1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pibbs PS-55-V Venice Pedicure Spa Chair. This professional-grade pedicure spa chair is designed for salon and spa environments, featuring a vibrating chair top, built-in LED lighting, a magnetic jet system, and adjustable components for client comfort and technician convenience.
2. Safety Information
WARNING: Read all instructions before use. Failure to follow these instructions may result in injury or damage to the product.
- Do not exceed the maximum weight recommendation of 350 pounds.
- Always use adjustable parts with caution to avoid injury.
- Ensure all electrical connections are properly grounded and meet local electrical codes.
- Verify all plumbing connections are secure to prevent leaks.
- Keep water and electrical components separate. Do not operate if electrical components are wet.
- This product is intended for professional use in salons and spas.
3. Components Overview
The Pibbs PS-55-V Venice Pedicure Spa Chair consists of the following main components:
- Chair Top: Upholstered seat with backrest, armrests, and integrated vibration massage.
- Base Unit: Two-tone fiberglass base housing the pedicure basin and plumbing.
- Pedicure Basin: Integrated foot bath with magnetic jet system and LED lighting.
- Footrest: Adjustable front footrest.
- Control Panel/Remote: For massage functions and other adjustments.
- Plumbing Fixtures: cUPC-certified faucet, chrome shower head, and hose.

4. Installation and Setup
Proper installation is crucial for the functionality and longevity of your pedicure spa chair. It is recommended that installation be performed by a qualified professional.
4.1. Unpacking
Carefully remove all components from the packaging. Inspect for any shipping damage. Retain packaging for future transport or return if necessary.
4.2. Positioning
Place the spa chair on a level, stable surface. Ensure adequate space around the unit for client access and technician movement. Consider the location of water supply and drainage lines, as well as electrical outlets.

4.3. Plumbing Connections
- Connect the hot and cold water supply lines to the appropriate inlets on the spa unit. Use thread sealant tape for secure, leak-free connections.
- Connect the drain line to the spa unit's drainage system. Ensure a proper seal and slope for efficient water removal. The unit features an overflow drainage system to prevent spills.
- Install the cUPC-certified faucet and chrome shower head with hose according to the manufacturer's instructions.
- Test all plumbing connections for leaks before final placement.
4.4. Electrical Connections
- Connect the power cord to a grounded electrical outlet that meets the product's power requirements.
- Ensure the power supply is stable and protected by a ground fault circuit interrupter (GFCI) as required by local electrical codes.
5. Operating Instructions
Familiarize yourself with the various functions of your Pibbs PS-55-V Venice Pedicure Spa Chair to provide optimal service.
5.1. Chair Adjustments
The chair offers multiple adjustments for client comfort and technician access:
- Swivel: The chair top can swivel to allow easy client entry and exit.
- Recline: Use the lever or button (depending on model variation) to recline the backrest to a desired angle.
- Forward/Back Slide: The chair can slide forward and backward to adjust the distance from the pedicure basin.
- Adjustable Footrest: The front footrest can be smoothly raised and lowered to support the client's feet at an ergonomic height during service.

5.2. Vibration Massage
The chair top features a 6-function vibration massage system for client relaxation.
- Locate the massage control remote, typically found in a side pocket or integrated into the armrest.
- Press the 'Power' button to activate the massage system.
- Select desired massage functions (e.g., pulse, wave, ripple), zones (e.g., back, lumbar, seat), and intensity levels using the corresponding buttons on the remote.
- Adjust the timer if available.

5.3. Magnetic Jet System
The dual high-powered magnetic jet system provides a quiet and invigorating whirlpool experience.
- Fill the pedicure basin with warm water to the appropriate level.
- Locate the jet activation button, usually on the side of the basin.
- Press the button to start the whirlpool action.
- Press again to turn off the jets.

5.4. Built-in LED Lighting
The pedicure basin features built-in LED lights for enhanced ambiance.
- Locate the LED light control button, typically near the jet activation button.
- Press the button to cycle through light colors or turn the lights on/off.
6. Maintenance
Regular maintenance ensures the longevity and hygienic operation of your pedicure spa chair.
6.1. Cleaning the Magnetic Jet System
The magnetic jet system is designed for easy cleaning:
- After each use, drain the basin completely.
- Remove the magnetic jet head by twisting or pulling it out (refer to specific model instructions if needed).
- Clean the jet head and the basin thoroughly with an approved disinfectant solution.
- Rinse the basin and jet head with clean water.
- Reinstall the magnetic jet head.
6.2. General Cleaning
- Wipe down all vinyl surfaces of the chair with a mild, non-abrasive cleaner and a soft cloth. Avoid harsh chemicals that may damage the upholstery.
- Clean the fiberglass base with a non-abrasive cleaner.
- Regularly check and clean the overflow drainage system to prevent blockages.
7. Troubleshooting
Refer to the table below for common issues and their solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Chair does not power on. | Power cord unplugged, circuit breaker tripped, GFCI tripped. | Check power cord connection, reset circuit breaker, reset GFCI. |
| Magnetic jet not working. | Jet head not properly installed, power issue, debris in jet. | Ensure jet head is secure, check power, remove and clean jet head. |
| Vibration massage not functioning. | Remote control battery low/dead, power issue, loose connection. | Replace remote batteries, check power, ensure connections are secure. |
| Water leaks from basin. | Loose plumbing connections, damaged seal. | Tighten all plumbing connections, inspect seals for damage and replace if necessary. |
8. Specifications
Key technical specifications for the Pibbs PS-55-V Venice Pedicure Spa Chair:
| Feature | Detail |
|---|---|
| Brand | Pibbs |
| Model Name | PIB-PS-55-V Venice |
| Product Dimensions (D x W x H) | 24"D x 33"W x 35"H |
| Material | Vinyl (Upholstery), Fiberglass (Base) |
| Color | Black |
| Maximum Weight Recommendation | 350 Pounds |
| Massage Type | 6-Function Vibration Massage |
| Jet System | Dual High-Powered Magnetic Jets |
| Lighting | Built-in LED Lights |
| Plumbing | cUPC-certified faucet, chrome shower head, hose, overflow drainage system |
| Item Weight | 185 pounds |
9. Warranty and Customer Support
9.1. Warranty
The Pibbs PS-55-V Venice Pedicure Spa Chair comes with a 1-Year Warranty. Please retain your proof of purchase for warranty claims. The warranty covers manufacturing defects under normal use conditions. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact Pibbs customer support.
9.2. Customer Support
For any questions, assembly assistance, troubleshooting, or warranty inquiries, please contact Pibbs customer support. Our dedicated team is available to provide prompt assistance.
Contact information can typically be found on the Pibbs official website or on your purchase receipt.
10. Product Demonstration Video
Watch this video to see the Pibbs Pedicure Spa Chairs in a salon setting, demonstrating their aesthetic and functional integration into a professional environment.