Proster MR505

Proster Dual-Sensor Portable Breathalyzer MR505 User Manual

Model: MR505

Introduction

Thank you for choosing the Proster Dual-Sensor Portable Breathalyzer MR505. This device is designed to provide a quick and reliable indication of your Blood Alcohol Content (BAC) for personal use. It features dual high-precision sensors, voice prompts, and a clear 3-color LED display for easy interpretation of results. Please read this manual thoroughly before use to ensure proper operation and accurate readings.

Important Note: This device is intended for personal reference only and should not be used to determine whether you are fit to drive or operate machinery. Legal limits for BAC vary by region, and official calibration is required for legal purposes. Always prioritize safety and responsible decision-making.

Product Overview

Key Features

Device Components

Proster Breathalyzer components labeled: Air intake, LCD Screen, Menu button/power on button, Sound outlet, Vent hole, Charging Type-C port.
Figure 1: Proster Breathalyzer with labeled components including air intake, LCD screen, buttons, sound outlet, vent hole, and USB-C charging port.

Setup

1. Charging the Device

Before first use, or if the battery is low, charge the breathalyzer using the provided USB-C cable. Connect the cable to the Type-C port on the device and a compatible USB power source (e.g., wall adapter, computer USB port).

Proster Breathalyzer connected to a USB-C charging cable in a car's center console.
Figure 2: The breathalyzer charging via its USB-C port.

2. Installing a Mouthpiece

Insert one of the provided mouthpieces firmly into the air intake port at the top of the device. Ensure it is securely attached to prevent air leakage during testing.

Proster Breathalyzer with a mouthpiece inserted, held in a hand.
Figure 3: A mouthpiece being installed onto the breathalyzer.

3. Initial Sensor Cleaning (First Use / Long Storage)

For the first use, or if the device has been stored for an extended period, it is recommended to clean the sensor. Press the power button three times quickly to initiate a sensor cleaning cycle. This helps ensure optimal accuracy.

Operating Instructions

For accurate results, wait at least 20-30 minutes after eating, drinking (including non-alcoholic beverages), or smoking before performing a test. Residual alcohol in the mouth can lead to falsely high readings.

  1. Power On: Press and hold the power button (usually the central button) for a few seconds until the device powers on and the display illuminates.
  2. Preheating: The device will enter a preheating phase, indicated by a countdown on the screen (e.g., "Wait"). This typically takes about 10 seconds.
  3. Ready to Blow: Once preheating is complete, the device will display "Blow" and emit a voice prompt.
  4. Provide Breath Sample: Take a deep breath and blow steadily and continuously into the mouthpiece for approximately 5 seconds, or until you hear a beep and the display indicates completion. Ensure a consistent airflow.
  5. View Results: The device will process the sample and display your BAC reading on the LCD screen within approximately 4 seconds. Voice prompts will announce the result, and the 3-color LED indicator will light up according to the detected alcohol level.
  6. Switching Units: To cycle through different measurement units (%BAC, mg/L, g/L), double-click the power button after a test result is displayed.
  7. Power Off: The device will automatically power off after 10 seconds of inactivity following a test to conserve battery. You can also manually power it off by pressing and holding the power button.
Video 1: Demonstration of the Proster Breathalyzer's operation, including power-on, preheating, breath sample collection, and result display. This video illustrates the steps for using the device to obtain a BAC reading.

Understanding Results

The Proster Breathalyzer provides results using a 3-color LED indicator and numerical display. The device supports multiple units of measurement.

3-Color LED Indicator

Proster Breathalyzer showing green, yellow, and red indicators for different BAC levels.
Figure 4: The 3-color LED indicator system for interpreting BAC results.

Note: These thresholds are general guidelines. Always refer to local laws and regulations regarding alcohol limits.

Measurement Units

The device can display results in the following units:

Double-click the power button to switch between these display units.

Maintenance

Cleaning the Device

Storage

Store the breathalyzer in a cool, dry place away from direct sunlight and extreme temperatures. If storing for a long period, ensure the device is fully charged and perform a sensor cleaning cycle before next use.

Troubleshooting

ProblemPossible CauseSolution
Inaccurate or inconsistent readings
  • Tested too soon after eating, drinking, or smoking.
  • Improper blowing technique (not continuous or strong enough).
  • Sensor requires cleaning.
  • Wait at least 20-30 minutes before retesting.
  • Ensure a steady, continuous blow for the required duration.
  • Perform a sensor cleaning cycle (press power button 3 times).
Device does not power on
  • Low battery.
  • Device malfunction.
  • Charge the device fully.
  • Contact customer support if charging does not resolve the issue.
Voice prompts are too loud / cannot be adjusted
  • The device does not feature volume control.
  • This is a design characteristic. Use in environments where the volume is not disruptive.

If you encounter issues not listed here, please refer to the support section for assistance.

Specifications

Warranty and Support

For warranty information or technical support, please contact Proster customer service. You can find more information and contact details by visiting the official Proster store on Amazon:

Visit the Proster Store

Please have your model number (MR505) and purchase details ready when contacting support.

Related Documents - MR505

Preview Proster Wire Tracker User Manual
User manual for the Proster Multi-purpose Communication Network Wire Tracker, detailing its functions, specifications, and usage for tracking and verifying network and electric power cables.
Preview Proster Clamp Meter TRMS 6000 Counts User Manual
This user manual provides detailed instructions and specifications for the Proster Clamp Meter TRMS 6000 Counts, covering its features, operation, safety guidelines, and troubleshooting.
Preview Proster RZMT-10 MD Digital Wood Moisture Meter User Manual and Specifications
User manual and specifications for the Proster RZMT-10 MD digital wood moisture meter, detailing its features, operation, care, and technical specifications for measuring wood humidity. Includes wood species calibration groups.
Preview Proster Turntable Stylus Force Scale Gauge Tester User Manual
User manual for the Proster Turntable Stylus Force Scale Gauge Tester (PST052-EN-1). Provides an overview, specifications, operation instructions, and calibration details for accurately measuring stylus force on turntables.
Preview Proster Wireless Presenter with Laser Pointer User Guide
User guide for the Proster Wireless Presenter with Laser Pointer, including setup, specifications, safety measures, and troubleshooting.
Preview Proster XL830L Digital Multimeter User's Manual
User's manual for the Proster XL830L Digital Multimeter, covering safety precautions, general description, electronic symbols, function panel, operations instructions, technical specifications, maintenance, accessories, caution, warranty, and contact information.