Introduction
This manual provides instructions for the safe and effective use of the URIT Hb Test Meter (Model PH-01A). This device is designed for convenient and rapid measurement of hemoglobin levels. Please read this manual thoroughly before using the device.

Image: URIT Hb Test Meter PH-01A, showing the device with a digital display.
Package Contents
Verify that all items listed below are present in your package:
- 1 x URIT Hb Test Meter (Model PH-01A)
- 25 x Hemoglobin Test Strips
- 25 x Lancets
- 1 x Lancing Device
- 1 x Storage Bag
- 1 x User Manual (this document)

Image: Visual representation of the URIT Hb Test Meter kit contents, including the meter, lancing device, test strips, lancets, and storage bag.
Product Overview
Familiarize yourself with the components of the URIT Hb Test Meter:

Image: Diagram illustrating the various parts of the PH-01A meter, including Test Strip Inlet, Test Hole, Test Strip Slot, Test Strip Bracket, Code Card Slot, LCD, M Button, On/Off Button, and S Button.
- Test Strip Inlet: Where the test strip is inserted.
- Test Hole: Area for blood sample application.
- Test Strip Slot: Guides the test strip into position.
- Test Strip Bracket: Secures the test strip.
- Code Card Slot: For inserting the code card (if applicable for new strip batches).
- LCD: Liquid Crystal Display for showing results and messages.
- M Button: Memory button to review stored results.
- On/Off Button: Powers the device on or off.
- S Button: Setting button for time/date or other configurations.
Setup
Before first use, ensure the meter is ready for operation.
- Battery Installation: Open the battery compartment on the back of the meter and insert the alkaline batteries, ensuring correct polarity.
- Initial Power On: Press and hold the On/Off button to power on the meter.
- Date and Time Setting: If prompted, use the M and S buttons to set the correct date and time. Refer to the full manual for detailed instructions on setting these parameters.
- Code Card Insertion: For each new batch of test strips, insert the corresponding code card into the Code Card Slot. The meter will display the code. Remove the code card after the code is read. (Note: The same bottle of test strips does not require repeated settings.)
Operating Instructions
Quickstart Guide for Hemoglobin Testing

Image: Step-by-step visual quickstart guide for using the URIT Hb Test Meter, showing power on, code card insertion, strip insertion, blood collection, sample application, and result reading.
- Power On: Press and hold the On/Off button to turn on the meter.
- Insert Code Card (if needed): Insert the code card from the test strip vial, read the code, and then pull out the code card. (This step is not needed for subsequent tests from the same vial).
- Insert Test Strip: Turn on the hemoglobin meter and insert a test strip into the Test Strip Inlet.
- Prepare Lancing Device: Draw a blood sample using the lancing device and lancet included in the package. (Refer to "Blood Collection Steps" below for detailed instructions).
- Apply Blood Sample: When the flashing blood drop symbol appears on the screen, press the top of the test strip and place the blood sample close to the sample entry port of the test strip. The sample will automatically be drawn into the port.
- Read Results: Read the test results within 20 seconds on the LCD screen.
Blood Collection Steps

Image: Visual guide for blood collection, showing hand washing, lancing device assembly, and depth adjustment.
- Wash Hands: Wash your hands thoroughly with soap and water, then dry them completely.
- Prepare Lancing Device: Pull off the pen cap of the lancing device and insert a new lancet into the fixed frame.
- Secure Lancet: Screw down the blood collection needle cap onto the lancing device.
- Adjust Lancing Depth: Put on the blood collection pen cover and adjust the appropriate gear for different lancing depths (1-5, with 1 being shallow and 5 being deep) to suit your skin type.
- Obtain Blood Sample: Press the lancing device firmly against the side of your fingertip and press the release button to prick your finger. Gently squeeze your finger to form a round drop of blood.
Important Considerations for Accurate Results

Image: Infographic detailing key points for accurate hemoglobin test results, including pre-use checks and during-use precautions.
Before Use:
- Ensure the test strips are not contaminated, damp, or expired.
- Clean and dry your hands to ensure the blood won't be contaminated.
During Use:
- Massage your finger for 10 seconds and lower your arm for 5 seconds before blood sample collection.
- Ensure the blood sample is sufficient each time (10uL micro-sample).
- Avoid touching the contact bar and absorbent hole of the test strip.
Note:
Consecutive tests are unnecessary as each drop of blood differs, which may cause test results to vary.
Troubleshooting
Why are the results of two consecutive measurements different?

Image: Table outlining factors that affect accuracy and their corresponding solutions for hemoglobin testing.
| Factors that affect accuracy | Solutions |
|---|---|
| Alcohol, dirt, or other substances on your skin | Wash (or use an alcohol pad); please dry your hands and the testing site thoroughly before pricking your skin. |
| Not enough blood was applied to the test strip | Make sure you have enough amount of blood (10uL) for a test. |
| Wipe off tissue contains in your blood | Wipe off the first drop of blood, and then collect a drop of blood on the test strip, making sure you have an adequate amount (10uL) for a reading. |
| Test strip problems | Store strips in their sealed container; keep them away from heat, moisture, and humidity. |
| Testing site location | If you think the value is incorrect in the first test, please change your finger for the second test. |
| The interval between 2 same blood tests | If the 2 consecutive tests using the same blood are done within 5-10 seconds, there is a slightly different in readings (within 15%). If 2 readings are very different, please check the operation or the above factors, and then test again. |
Maintenance
Proper maintenance ensures the longevity and accuracy of your URIT Hb Test Meter.
- Cleaning: Wipe the meter's exterior with a soft, damp cloth. Do not immerse the meter in water or use harsh cleaning agents.
- Storage: Store the meter and test strips in the provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
- Battery Replacement: Replace batteries when the low battery indicator appears on the display.
- Test Strip Handling: Always keep test strips in their original sealed container and use them before their expiration date. Close the vial immediately after removing a strip.
Specifications
| Feature | Detail |
|---|---|
| Model | PH-01A |
| Manufacturer | URIT |
| Test Time | Approximately 20 seconds |
| Sample Volume | 10uL micro-sample |
| Memory Capacity | Up to 1,000 test results with time and date records |
| Included Components | 1 Meter, 25 Test Strips, 25 Lancets, 1 Storage Bag, 1 Lancing Device |
| Battery Type | Alkaline |
| Special Features | Easy to Use |
| Package Dimensions | 1.97 x 1.57 x 1.18 inches; 12.35 ounces |
Official Product Video
Video: Official demonstration of the URIT Hemoglobin Test Kit, showing the testing process from preparation to result reading. Duration: 2 minutes, 4 seconds.
Warranty and Support
Specific warranty information for the URIT Hb Test Meter is not provided in the product details. For warranty claims or technical support, please refer to the contact information provided with your product packaging or visit the official URIT website.