1. Introduction
This manual provides essential instructions for the safe and effective operation of your MDSS BP-S10 Digital Automatic Upper Arm Blood Pressure Monitor. Please read this manual thoroughly before using the device and retain it for future reference. This device is designed for home use to measure systolic and diastolic blood pressure and pulse rate.

Image 1.1: The MDSS BP-S10 Blood Pressure Monitor being used on a patient's upper arm, demonstrating its application for home health tracking.
2. Important Safety Information
- Consult your physician before using this device if you have any medical conditions.
- Do not use this device for diagnostic purposes. Always consult a healthcare professional for interpretation of results.
- Do not adjust medication based on measurements from this monitor without consulting a doctor.
- Keep the device out of reach of children and pets.
- Avoid using the device in areas with strong electromagnetic fields.
- Do not disassemble or attempt to repair the device yourself.
3. What's in the Box
Upon opening the package, please verify that all components are present and undamaged:
- MDSS BP-S10 Blood Pressure Monitor Unit
- Universal Arm Cuff (22-42 cm)
- 4 AAA Batteries
- USB Cable
- User Manual (this document)

Image 3.1: Visual representation of the items included in the MDSS BP-S10 Blood Pressure Monitor package.
4. Product Overview
The MDSS BP-S10 monitor features a large LCD display and intuitive buttons for easy operation. Key components include:
- LCD Display: Shows systolic, diastolic, pulse rate, and other indicators.
- ON/OFF Button: Powers the device on and off, initiates measurement.
- SET Button: Used for setting date, time, and user profiles.
- MEM Button: Accesses stored measurement records.
- Cuff Connector Port: Where the air tube from the cuff connects to the monitor.
- Battery Compartment: Located on the bottom or side for AAA batteries.
- USB Port: For optional power supply.

Image 4.1: Detailed views of the MDSS BP-S10 monitor, showing its display, buttons (SET, ON/OFF, MEM), and overall design.
5. Setup
5.1. Installing Batteries
- Open the battery compartment cover on the back or side of the monitor.
- Insert four (4) AAA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
Alternatively, the device can be powered via the USB cable (adapter not included).

Image 5.1: The MDSS BP-S10 monitor with its power accessories, including AAA batteries and a USB cable.
5.2. Connecting the Arm Cuff
- Locate the air tube on the arm cuff.
- Insert the connector at the end of the air tube firmly into the air jack on the side of the monitor unit.
- Ensure the connection is secure to prevent air leakage during measurement.
5.3. Setting Date and Time (Initial Setup)
Refer to the on-screen prompts or specific instructions in the device's display for setting the date and time using the SET button. This ensures accurate record-keeping.
6. Operating Instructions
6.1. Preparing for Measurement
- Avoid eating, drinking alcohol, smoking, exercising, or bathing for 30 minutes before measurement.
- Rest for at least 5 minutes before taking a measurement.
- Sit in a comfortable position with your back supported and feet flat on the floor.
- Place your arm on a flat surface so the cuff is at heart level.
6.2. Applying the Arm Cuff
- Slide your arm through the cuff loop.
- Position the cuff so the air tube runs down the center of your inner arm, aligned with your middle finger.
- The bottom edge of the cuff should be approximately 2-3 cm above your elbow joint.
- Wrap the cuff snugly around your upper arm. Ensure it is not too tight or too loose. The universal cuff fits arm circumferences from 22 to 42 cm.
6.3. Taking a Measurement
- Press the ON/OFF button to power on the device. The monitor will automatically begin inflation.
- Remain still and silent during the measurement.
- Once the measurement is complete, the systolic pressure, diastolic pressure, and pulse rate will be displayed on the LCD screen.
- The integrated voice feature will announce the results clearly.
- The measurement will be automatically stored in the device's memory.

Image 6.1: The simple one-touch operation of the MDSS BP-S10 monitor, activated by pressing the ON/OFF button.

Image 6.2: The MDSS BP-S10 monitor's voice alert feature, providing audible results for enhanced accessibility.
6.4. Memory Function
The monitor can store up to 99 readings for two users. To access stored readings:
- Press the MEM button when the device is off or displaying results.
- Repeatedly press MEM to scroll through previous measurements.
- To switch between User 1 and User 2 memory, use the SET button (refer to device display for specific user selection method).
7. Maintenance and Storage
- Cleaning: Wipe the monitor and cuff with a soft, dry cloth. If necessary, use a cloth lightly dampened with water and mild soap, then wipe dry. Do not use abrasive cleaners or immerse the device in water.
- Storage: Store the device in a clean, dry place, away from direct sunlight, extreme temperatures, and humidity.
- Batteries: Remove batteries if the device will not be used for an extended period to prevent leakage.
- Cuff Care: Ensure the cuff is not twisted or sharply bent during storage.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on. | Batteries are dead or incorrectly inserted. | Replace batteries with new ones, ensuring correct polarity. Check USB connection if using external power. |
| Error message on display (e.g., "Err"). | Cuff not applied correctly, movement during measurement, or air leakage. | Reapply cuff snugly. Remain still and silent. Check cuff connection to monitor. |
| Inaccurate or inconsistent readings. | Improper cuff placement, incorrect body position, or recent activity. | Ensure proper cuff placement and body position. Rest for 5 minutes before re-measuring. Avoid talking or moving. |
| Voice feature not working. | Volume too low or feature disabled. | Check device settings for voice volume. Refer to the specific device menu for voice activation/deactivation. |
If problems persist, contact customer support.
9. Specifications
- Model: BP-S10
- Measurement Method: Oscillometric
- Cuff Size: Universal Arm Cuff (22-42 cm)
- Memory: 2 users x 99 sets of readings
- Power Source: 4 x AAA batteries or USB power
- Item Weight: Approximately 600 g (monitor unit)
- Manufacturer: 101MedicalDevices
- Country of Origin: India
10. Warranty and Support
For warranty information or technical support, please refer to the warranty card included with your product or contact the manufacturer directly. Contact details for 101MedicalDevices may be found on the product packaging or their official website.
Manufacturer: 101MedicalDevices
Contact: 9873213502