1. Introduction
This manual provides detailed instructions for the setup, operation, and maintenance of your Richmat HJH173 replacement remote control for adjustable bed bases. Please read this manual thoroughly before using the remote control to ensure proper function and to prevent damage.
The Richmat HJH173 remote is designed as a direct replacement for specific adjustable bed bases, including some Leggett & Platt and TempurPedic models that utilize the HJH173 remote. Verify that the buttons on your new remote match your original remote for compatibility.
2. Safety Information
- Keep the remote control away from water and excessive moisture.
- Do not expose the remote control to direct sunlight or extreme temperatures.
- Do not attempt to disassemble or repair the remote control yourself. Contact support if issues arise.
- Dispose of used batteries responsibly according to local regulations.
- Keep batteries out of reach of children.
3. Package Contents
Ensure all items are present in the package:
- Richmat HJH173 Replacement Remote Control (1 unit)
Note: Batteries are not included and must be purchased separately. This remote typically requires AAA batteries.
4. Setup
4.1 Battery Installation
- Locate the battery compartment cover on the back of the remote control.
- Slide the cover downwards or press the tab and lift to open the compartment.
- Insert two (2) AAA batteries, ensuring the positive (+) and negative (-) terminals align correctly with the markings inside the compartment.
- Replace the battery compartment cover by sliding it back into place until it clicks securely.

Figure 1: Battery compartment with batteries inserted.
4.2 Pairing Instructions
The remote control will not function out of the box and must be paired with your adjustable bed base. The pairing process may vary slightly depending on your bed base model. Refer to your bed base's original manual for specific instructions if these steps do not work. A common pairing procedure is as follows:
- Ensure the bed base is plugged into a working power outlet.
- Locate the "Learn" or "Pair" button on the control box of your adjustable bed base. This box is typically located under the bed frame.
- Press and hold the "Learn" or "Pair" button on the bed base control box for approximately 3-5 seconds until an indicator light (usually blue or green) on the control box begins to flash. This indicates the bed base is in pairing mode.
- Within 10 seconds of the light flashing, press and hold the "Head Up" button (or a designated pairing button if present) on your new Richmat HJH173 remote control.
- Hold the button on the remote until the indicator light on the bed base control box stops flashing and remains solid, or until the bed base makes a slight movement. This confirms successful pairing.
- Test the remote control by pressing various function buttons to ensure it operates the bed base correctly.
If pairing is unsuccessful, repeat the steps. Ensure the remote has fresh batteries and you are within close proximity to the bed base control box during the pairing process.
5. Operating Instructions
The Richmat HJH173 remote control features intuitive buttons for adjusting your bed base. The exact layout and functions may vary slightly based on the specific bed base model it is paired with, but common functions include:

Figure 2: Front view of the Richmat HJH173 remote control.
- Head Up/Down: Adjusts the head section of the bed base upwards or downwards.
- Foot Up/Down: Adjusts the foot section of the bed base upwards or downwards.
- Flat: Returns the bed base to a completely flat position.
- Zero Gravity (if applicable): Moves the bed to a preset position designed to relieve pressure.
- Memory Presets (M1, M2, etc., if applicable): Recalls custom saved bed positions.
Press and hold the desired button to move the bed section. Release the button when the desired position is reached.
6. Maintenance
- Cleaning: Wipe the remote control with a soft, dry cloth. Do not use liquid cleaners or abrasive materials.
- Battery Replacement: Replace batteries when the remote's response becomes sluggish or stops working. Always replace both batteries at the same time with new ones of the same type.
- Storage: If the remote will not be used for an extended period, remove the batteries to prevent leakage.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Remote not responding. | Dead or incorrectly inserted batteries. | Replace batteries with fresh ones, ensuring correct polarity. |
| Remote not responding. | Remote is not paired with the bed base. | Follow the "Pairing Instructions" in Section 4.2. |
| Remote only controls some functions. | Partial pairing or incompatibility. | Re-attempt pairing. Ensure the remote is fully compatible with your bed base model (check original remote buttons). |
| Bed base not moving. | Bed base is unplugged or power issue. | Check if the bed base is securely plugged into a working power outlet. |
If you continue to experience issues after following these troubleshooting steps, please contact customer support.
8. Specifications
- Model: HJH173
- Compatibility: Richmat, Leggett & Platt, TempurPedic adjustable bed bases using HJH173 remote.
- Power Source: 2 x AAA Batteries (not included)
- Item Weight: 9.6 ounces
- Package Dimensions: 9 x 7 x 3 inches
9. Warranty and Support
For warranty information or technical assistance, please contact the seller or manufacturer directly. Keep your purchase receipt as proof of purchase.
If you have any questions or require further assistance, please reach out to the customer support team through the platform where the product was purchased.