1. Introduction
This manual provides comprehensive instructions for the installation, operation, and maintenance of your YUHANUS Door Access Control System Kit. This all-in-one kit includes a power supply controller, a 1200lbs (500KG) magnetic lock, a stainless steel keypad, a remote control set, and an exit button, designed to provide a secure and convenient door entry solution. The system supports multiple unlock methods including password and 13.56MHz IC card access, and features a durable, IP68 waterproof keypad suitable for various indoor and outdoor environments.

Figure 1: Overview of the Door Access Control System Installation
2. Product Components
The YUHANUS Door Access Control System Kit includes the following components:
- Stainless Steel Keypad: IP68 waterproof, with backlit physical buttons.
- 1200lbs (500KG) Magnetic Lock: Provides strong locking force for enhanced security.
- Power Supply Controller: Manages power distribution and system functions.
- Remote Control Set: Includes two 2-button remotes for wireless door operation.
- Exit Button: For convenient manual exit from the inside.
- IC Cards/Key Fobs: For card-based access.

Figure 2: Complete Kit Components
3. Setup and Installation
3.1 Wiring Diagram
Carefully follow the wiring diagram to connect all components correctly. Ensure all power is disconnected before beginning installation.

Figure 3: Wiring Diagram of the Access Control System
3.2 Component Installation
- Keypad: Mount the stainless steel keypad on the exterior side of the door or gate. Its IP68 rating ensures resistance to water and dust.
- Magnetic Lock: Install the 1200lbs magnetic lock on the door frame and the armature plate on the door itself. Ensure proper alignment for maximum holding force.
- Power Supply: Connect the power supply controller to a stable AC power source (110-240V).
- Exit Button: The exit button features a detachable back box, allowing for either surface-mount or flush-mount installation on the interior side of the door.
- Remote Receiver: Connect the remote receiver module to the power supply controller as per the wiring diagram.

Figure 4: Keypad Dimensions

Figure 5: Power Supply Unit

Figure 6: Magnetic Lock Dimensions

Figure 7: Exit Button Dimensions

Figure 8: Remote Receiver Module

Figure 9: Remote Control
4. Operation
The access control system offers multiple ways to unlock the door:
- Unlock by Indoor Button: Press the exit button from the inside to momentarily release the magnetic lock.
- Unlock by PIN: Enter your programmed PIN on the keypad, followed by '#', to unlock the door.
- Unlock by IC Card: Swipe a programmed 13.56MHz IC card over the keypad to unlock the door.
- Unlock by Remote Control: Press the unlock button on the remote control to wirelessly release the magnetic lock.
Video 1: Demonstration of unlocking methods including indoor button, PIN, IC card, and remote control.
5. Programming
5.1 Setting Public PIN
To set a public PIN for the keypad:
- Press *.
- Enter the default master code (usually 999999).
- Press #.
- Enter 9.
- Enter your new public PIN (4-6 digits).
- Press #.
- Re-enter your new public PIN.
- Press # to confirm.
5.2 Adding More Cards
To add additional IC cards to the system:
- Press *.
- Enter the default master code (usually 999999).
- Press #.
- Enter 1.
- Swipe the new IC card over the keypad.
- Repeat for all cards you wish to add.
- Press * to exit programming mode.
6. Maintenance
To ensure optimal performance and longevity of your access control system, consider the following maintenance tips:
- Regular Cleaning: Wipe the keypad and magnetic lock surfaces with a soft, damp cloth. Avoid abrasive cleaners or solvents.
- Check Connections: Periodically inspect all wiring connections to ensure they are secure and free from corrosion.
- Magnetic Lock Alignment: Verify that the magnetic lock and armature plate remain properly aligned. Misalignment can reduce holding force.
- Test Functionality: Regularly test all unlock methods (PIN, card, remote, exit button) to confirm proper operation.
7. Troubleshooting
If you encounter issues with your access control system, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Door does not unlock with PIN/Card. | Incorrect PIN, unprogrammed card, power issue, wiring error. | Verify PIN, ensure card is programmed, check power supply, inspect wiring connections. |
| Magnetic lock not engaging. | No power to lock, misalignment, faulty lock. | Check power supply output, adjust lock and armature plate alignment, contact support if lock is faulty. |
| Remote controls not working. | Remote battery low, remote not paired, receiver issue. | Replace remote battery, re-pair remote with receiver, check receiver wiring. |
| Keypad backlight not working. | Power issue, internal fault. | Check power supply, contact support. |
8. Specifications
| Feature | Specification |
|---|---|
| Brand | YUHANUS |
| Model Number | YH-K03-H1401-500KG |
| Magnetic Lock Holding Force | 1200lbs (500KG) |
| Keypad Material | 304 Stainless Steel |
| Keypad IP Rating | IP68 Waterproof |
| Unlock Methods | Password, 13.56MHz IC Card, Remote Control, Exit Button |
| Power Source | AC 110-240V |
| Output Voltage | DC 12V (4A) |
| Item Dimensions (L x W x H) | 11.81 x 7.09 x 3.94 inches |
| Item Weight | 8 Pounds |
9. Warranty and Support
For warranty information and technical support, please refer to the product packaging or contact YUHANUS customer service. Keep your purchase receipt for warranty claims.