Berrcom AET-F372, ET003

Berrcom Digital Thermometer Bundle User Manual

Models: AET-F372 & ET003

Introduction

Welcome to your Berrcom Digital Thermometer Bundle. This manual provides detailed instructions for the safe and effective use of both the Berrcom AET-F372 Rechargeable Digital Thermometer and the Berrcom ET003 Forehead and Ear Thermometer. Please read this manual thoroughly before use and keep it for future reference.

Product Overview

Berrcom AET-F372 Rechargeable Digital Thermometer

The AET-F372 is a waterproof, rechargeable digital thermometer designed for comfortable and accurate temperature measurement. It features a clear LED display, beep alarm, last memory display, and automatic shutdown function.

Berrcom AET-F372 Rechargeable Digital Thermometer in its charging case

Image: The Berrcom AET-F372 thermometer shown in its sleek, white charging case, displaying a temperature reading.

Berrcom ET003 Forehead and Ear Thermometer

The ET003 is a versatile thermometer capable of measuring temperature from the forehead and ear, suitable for all ages. It offers switchable Celsius/Fahrenheit units, an automatic shut-off function, and a fever alarm with backlight indicators.

Berrcom ET003 Forehead and Ear Thermometer

Image: The Berrcom ET003 thermometer, white with blue buttons, displaying a temperature reading on its green backlit screen.

Safety Information

Setup and First Use

Berrcom AET-F372

  1. Charging: Place the thermometer in its charging case with the charging terminals facing down. Ensure it is fully charged before first use. A full charge ensures optimal performance.
  2. Power On/Off: The device typically powers on automatically when removed from the case. It features an automatic shutdown function to conserve battery.
  3. Unit Selection: The default unit is usually Fahrenheit. Refer to the device's specific instructions for changing between Celsius and Fahrenheit, if applicable.
Instructions for charging and removing Berrcom AET-F372 thermometer

Image: A diagram illustrating how to correctly insert the AET-F372 thermometer into its charging case and how to gently press to remove it.

Berrcom ET003

  1. Battery Installation: Open the battery compartment (usually located at the bottom or back) and insert two AAA batteries, ensuring correct polarity. Close the compartment securely.
  2. Power On: Press the "START" button to turn on the thermometer. The display will show a brief self-test.
  3. Unit Selection (℃/℉): With the device on, press and hold the "MOD" button for a few seconds to switch between Celsius (℃) and Fahrenheit (℉). The selected unit will be displayed.
  4. Silent Mode: Long press the "MOD" button for approximately 6 seconds to enter or exit silent mode. This is useful for taking measurements without disturbing a sleeping child.
Berrcom ET003 thermometer with removable cap

Image: The Berrcom ET003 thermometer with its blue protective cap being removed, indicating readiness for use for ear measurements.

Operating Instructions

Berrcom AET-F372

  1. Measurement: Remove the thermometer from its charging case. Place the thermometer in the desired measurement location (e.g., orally under the tongue, axillary under the armpit).
  2. Reading: Wait for the beep alarm, indicating the measurement is complete. The temperature will be clearly displayed on the LED screen.
  3. Memory: The device automatically stores the last measurement for easy recall.
Berrcom AET-F372 thermometer displaying 98.24F

Image: A close-up of the Berrcom AET-F372 thermometer displaying a temperature of 98.24°F on its digital screen.

Berrcom ET003

The ET003 offers multiple measurement modes for various applications:

Berrcom ET003 showing 4 measurement modes: Room, Object, Forehead, Ear

Image: A visual guide demonstrating the four measurement modes of the Berrcom ET003: Room Temperature, Object Temperature, Forehead Body Temperature, and Ear Body Temperature.

  1. Forehead Measurement: Ensure the protective cap is on. Press the "START" button and gently scan the thermometer across the forehead, maintaining close contact with the skin.
  2. Ear Measurement: Remove the protective cap. Gently insert the probe into the ear canal. Press the "START" button.
  3. Object/Room Measurement: Select the appropriate mode using the "MOD" button. Point the thermometer at the object or towards the room for non-contact temperature measurement.
  4. Fever Alarm: The screen backlight will turn red and a short beep will sound if the measured temperature exceeds the normal range (e.g., 100.4°F / 38°C). A green backlight indicates a normal temperature.
Berrcom ET003 displaying green and red backlight indicators for temperature

Image: The Berrcom ET003 thermometer showing its intelligent fever alarm system with green backlight for normal temperatures (e.g., 96.8°F) and red backlight for elevated temperatures (e.g., 100.4°F).

Maintenance and Cleaning

Berrcom AET-F372

The AET-F372 is IPX65 waterproof, allowing for easy cleaning. It can be wiped with water and cleaned with medical alcohol after or before each use to ensure hygiene and accuracy.

Store the thermometer in its charging case when not in use. This protects the device from damage and keeps it charged and ready for the next use.

Berrcom ET003

Clean the probe tip with a cotton swab or soft cloth lightly moistened with medical alcohol. Gently wipe the surface of the device with a soft, dry cloth. Do not immerse the device in water or use abrasive cleaners.

Store the thermometer in a cool, dry place, away from direct sunlight, extreme temperatures, and high humidity. Ensure the protective cap is on when storing to protect the probe.

Troubleshooting

Specifications

Berrcom AET-F372

  • Model: AET-F372
  • Type: Rechargeable Digital Thermometer
  • Waterproof Rating: IPX65
  • Display: Clear Large LED
  • Features: Beep alarm, Last memory display, Automatic shutdown function.
  • Power Source: Rechargeable battery (integrated).

Berrcom ET003

  • Model: ET003
  • Type: Forehead and Ear Thermometer
  • Measurement Modes: Forehead, Ear, Object, Room temperature.
  • Unit: Celsius (℃) / Fahrenheit (℉) switchable.
  • Automatic Shut-off: Approximately 30 seconds.
  • Fever Alarm: Yes, with red backlight indicator.
  • Silent Mode: Yes.
  • Power Source: 2 x AAA batteries (not included or pre-installed, depending on packaging).

Warranty and Support

For detailed warranty information, product registration, or technical support, please refer to the official Berrcom website or contact Berrcom customer service directly. Contact details are typically found on the product packaging or the manufacturer's official website. Please have your product model numbers (AET-F372, ET003) and purchase date available when contacting support.

Related Documents - AET-F372, ET003

Preview Berrcom ET005 Infrared Ear and Forehead Thermometer User Manual
User manual for the Berrcom ET005 digital infrared thermometer. Learn about its features, how to accurately measure body temperature from the ear or forehead, maintenance, technical specifications, and warranty information provided by Guangzhou Berrcom Medical Device Co., Ltd.
Preview Berrcom ET003 Ear Thermometer User Manual
Comprehensive user manual for the Berrcom ET003 Ear Thermometer, detailing features, usage instructions, safety precautions, troubleshooting, and technical specifications for accurate temperature measurement.
Preview Berrcom JXB-311 Non-contact Infrared Thermometer User Manual
Comprehensive user manual for the Berrcom JXB-311 non-contact infrared thermometer, covering setup, operation, troubleshooting, specifications, and warranty information.
Preview Berrcom JXB-195 Non-contact Infrared Thermometer Instruction Manual
Comprehensive instruction manual for the Berrcom JXB-195 non-contact infrared thermometer. Learn about its intended use, safety precautions, operation modes, technical specifications, and maintenance for accurate forehead temperature readings in home and clinical settings.
Preview Berrcom JXB-182 Non-Contact Infrared Thermometer Instruction Manual
Comprehensive instruction manual for the Berrcom JXB-182 non-contact infrared thermometer. Covers intended use, safety precautions, operating instructions, technical specifications, maintenance, and disposal for accurate forehead temperature measurement in household and clinical settings.
Preview Berrcom Digital Thermometer User Manual
User manual for the Berrcom Digital Thermometer, providing instructions on intended use, warnings, how to take a temperature, product description, operation, cleaning, technical specifications, troubleshooting, and EMC declaration.