1. Product Overview
The Wattive 4KW Variable Frequency Drive (VFD) Inverter is designed for converting 220V single-phase AC input to 380V three-phase AC output, providing precise speed control for various industrial applications. This device features advanced control algorithms and robust protection mechanisms to ensure reliable and efficient operation.
- High-Precision Vector Control: Utilizes an advanced VF/vector control algorithm for superior load capacity, powerful control, strong torque, and dynamic performance across a wide speed range. The corrosion-resistant PCB coating ensures stable operation in challenging environments (high temperature, humidity, dust).
- Comprehensive Protection: Integrated protection functions guard against overcurrent, overvoltage, undervoltage, overload, and phase loss. It also supports fault logging to reduce maintenance costs and ensure stable operation.
- User-Friendly Interface: Equipped with a high-resolution LED LCD display for clear monitoring of motor operating status. Supports an external keyboard with a 2-meter extension cable for enhanced convenience and flexibility.
- Efficient Heat Dissipation: Features a silent, high-speed fan and a separate air duct for powerful heat dissipation, ensuring long-term stable operation. The housing is made from flame-retardant ABS plastic, offering high impact resistance, high-temperature resistance, and excellent flame-retardant properties for improved safety.
- Wide Range of Applications: Ideal for motor drive equipment such as fans, water pumps, CNC machine tools, ball mills, injection molding machines, crushers, conveyor belts, and compressors.

2. Safety Information
Please read and understand all safety instructions before installing, operating, or maintaining the VFD inverter. Failure to follow these instructions may result in electric shock, injury, or equipment damage.
- Risk of Electric Shock: This device operates with high voltages. Always disconnect power before performing any installation, wiring, or maintenance.
- Capacitor Discharge: Wait at least 10 minutes after disconnecting power for DC bus capacitors to discharge before touching any internal components.
- Proper Grounding: Ensure the inverter is properly grounded according to local electrical codes and standards. Improper grounding can lead to electric shock.
- Output Terminals: Do not connect power to the output terminals (U, V, W). These terminals are for motor connection only.
- Qualified Personnel: Installation and maintenance should only be performed by qualified electrical personnel.
- Environmental Conditions: Operate the inverter within specified environmental conditions to prevent damage and ensure safety.

3. Specifications
Technical specifications for the Wattive 4KW VFD Inverter:
| Parameter | Value |
|---|---|
| Brand | Wattive |
| Model Number | UHEHBCEAH-3B41A594 |
| Rated Power | 4000 Watt (4KW) |
| Rated Input Voltage | Single-Phase 220V (AC) |
| Rated Output Voltage | Three-Phase 380V (AC) |
| Rated Frequency | 50/60 Hz |
| Output Frequency Range | 0-320Hz |
| Output Current | 8.5A |
| Product Dimensions (L x W x H) | 24L x 24W x 17.8H cm |
| Material | ABS Flame Retardant Plastic |
| Cooling Method | Heat Dissipation Fan |
| Recommended Uses | CNC machine tools, fans, pumps, injection molding machines, crushers, conveyor belts, compressors |

4. Setup and Installation
4.1 Wiring Instructions
Proper wiring is critical for the safe and correct operation of the VFD inverter. Refer to the wiring diagrams below and ensure all connections are secure and comply with local electrical regulations.
- Input Power (Single-Phase 220V): Connect the single-phase 220V AC power supply to the designated input terminals.
- Motor Connection (Three-Phase 380V): Connect your three-phase 380V motor to the output terminals (U, V, W).
- Grounding: Always connect the earth wire to the designated grounding terminal.
- Braking Resistor: The machine has a built-in braking resistor. An external braking resistor can be connected at the P+/PB position if required for specific applications.


4.2 Control Panel Installation
The control panel of the VFD inverter can be easily removed and installed remotely using the provided 2-meter extension cable. This offers flexibility in mounting the display for convenient access and monitoring.
- To remove the panel, gently unclip it from the main unit.
- Connect the extension cable to the panel and the main unit.
- Mount the panel in a desired location using appropriate fasteners (not included).

5. Operating Instructions
The VFD inverter features an intuitive control panel for easy operation and parameter adjustment.
5.1 Control Panel Overview

- LED Display: Shows current operating frequency, input voltage, and other parameters.
- PRG (Program) Key: Enters/exits parameter setting mode.
- FUNC (Function) Key: Used for various function selections.
- Shift Key (>>): Shifts cursor position during parameter editing.
- Up/Down Keys (▲/▼): Adjusts parameter values or navigates menus.
- Enter Key: Confirms selections or parameter changes.
- RUN Key: Starts motor operation.
- STOP Key: Stops motor operation.
5.2 Basic Parameter Settings
The VFD allows for adjustment of various parameters to suit specific motor and application requirements. Key parameter groups include:
- F00: Basic Operating Parameters: Includes fundamental settings like maximum frequency, acceleration/deceleration times.
- F01: Start/Stop Control Parameters: Settings related to motor start and stop behavior.
- F02: Motor Parameters: Specific motor data such as rated voltage, current, and frequency.
- F03: Reserved Parameters: Additional or advanced settings.
To adjust speed, simply use the rotary dial or the Up/Down keys on the control panel. The LED display provides real-time feedback on the motor's operating status.

6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your Wattive VFD Inverter.
- Cleaning: Periodically clean the exterior of the inverter to prevent dust accumulation, especially around the cooling fan and ventilation openings. Use a soft, dry cloth. Do not use liquid cleaners.
- Cooling System: Ensure the cooling fan is free from obstructions and operating correctly. The independent air duct design helps maintain efficient heat dissipation.
- Connections: Regularly check all electrical connections for tightness and signs of corrosion. Loose connections can lead to overheating or malfunction.
- Environmental Check: Ensure the operating environment remains within specified temperature and humidity ranges. The corrosion-resistant PCB coating provides protection in harsh conditions, but extreme environments should be avoided.
- Inspection: Visually inspect the inverter for any signs of damage, discoloration, or unusual odors.


7. Troubleshooting
The VFD inverter is equipped with comprehensive protection functions that can help diagnose and prevent issues. If you encounter problems, refer to the following general troubleshooting steps:
- Error Codes: The LED display will show specific error codes if a fault occurs (e.g., overcurrent, overvoltage, undervoltage, overload, phase loss). Consult the full product manual for a complete list of error codes and their remedies.
- Power Supply: Verify that the input power supply is stable and within the specified voltage range (220V AC).
- Motor Connection: Check that the motor is correctly wired to the output terminals (U, V, W) and that there are no loose connections.
- Overload: If an overload error occurs, check the motor's load and ensure it does not exceed the inverter's capacity. Reduce the load or adjust motor parameters if necessary.
- Overheating: Ensure adequate ventilation around the inverter and that the cooling fan is operating. Clear any obstructions to airflow.
- Grounding: Confirm that the inverter is properly grounded.
- Fault Logging: The inverter supports fault logging, which can provide historical data on issues. This information can be useful for diagnosing intermittent problems.
If the problem persists after performing these checks, contact customer support for further assistance.
8. Applications
The Wattive 4KW VFD Inverter is versatile and suitable for a wide range of industrial motor drive applications, including but not limited to:
- CNC Machine Tools
- Fans and Ventilation Systems
- Water Pumps
- Injection Molding Machines
- Crushers and Grinders
- Conveyor Belts
- Air Compressors
- Ball Mills

9. Warranty and Support
Wattive products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please refer to the contact details provided with your purchase or visit the official Wattive website. Please have your model number (UHEHBCEAH-3B41A594) and purchase date ready when contacting support.