Introduction
The Bosean T-Z01 Pro is a high-performance portable air quality monitor designed to accurately measure various air pollutants. This device provides real-time monitoring of PM2.5, HCHO (Formaldehyde), TVOC (Total Volatile Organic Compounds), CO (Carbon Monoxide), CO2 (Carbon Dioxide), and the overall AQI (Air Quality Index). It incorporates advanced sensors for reliable and stable performance.
Key features include:
- Live voice prompt and alarm function for immediate alerts.
- Built-in memory storing the last 8 hours of data, accessible via the history interface.
- Continuous battery monitoring with low power reminder.
- One-click voice on/off function for user convenience.
- Supports free switching between Chinese and English languages.
- Data evaluation function to assess air quality trends.

Figure 1: Bosean T-Z01 Pro Air Quality Monitor with dimensions and indication of HCHO, PM2.5, TVOC, temperature, and humidity sensors.
Package Contents
Please verify that all items are present in the package:
- 1 x Bosean T-Z01 Pro Air Quality Monitor
- 1 x User Manual
- 1 x USB Type-C Charging Cable
Device Overview

Figure 2: Technical parameters and labeled components of the Bosean T-Z01 Pro. Key components include the Vent, Display screen, Power switch, Type-C interface, Mute on/off button, Support frame, Setting/Select/Confirm button, and Return key.
- Vent: Air intake/output for sensor readings.
- Display Screen: Shows real-time air quality data and settings.
- Power Switch: Turns the device on or off.
- Type-C Interface: For charging the device.
- Mute On/Off: Toggles voice prompts and alarms.
- Support Frame: Allows the device to stand upright on a table.
- Setting/Select/Confirm Button: Used to navigate menus and confirm selections.
- Return Key: Used to go back in menus or cancel operations.
Setup
1. Charging the Device
Before first use, fully charge the Bosean T-Z01 Pro. Connect the provided USB Type-C cable to the Type-C interface on the device and the other end to a standard USB power adapter (not included) or a computer's USB port. The battery indicator on the display will show charging status. A full charge typically takes a few hours.

Figure 3: The Bosean T-Z01 Pro features a built-in 1500mAh battery and is USB rechargeable, allowing for 24-hour continuous monitoring.
2. Powering On/Off
To power on the device, press and hold the Power Switch button located on the side. The display will light up. To power off, press and hold the Power Switch button again until the display turns off.
3. Initial Placement
Place the monitor on a stable, flat surface using its integrated support frame. Ensure it is in an area representative of the air quality you wish to measure, away from direct airflow from vents, windows, or strong chemical sources that could skew readings.
Operating Instructions
1. Understanding the Display
The main display provides real-time readings for various parameters. Refer to the image below for a detailed breakdown of the display elements:

Figure 4: Operation notice showing the main display interface with Temperature, Humidity, HCHO, PM2.5, CO, CO2, TVOC concentrations, and AQI index. Also shown are the System Setup Interface and History Record Interface.
- Temperature: Current ambient temperature.
- Humidity: Current ambient relative humidity.
- HCHO Concentration: Formaldehyde levels in mg/m³.
- PM2.5 Concentration: Particulate matter 2.5 levels in µg/m³.
- CO Concentration: Carbon Monoxide levels in ppm.
- CO2 Concentration: Carbon Dioxide levels in ppm.
- TVOC Concentration: Total Volatile Organic Compounds levels in mg/m³.
- AQI Index: Air Quality Index, indicating overall air quality level (Good, Slight, Moderate, Serious).
- Battery Capacity: Icon indicating remaining battery life.
- Speech State: Icon indicating if voice prompts are active.
2. Navigating Menus and Settings
Use the '<' and '>' buttons to navigate through menu options. The 'SET' button is used to select an option or confirm a setting. The 'Return' key allows you to go back to the previous screen or exit a menu.
3. Language Switching
The device supports switching between Chinese and English. Access the System Setup Interface (as shown in Figure 4) to change the language setting. Navigate to 'Language' and select your preferred option.
4. Voice Prompt and Alarm Function
The device provides live voice prompts and an alarm function for critical air quality levels. To toggle the voice prompts on or off, use the dedicated Mute On/Off button (refer to Figure 2). Alarm thresholds can typically be adjusted within the System Setup Interface under 'Alarm point'.
5. Viewing History Data
The Bosean T-Z01 Pro stores the last 8 hours of air quality data. To view this data, navigate to the History Record Interface (as shown in Figure 4) through the device's menu. This interface displays a graph of historical readings, allowing you to monitor trends over time.
6. Data Evaluation Function
The device includes a data evaluation function to help interpret the measured air quality. Consult the manual's specific section on data evaluation or the device's on-screen prompts for understanding these assessments.
Maintenance
1. Cleaning
Wipe the device's exterior with a soft, dry cloth. Do not use abrasive cleaners, solvents, or immerse the device in water. Ensure the vents are clear of dust and debris to maintain accurate readings.
2. Storage
When not in use for extended periods, store the device in a cool, dry place, away from direct sunlight and extreme temperatures. It is recommended to charge the device periodically to maintain battery health.
3. Sensor Care
The sensors are delicate. Avoid exposing the device to high concentrations of pollutants for prolonged periods, as this can affect sensor lifespan and accuracy. Do not attempt to clean or tamper with the internal sensors.
Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not turn on. | Low battery or device is not charged. | Connect the device to a power source using the USB Type-C cable and charge it fully. Ensure the power button is pressed and held correctly. |
| Inaccurate or fluctuating readings. | Device placed near strong air currents, pollutants, or in a dusty environment. Sensors may need time to stabilize. | Move the device to a stable location away from direct airflow or pollutant sources. Allow 5-10 minutes for sensors to stabilize after powering on. Ensure vents are not blocked. |
| Voice prompts are not working. | Voice function is muted. | Press the Mute On/Off button to enable voice prompts. Check volume settings in the System Setup Interface if available. |
| Battery drains quickly. | Frequent use of voice prompts or high display brightness. Aging battery. | Reduce display brightness or disable voice prompts if not needed. Ensure the device is fully charged before use. If the issue persists, contact customer support. |
Specifications
| Model | T-Z01 Pro (IK-T-Z01) |
| Brand | Instrukart (Bosean) |
| Detected Gases | PM2.5, HCHO, TVOC, CO, CO2, AQI |
| Sensors | High-accuracy laser dust sensor, Electrochemical formaldehyde sensor, Semiconductor air quality sensor, Temperature-humidity sensor |
| Battery | Built-in 1500mAh |
| Charging Interface | USB Type-C |
| Item Weight | 500 g |
| Product Dimensions (LxWxH) | 12 x 9 x 14 cm |
| Memory | Stores last 8 hours of data |
| Language Support | Chinese, English |
Warranty and Support
Warranty Information
This product is covered by a standard manufacturer's warranty. Please refer to the warranty card included in your package or contact Instrukart Holdings for specific warranty terms and conditions. Keep your purchase receipt as proof of purchase for warranty claims.
Customer Support
For technical assistance, troubleshooting, or warranty inquiries, please contact Instrukart Holdings:
- Manufacturer/Packer: Instrukart Holdings
- Address: Plot 18, Street No: 1A, Czech Colony, Sanath Nagar, Hyderabad, Telangana 500018, India
- Contact Number: +918142350506
When contacting support, please have your product model number (T-Z01 Pro or IK-T-Z01) and purchase details ready.