VEVOR 12V DC 6 GPM RV Water Pump

Instruction Manual

Model: LSDP1-060-070-42

Product Overview

This VEVOR 12V DC 6 GPM (22.7 L/min) 4-Chamber Self-Priming Diaphragm Water Pump is designed for on-demand water transfer in various applications including RVs, caravans, marine vessels, yachts, and car washing. It features an automatic pressure switch and delivers a maximum pressure of 70 PSI.

Key features include a high-flow rate, automatic start/stop functionality, low noise operation, and durable construction for reliable performance.

Safety Information

  • Ensure the power supply matches the pump's voltage (12V DC).
  • Do not operate the pump with flammable liquids.
  • Always disconnect power before performing any maintenance or installation.
  • The pump is not waterproof and is not intended for outdoor use where it may be exposed to direct water.
  • Install the pump in a dry, well-ventilated area.

Components Included

The package includes the following items:

  • 1 x Diaphragm Water Pump
  • 1 x Filter
  • 1 x PTFE Tape
  • 2 x Hose Adapters
  • 2 x Stainless Steel Hose Clamps
  • 1 x Allen Wrench
  • 1 x User Manual
Diagram showing the VEVOR RV water pump and its included accessories: filter, hose adapters, PTFE tape, stainless steel hose clamps, Allen wrench, and user manual.

Figure 1: Included Components and Product Dimensions

Specifications

Model NumberLSDP1-060-070-42
Voltage12V DC
Maximum Flow Rate6 GPM (22.7 L/min)
Maximum Pressure70 PSI
Self-Priming Height10 ft
Inlet/Outlet Diameter1/2 inch MNPT
Power204W
Item Weight5.73 lbs (2.6 kg)
MaterialPlastic

Setup

  1. Mounting the Pump: Securely mount the pump in a dry, protected location. Ensure adequate ventilation around the pump. The pump can be bolted directly to a flat surface.
  2. Hose Connection:
    • Attach the provided hose adapters to the pump's inlet and outlet ports.
    • Apply PTFE tape to the threads of the hose adapters for a leak-proof seal.
    • Connect standard 1/2-inch hoses to the adapters. Use the stainless steel hose clamps to reinforce connections.
    • Install the filter on the inlet side of the pump to prevent large particles from entering and damaging the pump.
    Diagram illustrating the hassle-free setup of the VEVOR water pump, showing the 1/2 inch hose inlet and outlet, thread sealing tape, hose adapters, and filter for large particles.

    Figure 2: Hassle-Free Setup and Connections

    Image showing the standard 1/2-inch hose connection with PTFE tape for leak-proof sealing, a filter to remove large particles, and a hose adapter for easy attachment.

    Figure 3: Standard 1/2-Inch Hose Connection Details

  3. Electrical Connection: Connect the pump to a 12V DC power source. Ensure correct polarity (red wire to positive, black wire to negative).
  4. Priming: The pump is self-priming up to 10 feet. Ensure the inlet hose is submerged in water before starting the pump for the first time to facilitate quicker priming. The pump supports short dry-run starts.

Operating Instructions

  1. Automatic Operation: This pump features an automatic pressure switch and bypass valve. When a faucet or outlet is opened, the pump will automatically start. When the faucet or outlet is closed, the pump will automatically stop.
  2. Adjusting Water Pressure: The water pressure can be adjusted using a hex wrench on the pressure switch. Refer to the detailed diagram for the adjustment screw location.
Image demonstrating the automatic start/stop function of the VEVOR water pump. It shows a faucet turning on, causing the pump to start, and a faucet turning off, causing the pump to stop.

Figure 4: Automatic Start/Stop Function

Diagram showing the pressure switch and bypass valve on the VEVOR water pump. It indicates how to open the pressure switch for adjustment and highlights its role in ensuring stable water flow.

Figure 5: Pressure Switch and Bypass Valve

Maintenance

  • Filter Cleaning: Regularly inspect and clean the inlet filter to prevent blockages and maintain optimal pump performance.
  • Winterization: In freezing temperatures, drain all water from the pump and hoses to prevent damage.
  • General Inspection: Periodically check all connections for leaks and ensure the mounting is secure.

Troubleshooting

ProblemPossible CauseSolution
Pump does not startNo power, incorrect wiring, faulty switchCheck power supply, verify wiring, inspect pressure switch.
Low flow or pressureClogged filter, air leak in inlet, kinked hose, low voltageClean filter, check inlet connections for leaks, straighten hoses, ensure adequate voltage.
Pump runs continuouslyLeak in system, pressure switch malfunction, air in systemCheck for leaks in plumbing, inspect pressure switch, bleed air from system.
Excessive noise/vibrationLoose mounting, air in system, debris in pumpSecure mounting, bleed air, inspect pump for foreign objects.

Warranty and Support

For warranty information or technical support, please contact VEVOR customer service. Keep your purchase receipt and model number (LSDP1-060-070-42) readily available for assistance.

You can find contact information on the official VEVOR website or through your retailer.

© 2026 VEVOR. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?