wassermann ECM Circulator Pump WHM 20-40 SU Instruction Manual
Model: WHM 20-40 SU
1. Introduction and Product Overview
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your wassermann ECM Circulator Pump WHM 20-40 SU. Please read this manual thoroughly before installation and keep it for future reference.
The wassermann ECM Circulator Pump WHM 20-40 SU is a high-efficiency hot water circulator pump designed for various applications. It features advanced ECM technology for optimal performance and energy savings.
Figure 1: wassermann ECM Circulator Pump WHM 20-40 SU. This image highlights key performance metrics such as a maximum water flow of 11 GPM, a maximum head lift of 12.46 FT, a maximum operating pressure of 145 PSI, and a liquid temperature range of -50°F to +230°F.
2. Safety Information
Always observe the following safety precautions to reduce the risk of injury, electric shock, or property damage.
Electrical Safety: Ensure the pump is connected to a properly grounded electrical outlet. All electrical work should be performed by a qualified electrician in accordance with local codes.
Water Temperature: Be aware of the liquid temperature range. Do not exceed the maximum specified temperature to prevent damage to the pump and potential scalding.
Pressure: Do not exceed the maximum operating pressure. Install pressure relief valves if necessary.
Installation: Installation should only be performed by qualified personnel. Ensure all connections are secure and leak-free.
Maintenance: Disconnect power before performing any maintenance or service on the pump.
3. Package Contents
Verify that all items listed below are included in your package. If any items are missing or damaged, please contact customer support.
Figure 2: Contents included in the product package.
ECM Circulator Pump x 1
1" to 3/4" Adapter x 2
1" to 1/2" Adapter x 2
Nut x 2
Rubber Washer x 2
Teflon Tape x 1
9.8FT Three-prong Plug Power Cord x 1
Instruction Manual x 1
4. Setup and Installation
This section outlines the typical installation process for the wassermann ECM Circulator Pump in an open-loop hot water recirculation system. Consult a qualified plumber or HVAC technician for professional installation.
4.1 System Diagram
Figure 3: Typical installation for open loop hot water recirculation systems. This diagram illustrates the placement of the circulator pump, isolation valves, backflow preventer, thermal expansion tank, hot water tank, drain valves, and flow check valve within a plumbing system.
Follow the diagram above for proper placement of the pump and associated components. Ensure that isolation valves are installed on both sides of the pump to allow for easy servicing without draining the entire system. A backflow preventer and thermal expansion tank are recommended for system integrity.
4.2 Connecting the Power Cord
The pump comes with a pre-attached power cord. Locate the power cord connection point on the pump.
Figure 4: Power cord connection point. Simply insert the included power cord into this port until it is securely seated. The communication line connection point is not enabled for this model and should be ignored.
Insert the included 9.8FT three-prong plug power cord into the designated power connection port on the pump. Ensure a secure connection. The other port, labeled as a communication line connection, is not active for this model and should be disregarded.
5. Operating Instructions
The wassermann ECM Circulator Pump features a smart digital display for easy monitoring and control.
5.1 Control Panel Overview
Figure 5: Smart Circulating Pump control panel. This image details the running light, flow indicator light, power indicator light, digital display showing power, flow rate, and control mode, and the setting button.
Running Light: Indicates the operational status of the pump.
Flow Indicator Light: Shows if water is flowing through the pump.
Power Indicator Light: Displays the power status.
Digital Display: Shows current power consumption, flow rate, and the selected control mode.
Setting Button: Used to adjust pump settings and modes.
5.2 Indicator Meanings
Running Light
Cause
(No light)
The power is off. The pump is not running.
(Green light)
The power is on. The pump is running.
(Red light)
Alarm. The pump has stopped.
(Flashing green light)
The pump is externally controlled.
Digital Display
Meaning
CC
The pump is running in constant curve mode.
CP
The pump is running in constant pressure mode.
PP
The pump is running in proportional pressure mode.
50W
The power of current duty point is 50W (example value).
3.0m³/h
The flow rate of current duty point is 3.0 m³/h (example value).
Use the setting button to cycle through different operating modes (CC, CP, PP) and adjust parameters as needed for your specific application. Refer to the digital display for real-time feedback on power consumption and flow rate.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your wassermann ECM Circulator Pump. Always disconnect power before performing any maintenance.
Periodic Inspection: Periodically check for any leaks around the pump connections. Tighten connections if necessary.
Cleanliness: Keep the exterior of the pump clean and free from dust or debris.
System Flushing: If the pump is part of a heating or hot water system, follow the manufacturer's recommendations for system flushing to prevent sediment buildup.
Material Advantage: The pump head is constructed from stainless steel, which offers superior resistance to corrosion compared to cast iron pump heads. This contributes to cleaner water quality and a longer service life, reducing the need for frequent maintenance related to rust.
Figure 6: Comparison highlighting the benefits of a Stainless Steel Pump Head (clean water, durable service life) over a Cast Iron Pump Head (turbid water, easy to rust).
7. Troubleshooting
If you encounter issues with your pump, refer to the following troubleshooting guide. For problems not listed here, contact customer support.
Problem
Possible Cause
Solution
Pump not running (No running light)
No power supply.
Check power connection, circuit breaker, and ensure the outlet is functional.
Pump stopped (Red running light)
Alarm condition (e.g., overheating, blockage).
Disconnect power, allow pump to cool, check for obstructions in the system, then restart. If alarm persists, contact support.
No water flow
Air in the system, closed valves, or blockage.
Bleed air from the system, ensure all isolation valves are open, check for blockages.
Unusual noise or vibration
Air in the system, cavitation, or loose mounting.
Bleed air, ensure adequate water supply, check mounting bolts for tightness.
Pump externally controlled (Flashing green light)
External control signal active.
Verify external control system settings.
8. Specifications
Feature
Specification
Brand
wassermann
Model
WHM 20-40 SU
Product Weight
6 Pounds
Voltage
115 Volts
Power (Horsepower)
30 Watts
Unit Count
1.0 Count
Max Water Flow
11 GPM (Gallons Per Minute)
Max Head Lift
12.46 FT (Feet)
Max Operating Pressure
145 PSI (Pounds per Square Inch)
Liquid Temperature Range
-50°F to +230°F
9. Warranty and Support
For warranty information or technical support, please contact wassermann customer service. Keep your purchase receipt and product model number (WHM 20-40 SU) handy when contacting support.
Contact information can typically be found on the manufacturer's website or on the product packaging.
Related Documents - WHM 20-40 SU
Wassermann WP-Ex 3000 II Polishing Compact Unit User Manual User manual for the Wassermann WP-Ex 3000 II Polishing Compact Unit, detailing features, operation, maintenance, troubleshooting, and technical specifications for dental applications. Includes safety guidelines and EU declaration of conformity.
Wassermann DTC Economy Dental Cleaner User Manual User manual for the Wassermann DTC Economy dental cleaning unit. Provides detailed instructions on features, safety guidelines, operation, installation, maintenance, troubleshooting, and technical specifications for efficient dental tray and retention plate cleaning.
Wassermann Gipstrimmer HSS-88 / HSS-88 Super Betriebsanleitung Diese Betriebsanleitung bietet detaillierte Informationen zur Installation, Bedienung, Wartung und Sicherheit des Wassermann Gipstrimmers HSS-88 und HSS-88 Super für zahntechnische Labore.
Wassermann Wasi-Steam Classic Steam Cleaner User Manual Comprehensive user manual for the Wassermann Wasi-Steam Classic steam cleaner, detailing features, safety instructions, operation procedures, maintenance, troubleshooting, technical specifications, and EU compliance for dental applications.
Wassermann Sidomix III: Operating Manual for Dental Mixing and Dosing Device Comprehensive operating manual for the Wassermann Sidomix III, a 1:1 mixing and dosing device for dental applications. Covers features, safety instructions, installation, operation, troubleshooting, maintenance, technical specifications, and disposal.
Wassermann HSS-88 Plaster Model Trimmer User Manual This user manual provides detailed instructions for the Wassermann HSS-88 plaster model trimmer, covering installation, operation, safety guidelines, maintenance, troubleshooting, technical specifications, and disposal. Designed for dental laboratories.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.