Water Tank and Ice Pack System

4. Operating Instructions

The unit can be operated via the top control panel or the included remote control.

Image showing the top control panel of the air conditioner and a hand holding the remote control, demonstrating dual control options.

Figure 4.1: Control Panel and Remote Control

4.1 Power On/Off

  • Press the POWER button on the control panel or remote control to turn the unit on or off.

4.2 Adjusting Wind Speed

The unit offers 3 wind speeds: Low, Medium, and High.

  • Press the SPEED button repeatedly to cycle through the available wind speeds.

4.3 Selecting Operating Mode

Choose from 4 wind feeling modes: Normal, Natural, Sleep, and Cooling.

Diagram illustrating 4 modes (Cool, Normal, Natural, Sleep) and 3 wind speeds (Low, Medium, High) with airflow indicators.

Figure 4.2: 4 Modes and 3 Wind Speeds

  • Press the MODE button repeatedly to select the desired operating mode.
  • Normal Mode: Provides continuous strong wind.
  • Natural Mode: Simulates a gentle breeze.
  • Sleep Mode: Operates quietly for undisturbed sleep.
  • Cooling Mode: Activates the evaporative cooling function (requires water and ice packs).

4.4 Oscillation Function

The unit features automatic oscillation for wide air distribution.

Image showing the air conditioner oscillating, with indicators for 26ft/s max speed, 120 degree up and down adjust, and 35dB quiet air supply.

Figure 4.3: Wide Air Supply with Auto Oscillation

  • Press the SWING button to activate or deactivate the automatic oscillation feature. The unit provides 120-degree up and down adjustability.

4.5 Timer Function

Set the unit to automatically turn off after a specified period, up to 12 hours.

  • Press the TIMER button repeatedly to set the desired operating duration. The timer can be set in 1-hour increments.

4.6 Display Control

To avoid light disturbance, especially at night, the display can be turned off.

  • From Unit: Press and hold the FAN button on the device.
  • From Remote: Briefly press the DISPLAY button on the remote control.
Image showing the air cooler operating quietly in a bedroom with a sleeping couple, highlighting 12H timer, 35dB quiet operation, and no light display features.

Figure 4.4: Low Noise Operation and Closable Screen

5. Maintenance

Regular maintenance ensures optimal performance and longevity of your air conditioner.

5.1 Cleaning the Water Tank

The bottom water tank is removable for easy cleaning.

  1. Unplug the unit from the power outlet.
  2. Carefully pull out the bottom water tank.
  3. Empty any remaining water.
  4. Clean the tank with a mild detergent and water. Rinse thoroughly.
  5. Allow the tank to air dry completely before reinserting.
Image showing a child playing near the air cooler, highlighting its safe bladeless design, anti-pinch grid, and fully closable air vents.

Figure 5.1: Detachable and Washable Components (Bladeless Design)

5.2 General Cleaning

  • Wipe the exterior of the unit with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Ensure no water enters the internal electrical components.

5.3 Storage

  • Before storing, ensure the water tank is empty and clean.
  • Store the unit in a cool, dry place, away from direct sunlight and extreme temperatures.

6. Troubleshooting

If you encounter issues with your OEARE Portable Air Conditioner, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Unit does not turn onNo power supply; Power cord not properly plugged inCheck power outlet; Ensure power cord is securely plugged in
No cool air / Air is not cold enoughWater tank empty; Ice packs not frozen or used; Cooling mode not activated; Room temperature too high for evaporative cooling effectivenessFill water tank; Ensure ice packs are frozen and placed in tank; Select Cooling Mode; Evaporative coolers are most effective in dry climates. For very humid conditions, cooling effect may be limited.
Weak airflowAir inlets/outlets blocked; Fan speed set too lowClear any obstructions; Increase fan speed setting
Unusual noiseUnit not on a flat surface; Internal component issuePlace unit on a stable, flat surface; If noise persists, contact customer support
Remote control not workingBatteries depleted; Obstruction between remote and unitReplace remote control batteries; Ensure clear line of sight to the unit's receiver

If the problem persists after attempting these solutions, please contact customer support.

7. Specifications

Detailed technical specifications for the OEARE Portable Air Conditioner.

FeatureSpecification
BrandOEARE
Model NumberB0GSYQJ8L3
Mounting TypeFreestanding
ColorOff White
Controls TypeRemote, On-unit Panel
Recommended UsePersonal cooling for small rooms or offices
Form FactorPersonal
Number of Speeds3 (Low, Medium, High)
Operation Modes4 (Normal, Natural, Sleep, Cooling)
Water Tank Capacity6 Liters (6000ML)
Timer12-Hour
Noise LevelApproximately 35dB
OscillationAutomatic, 120-degree up and down adjust
Power Cord Length5 ft
Dimensions (Approx.)59.5 cm (Height) x 25 cm (Width) x 21 cm (Depth)
Diagram showing the dimensions of the portable air conditioner: 59.5cm height, 25cm width, 21cm depth.

Figure 7.1: Product Dimensions

© 2026 OEARE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.