BSIDE ACM91

BSIDE ACM91 Digital Clamp Meter User Manual

Model: ACM91 | Brand: BSIDE

1. Introduction

The BSIDE ACM91 is a versatile digital clamp meter designed for accurate measurement of AC/DC current, AC/DC voltage, resistance, capacitance, frequency, and temperature. It features True RMS measurement, auto-ranging, Non-Contact Voltage (NCV) detection, and a Live Check function, making it an essential tool for electrical professionals and DIY enthusiasts. This manual provides detailed instructions for safe and effective use of your ACM91 clamp meter.

2. Safety Information

Always adhere to basic safety precautions when using this instrument to avoid personal injury or damage to the meter or equipment under test. Read all safety information before operating the meter.

  • Do not exceed the maximum input limits for any function.
  • Use extreme caution when working with voltages above 60V DC or 30V AC RMS. Such voltages pose a shock hazard.
  • Before measuring current, ensure the circuit is de-energized and the clamp jaws are properly closed around a single conductor.
  • Disconnect the test leads from the meter before opening the battery cover.
  • Do not operate the meter if it appears damaged or if the case is open.
  • Ensure the test leads are in good condition, without any damaged insulation.
  • Always use the correct function and range for measurements.

3. Product Overview

3.1 Components

The BSIDE ACM91 clamp meter consists of the following main components:

  • Clamp Jaws: For non-contact AC/DC current measurement.
  • Function Dial/Buttons: To select measurement modes and functions.
  • LCD Display: Shows measurement readings, units, and indicators.
  • Input Jacks: For connecting test leads for voltage, resistance, capacitance, frequency, and temperature measurements.
  • NCV Sensor: For non-contact voltage detection.
  • Flashlight: For illuminating the work area.
BSIDE ACM91 Digital Clamp Meter front view

Figure 3.1: Front view of the BSIDE ACM91 Digital Clamp Meter, showing the clamp jaws, function dial, display, and buttons.

BSIDE ACM91 Clamp Meter with test leads and carrying case

Figure 3.2: The BSIDE ACM91 Clamp Meter packaged with its red and black test leads, a temperature probe, a screwdriver, and a protective carrying case.

4. Setup

4.1 Battery Installation

The ACM91 clamp meter is powered by batteries (not included). To install or replace batteries:

  1. Ensure the meter is powered off and disconnect all test leads from the input jacks.
  2. Locate the battery compartment cover on the back of the meter.
  3. Use a screwdriver to loosen the screw(s) on the battery cover and remove the cover.
  4. Insert the new batteries, observing the correct polarity (+ and -) as indicated inside the compartment.
  5. Replace the battery cover and secure it with the screw(s).

4.2 Powering On/Off

Press the power button (U symbol) to turn the meter on or off. The meter features an auto-power-off function to conserve battery life if inactive for a certain period.

5. Operating Instructions

The ACM91 features intelligent automatic range selection, simplifying operation by automatically matching the optimal measurement range.

5.1 AC/DC Current Measurement (Clamp)

This function allows for non-contact current measurement, enhancing safety and efficiency.

  1. Turn the function dial to the AC or DC current measurement mode (indicated by A~ or A= symbols).
  2. Press the clamp trigger to open the jaws.
  3. Enclose only one conductor of the circuit within the clamp jaws. Ensure the jaws are fully closed.
  4. Read the current value on the LCD display.
BSIDE ACM91 Clamp Meter measuring current on a circuit breaker panel

Figure 5.1: The clamp meter in use, measuring current by clamping around a single wire within a circuit breaker panel.

5.2 AC/DC Voltage Measurement

  1. Insert the red test lead into the INPUT jack and the black test lead into the COM jack.
  2. Turn the function dial to the voltage measurement mode (indicated by V~ for AC or V= for DC). The meter will automatically detect AC or DC voltage.
  3. Connect the test probes in parallel to the circuit or component you wish to measure.
  4. Read the voltage value on the LCD display.
BSIDE ACM91 Clamp Meter measuring voltage with test leads

Figure 5.2: The clamp meter measuring voltage using the red and black test leads connected to a power source.

5.3 Resistance Measurement

  1. Ensure the circuit is de-energized before measuring resistance.
  2. Insert the red test lead into the INPUT jack and the black test lead into the COM jack.
  3. Turn the function dial to the resistance mode (indicated by Ω symbol).
  4. Connect the test probes across the component to be measured.
  5. Read the resistance value on the LCD display.

5.4 Capacitance Measurement

  1. Ensure the capacitor is fully discharged before measurement to prevent damage to the meter.
  2. Insert the red test lead into the INPUT jack and the black test lead into the COM jack.
  3. Turn the function dial to the capacitance mode (indicated by F symbol).
  4. Connect the test probes across the capacitor terminals.
  5. Read the capacitance value on the LCD display.

5.5 Frequency Measurement

  1. Insert the red test lead into the INPUT jack and the black test lead into the COM jack.
  2. Turn the function dial to the frequency mode (indicated by Hz symbol).
  3. Connect the test probes in parallel to the circuit where frequency is to be measured.
  4. Read the frequency value on the LCD display.

5.6 Temperature Measurement

  1. Insert the temperature probe into the INPUT and COM jacks, observing polarity if applicable.
  2. Turn the function dial to the temperature mode (indicated by °C/°F symbol).
  3. Place the tip of the temperature probe on or near the object whose temperature you wish to measure.
  4. Read the temperature value on the LCD display.

5.7 Non-Contact Voltage (NCV) Detection

The NCV function allows for quick detection of AC voltage without direct contact.

  1. Turn the function dial to the NCV mode.
  2. Move the NCV sensor (located at the top of the clamp jaws) close to the conductor or outlet.
  3. The meter will emit an audible beep and the NCV indicator light will flash when AC voltage is detected.

5.8 Live Wire Check

The Live Check function helps identify live wires in a circuit.

  1. Turn the function dial to the Live Check mode (indicated by LIVE symbol).
  2. Insert the red test lead into the INPUT jack. The black test lead is not used for this function.
  3. Touch the red probe to the conductor or terminal you suspect is live.
  4. If the wire is live, the display will show 'LIVE' and an audible alarm will sound.

5.9 True RMS Function

The ACM91 features True RMS measurement, which accurately captures the effective value of AC voltage and current, even for non-sinusoidal waveforms. This provides more precise readings compared to average-responding meters, especially in circuits with electronic loads.

Four testing scenarios for BSIDE ACM91 Clamp Meter

Figure 5.3: Various testing scenarios including DC current test, AC voltage/frequency test, car battery voltage test (DC voltage), and car current test (DC current) using the ACM91 clamp meter.

6. Maintenance

6.1 Cleaning

Wipe the meter's case with a damp cloth and a mild detergent. Do not use abrasives or solvents. Keep the input jacks free of dust and debris.

6.2 Storage

If the meter is not used for an extended period, remove the batteries to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.

6.3 Battery Replacement

When the battery indicator appears on the display, replace the batteries as described in Section 4.1. Using the meter with low battery power may result in inaccurate readings.

7. Troubleshooting

  • Meter does not power on: Check battery installation and ensure batteries are not depleted. Replace if necessary.
  • No reading or 'OL' displayed: The measured value may be out of the selected range. The ACM91 is auto-ranging, but ensure the correct function is selected. For current, ensure only one conductor is clamped.
  • Inaccurate readings: Check battery level. Ensure test leads are properly connected and not damaged. Verify the correct measurement function is selected. Ensure the clamp jaws are fully closed for current measurements.
  • NCV/Live Check not working: Ensure the function is correctly selected and the sensor/probe is positioned correctly.

8. Specifications

ParameterValue
Model NumberACM91
Display TypeDigital Only
Measuring Current Range (AC/DC)6A / 60A / 100A
Measuring Voltage Range (AC/DC)6V / 60V / 600V
Measuring Resistance Range600Ω / 6kΩ / 60kΩ / 600kΩ / 6MΩ / 60MΩ
Measuring Capacitance Range600uF / 6000uF
Measuring Inductance RangeN/A
Operating Temperature0-40°C
Dimensions179mm x 67mm x 36mm
Weight137g
Power SourceBattery Powered (Batteries not included)
CertificationCE

9. Warranty and Support

For warranty information and technical support, please refer to the documentation provided with your purchase or contact the manufacturer directly. Keep your purchase receipt as proof of purchase for warranty claims.

Manufacturer: YHNNH

© 2025 BSIDE. All rights reserved.