Introduction
This manual provides essential information for the safe and efficient use of your Vidapool 2HP In/Above Ground Pool Pump with Timer, Model SPT200-HV. Please read all instructions carefully before installation and operation. Retain this manual for future reference.

Image: The Vidapool 2HP In/Above Ground Pool Pump, Dark Grey, featuring its main components.
Important Safety Information
- Always disconnect power before servicing the pump.
- Ensure proper grounding to prevent electrical shock.
- The pump is equipped with built-in automatic thermal overload protection to prevent motor overheating and burnout.
- The 6-foot power cord is UL tested for safety and performance.
- Do not operate the pump when the piping system is closed.
- Consult a qualified electrician for any wiring concerns.
Setup and Installation
The Vidapool pool pump is designed for straightforward installation. Follow these steps for proper setup:
1. Unpacking and Inspection
Carefully remove all components from the packaging. Inspect the pump and accessories for any signs of damage. Contact customer support immediately if any parts are damaged or missing.
2. Component Identification

Image: Labeled diagram of the pool pump components, including 1.5" ID Adapters, 2" ID Adapters, Filter Basket, Drain Plug, Pure Copper Motor, 5' Power Cord, Earthing Terminal, Timer, and Lid Opener.
- 1.5" ID Adapters: For connecting 1.5-inch piping.
- 2" ID Adapters: For connecting 2-inch piping.
- Filter Basket: Collects debris before it enters the pump.
- Drain Plug: For draining water from the pump housing.
- Pure Copper Motor: The pump's power unit.
- 5' Power Cord: Electrical connection.
- Earthing Terminal: For grounding the unit.
- Timer: Integrated control for scheduling operation.
- Lid Opener: Tool for opening the filter basket lid.
3. Electrical Connection
The pump operates on 220V power. Ensure your electrical supply matches this requirement. The pump features a 6-foot UL-tested cord. Connect the pump to a properly grounded outlet.

Image: A close-up view of the pump's power cord, highlighting its UL certification for safety.
4. Plumbing Connections
The pump includes two 1.25-inch and two 1.5-inch inlet and outlet adapters, compatible with 40 PVC pipe. Choose the appropriate adapters for your pool's plumbing system.

Image: Diagram illustrating two methods for connecting the pump's inlet and outlet pipes using PVC glue or PVC hose with clamps.
- Method 1: 1-1/2" or 2" Schedule 40 PVC Pipe Glue Connection.
- Method 2: 1-1/2" or 2" Schedule 40 PVC Pipe Glue Connection + 2" PVC Hose with Clamp.
Ensure all connections are secure and watertight to prevent leaks and maintain optimal pump performance.
5. Priming the Pump
Before starting the pump for the first time, or after draining, the pump must be primed. Fill the filter basket with water until the pump housing is full. Securely close the lid before starting the pump.
Operating Instructions
The Vidapool pump features an integrated timer for automated operation.
Setting the Timer
The pump offers nine run-time options, from 2 to 24 hours. Once set, the pump will activate automatically at the same time each day.

Image: Close-up of the pump's timer control panel, showing options for running hours (2, 4, 6, 8, 10, 12, 14, 16, 24) and an ON/OFF switch.
- Calculate Run Time: Determine the appropriate pump run time based on your pool size and usage.
- Set Start Time: Wait until the desired time you want the pump to begin its daily cycle.
- Select Running Hours: Press the clock button on the timer panel to choose the desired running hours (e.g., 2, 4, 6, 8, 10, 12, 14, 16, 24).
- Automatic Operation: The pump will now run for the set hours each day, starting at the time you initially set it.
The pump operates with exceptional stability, producing ultra-low noise during operation.
Maintenance
Regular maintenance ensures the longevity and efficient performance of your pool pump.
Filter Basket Cleaning
The large filter basket effectively collects debris such as leaves, hair, and coarse particles. Regular inspection and cleaning are crucial.

Image: The detachable filter basket, designed for easy removal and cleaning of collected debris.
- Power Off: Always turn off the pump and disconnect power before opening the filter basket.
- Remove Lid: Use the provided lid opener tool to carefully remove the filter basket lid.
- Empty Basket: Lift out the filter basket and empty any collected debris.
- Rinse: Rinse the basket thoroughly with water.
- Reinstall: Place the clean basket back into the pump housing, ensuring it is seated correctly. Securely fasten the lid.
Inspect the pump for any visible damage or wear during cleaning. Address any issues promptly.
Troubleshooting
This section provides solutions to common issues you might encounter with your pool pump.
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power supply; tripped circuit breaker; motor overload protection activated. | Check power connection and circuit breaker. Allow motor to cool if overload protection activated. |
| Low water flow | Clogged filter basket; air leak in suction line; low water level in pool. | Clean filter basket. Check and seal suction line for air leaks. Ensure adequate pool water level. |
| Pump is noisy | Air in system; cavitation; worn bearings. | Check for air leaks in suction line. Ensure proper water flow to prevent cavitation. If bearings are worn, contact support. |
| Water leak | Loose connections; damaged O-rings or seals. | Tighten all plumbing connections. Inspect and replace any damaged O-rings or seals. |
If you encounter issues not listed here or if solutions do not resolve the problem, please contact Vidapool customer support.
Specifications
Detailed technical specifications for the Vidapool 2HP In/Above Ground Pool Pump with Timer, Model SPT200-HV.

Image: Visual representation of key pump specifications and flow rate at different total heads.
| Feature | Detail |
|---|---|
| Brand | Vidapool |
| Model Number | SPT200-HV |
| Horsepower | 2 HP |
| Voltage | 220 Volts |
| Maximum Flow Rate | 8120 GPH (135 Gallons Per Minute) |
| Maximum Lifting Height | 60 Feet |
| Material | Cast Iron, Plastic |
| Power Source | AC |
| Inlet/Outlet Adapters | 1.25-inch and 1.5-inch (compatible with 40 PVC pipe) |
| Cord Length | 6 feet |

Image: Diagram illustrating the physical dimensions of the pump, including height (11.8"), length (24"), and inlet/outlet sizes (1.5" or 2").
Warranty and Support
Warranty Information
This Vidapool In/Above Ground Pool Pump is backed by a two-year warranty from the date of purchase. This warranty covers manufacturing defects and ensures customer peace of mind and satisfaction.
Please retain your proof of purchase for warranty claims.
Customer Support
For technical assistance, troubleshooting guidance, or warranty claims, please contact Vidapool customer service. Refer to your product packaging or the retailer's website for the most current contact information.
When contacting support, please have your model number (SPT200-HV) and purchase date available.
Product Overview Video
Video: An official product video from Langley Tools (Vidapool seller) providing an overview of the Vidapool Pool Pump with Timer, demonstrating its features and ease of use.