VEVOR SGPC-2500W

Rate this product if you’ve used it
Download PDF
Contents

VEVOR 2500W Sump Pump Battery Backup System

Model: SGPC-2500W

Introduction

This manual provides essential information for the safe and efficient operation of your VEVOR 2500W Sump Pump Battery Backup System. This pure sine wave inverter is designed to provide reliable backup power to your sump pump during power outages, ensuring continuous basement protection. It also features a 3-stage smart charging system to maintain optimal battery health.

Please read this manual thoroughly before installation and use, and retain it for future reference.

Safety Instructions

  • Electrical Safety: Always disconnect the system from AC power and batteries before performing any maintenance or installation. Ensure proper grounding.
  • Battery Handling: Use only compatible 12V batteries (Lead-acid, AGM, Gel, LiFePO4). Connect batteries with correct polarity (positive to positive, negative to negative). Avoid short-circuiting battery terminals.
  • Ventilation: Install the inverter in a well-ventilated area to prevent overheating. Do not block ventilation openings.
  • Environment: Keep the inverter away from water, moisture, flammable materials, and direct sunlight. Operate within specified temperature and humidity ranges.
  • Professional Installation: If you are unsure about any installation steps, consult a qualified electrician.
  • Overload Protection: Do not exceed the rated output power of 2500W. The system includes built-in protection against overcurrent, overvoltage, short circuit, reverse polarity, and high temperature.

Package Contents

Verify that all items are present in the package:

  • 1 x VEVOR 2500W Sump Pump Battery Backup System
  • 1 x Power Cord
  • 2 x Battery Connection Cables (Red for Positive, Black for Negative)
  • 8 x 50A Fuses
  • 1 x Instruction Manual

Product Overview and Features

The VEVOR 2500W Sump Pump Battery Backup System is designed for reliable power conversion and battery management. Key features include:

  • Pure Sine Wave Output: Delivers stable 2500W pure sine wave AC power, suitable for sensitive electronics and motors.
  • Dual-Pump Operation Support: Capable of supporting a 1 HP main pump and a 1/3 HP backup pump simultaneously.
  • Quick Plug-In Setup: Features a standard 3-prong plug for easy and secure installation, minimizing wiring complexity.
  • 3-Stage Smart Charging: Optimizes battery performance and extends service life with Bulk, Absorption, and Float charging stages. Compatible with 12V Lead-acid, AGM, Gel, and LiFePO4 batteries.
  • Real-Time LCD Display: Provides clear monitoring of voltage, battery level, working status, and other critical parameters.
  • Comprehensive Safety Protections: Built-in safeguards against overcurrent, overvoltage, short circuit, reverse polarity, and high temperature, with an additional circuit breaker for enhanced safety.
  • Additional Outputs: Includes a USB port and AC outlet for versatile emergency power needs.
VEVOR 2500W Sump Pump Battery Backup System connected to two sump pumps and a battery.

Figure 1: VEVOR 2500W Sump Pump Battery Backup System connected to two sump pumps and an external battery.

Front panel of the VEVOR 2500W Sump Pump Battery Backup System showing AC output sockets, USB port, and grid input.

Figure 2: Front panel of the VEVOR 2500W Sump Pump Battery Backup System, highlighting AC output sockets, USB port, and grid input.

Setup

Follow these steps for proper installation:

  1. Choose a Location: Select a dry, well-ventilated area for the inverter, away from direct sunlight, heat sources, and flammable materials. Ensure adequate space around the unit for airflow.
  2. Battery Connection: Connect the provided battery cables to your 12V battery bank. Ensure correct polarity: red cable to the positive (+) terminal and black cable to the negative (-) terminal. Secure connections tightly. The system is compatible with Lead-acid, AGM, Gel, and LiFePO4 batteries.
  3. AC Grid Input: Plug the inverter's power cord into a standard 120V AC wall outlet. This connection provides power to the inverter and initiates the battery charging process.
  4. Sump Pump(s) Connection: Plug your sump pump(s) into the AC output sockets on the front panel of the inverter. The system supports dual-pump operation (e.g., 1 HP main + 1/3 HP backup).
  5. Initial Power On: Once all connections are secure, turn on the inverter using the main power switch. The LCD display will illuminate, showing current status.
Comparison showing VEVOR's simple plug-and-play AC input versus complex wiring of other systems.

Figure 3: The VEVOR system features a simple plug-and-play AC input, simplifying installation compared to complex wired systems.

Operating Instructions

The VEVOR Sump Pump Battery Backup System operates automatically to ensure continuous protection.

  • Normal Operation (AC Power Present): When connected to AC grid power, the inverter will pass through AC power to your connected sump pump(s) and simultaneously charge the connected batteries using its 3-stage smart charging system. The LCD display will show input voltage, output voltage, and charging status.
  • Power Outage (Automatic Switchover): In the event of a power outage, the inverter will automatically and seamlessly switch to battery power within milliseconds (typically ≤15ms). It will convert the DC power from your batteries into 120V AC pure sine wave power to keep your sump pump(s) running. The LCD display will indicate battery voltage and output wattage.
  • Power Restoration: When AC grid power is restored, the inverter will automatically switch back to grid power and resume charging the batteries.
  • LCD Display Monitoring: Regularly check the LCD display for real-time information on input/output voltage, battery charge level, current wattage, and any error codes.
Detailed view of the VEVOR Sump Pump Inverter's LCD display showing real-time operational data and protection icons.

Figure 4: The LCD display provides real-time information such as input voltage, working temperature, AC output voltage, low voltage protection, loads power, over voltage protection, battery level, over temperature protection, frequency, and overload protection.

Video 1: This video provides an overview of the VEVOR 2500W Sump Pump Battery Backup System, demonstrating its features, setup, and how it functions during a power outage to keep your sump pump operational.

Maintenance

Regular maintenance ensures the longevity and reliability of your system:

  • Battery Inspection: Periodically check battery terminals for corrosion and ensure connections are tight. Clean any corrosion with a wire brush and baking soda solution.
  • Battery Health: Monitor battery voltage and charge status via the LCD display. Ensure batteries are fully charged during normal operation. Replace old or damaged batteries as needed.
  • Fuse Replacement: If the system experiences an overload or short circuit, a fuse may blow. Disconnect all power, locate the fuse holder, and replace the blown fuse with one of the same rating (50A).
  • Cleaning: Keep the inverter unit clean and free of dust and debris. Use a dry cloth to wipe the exterior. Ensure ventilation openings are clear.
  • Cable Integrity: Inspect all power and battery cables for any signs of wear, damage, or fraying. Replace damaged cables immediately.

Troubleshooting

If you encounter issues, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No power output / Inverter not turning onLoose connections, discharged battery, blown fuse, main power switch off.Check all cable connections. Ensure batteries are charged. Check and replace fuses if necessary. Turn on the main power switch.
Battery not chargingAC grid input not connected, AC power outage, faulty battery, charging circuit issue.Verify AC grid connection. Check for power outages. Inspect battery health. Contact support if issue persists.
Overload warning on LCDConnected load exceeds 2500W capacity.Reduce the total wattage of connected appliances. Ensure sump pump(s) do not exceed system capacity.
High temperature warningPoor ventilation, blocked fan, excessive ambient temperature.Ensure adequate airflow around the inverter. Clear any obstructions from fans. Move to a cooler environment if possible.

For issues not listed here, please contact VEVOR customer support.

Specifications

FeatureSpecification
BrandVEVOR
Model Name2500W Sump Pump Battery Backup System
Model NumberSGPC-2500W
Output Power2500 Watts
Inverter Peak Output Power5000W
Output Voltage120 Volts (AC)
Electrical Output WaveformPure Sine Wave
Frequency60 Hz
Battery System Voltage12VDC
Max Charging Current25A
Max Charging Voltage14.6V
Float Charging Voltage13.6V
AC Input Voltage85V-135VAC 60Hz
Item Weight13.89 Pounds (6.3 kg)
Product Dimensions (L x W x H)17.52 x 9.45 x 3.58 inches (445 x 240 x 91 mm)
Dimensions of the VEVOR 2500W Sump Pump Inverter and a list of included accessories.

Figure 5: Product dimensions and a summary of key specifications and accessories.

Warranty

For detailed warranty information, please refer to the warranty card included with your product or visit the official VEVOR website. Keep your purchase receipt as proof of purchase for any warranty claims.

Support

If you have any questions, require technical assistance, or need to report an issue, please contact VEVOR customer support through the following channels:

  • Online Support: Visit the VEVOR Support Center at www.vevor.com/support
  • Manufacturer Website: For more product information, visit the official VEVOR website.

© 2023 VEVOR. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.