1. Introduction
This manual provides essential instructions for the safe and efficient operation, setup, and maintenance of your VEVOR 7 CFM 3/4 HP Two-Stage Rotary Vane AC Vacuum Pump. This pump is designed for various applications including HVAC maintenance, automotive air conditioning servicing, resin degassing, and wood stabilization. Please read this manual thoroughly before use and retain it for future reference.

Figure 1: VEVOR 7 CFM 3/4 HP Two-Stage Rotary Vane AC Vacuum Pump.
2. Safety Information
Always observe the following safety precautions to reduce the risk of injury or damage to the equipment:
- Electrical Safety: Ensure the power supply matches the pump's requirements. Do not operate with damaged cords or plugs. Avoid using in wet conditions.
- Personal Protective Equipment (PPE): Always wear safety glasses and gloves when operating the vacuum pump, especially when handling refrigerants or vacuum oil.
- Ventilation: Operate the pump in a well-ventilated area to prevent the accumulation of refrigerant vapors.
- Hot Surfaces: The pump motor and housing can become hot during operation. Avoid touching hot surfaces.
- Oil Handling: Use only recommended vacuum pump oil. Dispose of used oil responsibly according to local regulations.
- Refrigerant Handling: Be familiar with proper refrigerant handling procedures and safety guidelines. Never release refrigerants into the atmosphere.
- Stability: Place the pump on a stable, level surface to prevent tipping during operation.
- Children and Pets: Keep children and pets away from the operating area.
3. What's in the Box
Upon unpacking, verify that all items are present and undamaged:
- 1 x Vacuum Pump
- 1 x 0.26 qt./250 ml Oil Bottle
- 1 x User Manual

Figure 2: Included items with the VEVOR Vacuum Pump.
4. Specifications
| Feature | Detail |
|---|---|
| Item Model Number | 2RS-2 |
| Power | 3/4 HP, 550W |
| Free Air Displacement | 7 CFM / 198 L/min |
| Ultimate Vacuum | 0.3 Pa / 2.25 Microns |
| Air Inlet Port | 1/4" SAE, 1/2" ACME, 3/8" SAE |
| Compatible Refrigerants | R134a, R22, R410a, R1234YF, R32 |
| Net Weight | 20.94 lbs / 9.5 kg |
| Product Dimensions | 12.8 x 4.92 x 8.86 inches |

Figure 3: Detailed specifications and dimensions of the vacuum pump.
5. Setup
Follow these steps for initial setup of your VEVOR vacuum pump:
- Unpack and Inspect: Carefully remove the pump from its packaging. Inspect for any shipping damage.
- Positioning: Place the pump on a firm, level surface in a well-ventilated area. Ensure adequate space around the pump for air circulation.
- Fill with Oil:
- Remove the oil filler cap (often dual-purpose as an air outlet).
- Pour the provided vacuum pump oil into the oil reservoir until the oil level is between the "MIN" and "MAX" marks on the sight glass. The oil capacity is approximately 250 ml (0.26 qt).
- Replace the oil filler cap securely.

Figure 4: Filling the vacuum pump with oil and checking the oil level through the transparent window.
- Connect Power: Ensure the power switch is in the "OFF" position. Connect the power cord to a grounded electrical outlet that matches the pump's voltage requirements.
- Port Selection: Identify the appropriate inlet port (1/4" SAE, 1/2" ACME, or 3/8" SAE) for your application.

Figure 5: The multiple inlet ports for various HVAC systems.
6. Operating Instructions
This section outlines general operating procedures. Specific applications may require additional steps or specialized equipment.
6.1 General Vacuuming Procedure
- Connect Hoses: Connect the appropriate vacuum hose from your system (e.g., HVAC manifold gauge set, vacuum chamber) to one of the pump's inlet ports. Ensure all connections are tight to prevent leaks.
- Open Valves: Open any valves on your system that lead to the vacuum pump.
- Start Pump: Flip the power switch to the "ON" position. The pump will begin to operate.
- Monitor Vacuum: Observe the vacuum gauge on your system. Allow the pump to run until the desired vacuum level is achieved. For HVAC systems, this typically involves reaching a deep vacuum to remove moisture and non-condensable gases.
- Close Valves: Once the desired vacuum is reached, close the valves on your system first, then turn off the vacuum pump. This prevents oil from being drawn back into the system.
- Disconnect: Carefully disconnect the hoses from the pump and your system.
6.2 Applications
The VEVOR vacuum pump is suitable for a range of tasks:
- HVAC Maintenance: Evacuating air conditioning and refrigeration systems.
- Automotive A/C Servicing: Preparing automotive A/C systems for refrigerant charging.
- Resin Degassing: Removing air bubbles from epoxy resins and other casting materials.
- Wood Stabilization: Impregnating wood with stabilizing resins under vacuum.
- Laboratory Experiments: Various laboratory applications requiring a vacuum.

Figure 6: Versatile applications of the VEVOR Vacuum Pump.
Video 1: Demonstration of the VEVOR Vacuum Pump in operation for HVAC maintenance.
7. Maintenance
Regular maintenance ensures optimal performance and extends the lifespan of your vacuum pump.
- Check Oil Level: Before each use, check the oil level through the sight glass. The oil should be between the "MIN" and "MAX" marks. Add oil if necessary.
- Change Oil:
- Change the vacuum pump oil after every 10-20 hours of operation, or more frequently if the oil appears cloudy or discolored.
- Ensure the pump is cool and unplugged.
- Place a suitable container under the oil drain plug.
- Remove the oil drain plug and the oil filler cap to allow the oil to drain completely.
- Replace the drain plug and refill with new vacuum pump oil as described in the "Setup" section.

Figure 7: Checking the oil level using the transparent oil window.
- Clean Exterior: Wipe down the exterior of the pump with a damp cloth to remove dust and debris. Do not use harsh chemicals or solvents.
- Storage: When not in use, store the pump in a clean, dry environment.
8. Troubleshooting
Refer to the table below for common issues and their solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start | No power; Faulty switch; Motor issue | Check power connection and outlet; Inspect power cord; Contact support if motor is faulty. |
| Poor vacuum performance | Low oil level; Contaminated oil; Leaks in system/hoses; Clogged inlet filter | Check and add oil; Change oil; Check all connections for leaks; Clean or replace inlet filter. |
| Excessive noise/vibration | Low oil level; Loose components; Pump not on level surface | Check oil level; Tighten any loose parts; Ensure pump is on a stable, level surface. |
| Oil mist from exhaust | Overfilled oil; Contaminated oil; Normal during initial startup | Check oil level and drain excess if overfilled; Change oil; This may subside after a few minutes of operation. |
9. Warranty & Support
For warranty information or technical support, please refer to the warranty card included with your product or visit the official VEVOR website. Keep your purchase receipt as proof of purchase for any warranty claims.
Manufacturer: VEVOR
Model: 2RS-2
Date First Available: November 21, 2025