1. Safety Information
Please read and understand all safety instructions before operating the SZJMS NF-826 Underground Wire Locator. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Electrical Shock Hazard: Always ensure the circuit is de-energized before connecting the transmitter to any wires.
- Battery Safety: To avoid electrical shock, remove test leads before replacing the battery or opening the device case.
- Voltage Limits: Do not exceed the specified voltage limits (12V to 400V AC/DC) for testing.
- Proper Use: Use the device only for its intended purpose as an underground wire locator and cable tracer.
- Environmental Conditions: Avoid using the device in wet conditions or extreme temperatures.
2. Product Overview
The SZJMS NF-826 is a professional underground wire locator designed to detect and trace cables buried in walls or underground. It helps identify interruptions, short circuits, and locate covered outlets or distribution points. The device consists of an Emitter (Transmitter) and a Receiver unit.
Key Features:
- Multi-Functional: Detects cable conditions (interrupted, short-circuited), locates outlets, and tracks buried wires.
- Adjustable Sensitivity: Receiver sensitivity can be adjusted manually or automatically for various wiring scenarios.
- Dual Alerts: Utilizes sound and LCD screen for clear indication of signal strength and location.
- Rechargeable Batteries: Both transmitter and receiver feature detachable rechargeable batteries, providing approximately 8 hours of continuous use.
- Built-in Flashlight: High-intensity flashlight on both units for operation in dimly lit environments.
- Mute Function: Allows for silent operation in sensitive environments.
- AC/DC Voltage Detection: Measures voltages from 12V to 400V, displaying real-time values and providing audible alerts for live cables.
Components:

The NF-826 kit includes the transmitter, receiver, test leads, ground rod, USB charging cable, and user manual, all neatly organized in a durable carrying case.

A closer look at the included accessories: the ground rod for effective grounding, and the red and black test leads for connecting to circuits.
3. Setup
3.1 Charging the Devices
Both the Emitter and Receiver units are powered by rechargeable batteries. Before first use, ensure both units are fully charged using the provided USB charging cable.

The Emitter and Receiver units feature USB charging ports for convenient recharging.
3.2 Connecting Test Leads
Connect the red and black test leads to the corresponding ports on the Emitter unit. For tracing, connect the red lead to the wire you wish to trace and the black lead to a suitable ground point (e.g., the provided ground rod inserted into the earth, or a known ground connection).

Proper connection of the emitter to the cable and ground is crucial for accurate tracing of underground lines.
4. Operating Instructions
4.1 Basic Wire Tracing
- Connect the Emitter to the target wire and a ground point.
- Turn on both the Emitter and Receiver units.
- Adjust the Receiver's sensitivity using the up/down arrows to achieve a clear signal without excessive interference.
- Move the Receiver along the suspected path of the wire. The signal strength displayed on the LCD and the audible tone will increase as you approach the wire.
- The strongest signal indicates the wire's location.

The receiver can effectively detect pipes and wires embedded within walls, helping to identify disconnections or short circuits in electric heating lines under the floor.
4.2 Detecting Wire Breaks and Short Circuits
To locate a wire break or short circuit, connect the Emitter to one end of the wire. Use the Receiver to follow the signal along the wire's path. A sudden drop or loss of signal indicates a break. For short circuits, the signal may become erratic or disappear at the fault location.

The device is capable of detecting breaks and short circuits in buried cables, including those for dog fences or irrigation systems.
4.3 Locating Fuses and Sockets
Connect the Emitter to the circuit you wish to trace. Use the Receiver to scan the fuse box or wall outlets. The strongest signal will indicate the correct fuse or the location of a covered socket.

Easily find fuses, fuse circuits, and covered sockets or junction boxes with the NF-826.
4.4 Special Functions
- Mute Function: Press the mute button on either unit to silence audible alerts for use in quiet environments.
- Flashlight: Activate the built-in flashlight for improved visibility in dark areas.
- NCV (Non-Contact Voltage) Test: The Receiver has an NCV function to detect live AC voltage without direct contact.

The mute function allows for discreet operation, ensuring detection activities do not disturb others.

Both the transmitter and receiver are equipped with flashlights to illuminate work areas.
4.5 Instructional Video
This video demonstrates the functionality of the NF-826 Underground Wire Locator, showcasing its use in various detection scenarios.
5. Maintenance
5.1 Battery Care
The NF-826 units are equipped with 1400mAh rechargeable batteries. To ensure optimal battery life:
- Charge the devices fully before extended storage.
- Avoid completely draining the battery frequently.
- Recharge using the provided USB cable.
5.2 Cleaning and Storage
- Wipe the devices with a soft, dry cloth after each use. Do not use abrasive cleaners or solvents.
- Store the device and its accessories in the provided carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
- Ensure all test leads are disconnected before storing.
6. Troubleshooting
Common Issues and Solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| No signal or weak signal | Low battery; improper connection; excessive depth/interference; incorrect sensitivity setting. | Charge batteries; ensure secure connections to wire and ground; adjust receiver sensitivity; reduce interference from other electrical sources. |
| Inaccurate tracing | High sensitivity; multiple wires in close proximity; environmental interference. | Lower receiver sensitivity; try tracing from both ends of the wire; ensure proper grounding. |
| Device not powering on | Depleted battery; power button not pressed correctly. | Charge the device; press and hold the power button for a few seconds. |
| No audible alert | Mute function activated; low signal strength. | Deactivate mute function; increase sensitivity or ensure closer proximity to the wire. |
7. Specifications
| Feature | Detail |
|---|---|
| Brand | SZJMS |
| Model | NF-826 |
| Power Source | Battery Powered (Rechargeable) |
| Color | RED |
| Item Weight | 1.03 Kilograms |
| Minimum Operating Voltage | 12 Volts |
| Measurement Type | General Electrical Measurement |
| Specification Met | CE, ETL |
| Included Components | 1x NF-826 Transmitter, 1x Receiver, 1x Tool Bag |
8. Warranty & Support
Warranty Information:
Specific warranty details for the SZJMS NF-826 Underground Wire Locator are typically provided with your purchase documentation. Please refer to the warranty card or contact the seller/manufacturer directly for information regarding warranty periods, coverage, and claims.
Customer Support:
For technical assistance, troubleshooting beyond this manual, or inquiries regarding your product, please contact SZJMS customer support or your authorized retailer. Contact information can usually be found on the product packaging or the manufacturer's official website.