1. Introduction
Thank you for choosing the LifeBasis Air Quality Monitor. This device is designed to provide real-time monitoring of various indoor air quality parameters, helping you maintain a healthier living environment. This manual provides essential information on how to set up, operate, and maintain your air quality monitor.

Image 1.1: LifeBasis Air Quality Monitor
2. Product Overview
2.1 Key Features
- 11-in-1 Monitoring: Real-time detection of AQI, CO2, PM1.0, PM2.5, PM10, Particles, HCHO, TVOC, Temperature, and Humidity.
- High-Precision Sensors: Equipped with NDIR infrared CO2 sensor, laser particle sensor, semiconductor sensor, photoelectric sensor, and temperature/humidity sensor for accurate readings.
- Color and Sound Alarms: Visual color-coded indicators (Good, Moderate, Poor, Unhealthy) and an audible alarm for exceeding preset thresholds.
- Clear LCD Display: Easy-to-read screen with adjustable brightness.
- Long Battery Life: Built-in 2500mAh battery provides 11-12 hours of continuous use, rechargeable via Type-C port.
- Portable Design: Suitable for various indoor environments including homes, offices, basements, and vehicles.

Image 2.1: Overview of 11-in-1 monitoring capabilities.
2.2 Device Components
The LifeBasis Air Quality Monitor features a clear LCD display and intuitive controls.

Image 2.2: Detailed view of the LCD display and its indicators.
- Sound On Icon: Indicates if audible alerts are active.
- AQI: Air Quality Index reading.
- CO2: Carbon Dioxide concentration.
- Particles: General particle count.
- PM1.0, PM2.5, PM10: Particulate Matter concentrations.
- HCHO: Formaldehyde concentration.
- TVOC: Total Volatile Organic Compounds concentration.
- Battery Indicator: Shows current battery level.
- Temperature (°C/°F): Ambient temperature.
- Humidity (%): Relative humidity.
- Alarm Indicator: Blinks when an alarm is triggered or during charging.
- Multi-Function Button: Used for power, unit changes, and confirmation.
- Up/Down Buttons: For navigation and adjusting settings.
- Left/Right Buttons: For navigation and switching display modes.
3. Setup
3.1 Unboxing
Upon opening the package, ensure all components are present:
- 1 x LifeBasis Air Quality Monitor
- 1 x Instruction Manual
- 1 x Type-C Charging Cable

Image 3.1: Package contents including the monitor, manual, and charging cable.
3.2 Initial Charging
Before first use, charge the device for at least 5 minutes using the provided Type-C cable. Connect the cable to the monitor's Type-C port and a compatible USB power source.
4. Operation
4.1 Power On/Off
- To power on, press and hold the Multi-Function button.
- To power off, press and hold the Multi-Function button again.
4.2 Basic Controls

Image 4.1: Functions of the Multi-Function button and directional buttons.
- Change Temperature Units (°C/°F): Single press the Multi-Function button.
- Select Function or Adjust Brightness: Single press the Up/Down buttons.
- Sound On/Off: Press and hold the Left button.
- Enter Settings Interface: Press and hold the Left and Right buttons simultaneously.
- Switch Display: Single press the Left/Right buttons to cycle through different measurement values (e.g., PM2.5, Particles, TVOC, HCHO, PM1.0, PM10).

Image 4.2: How to switch between different measurement displays.
5. Calibration
For accurate readings, especially for CO2, calibration is recommended before initial use and periodically thereafter.
5.1 CO2 Calibration Procedure

Image 5.1: Steps for performing CO2 calibration.
- Charge the device for at least 5 minutes before using it for the first time.
- Place the monitor in a well-ventilated outdoor area for more than 10 minutes with the power on.
- Enter the calibration interface (press and hold Left and Right buttons simultaneously), then select "Yes" for calibration.
- The calibration will complete with a long beep from the buzzer.
6. Understanding Readings and Alarms
6.1 Air Quality Indicators
The monitor uses a color-coded system to indicate air quality levels for various parameters:
- Green: Good air quality.
- Yellow: Moderate pollution.
- Orange: Poor air quality.
- Red: Unhealthy air quality.

Image 6.1: Example of the multicolor indicator for PM2.5 levels.
6.2 Reference Table for Air Pollution Grades
Refer to the table below for specific concentration ranges corresponding to each air quality grade.

Image 6.2: Detailed reference table for AQI, PM1.0, PM2.5, PM10, CO2, HCHO, and TVOC levels.
6.3 Audible and Visual Alarms
When any monitored value exceeds its normal threshold, the device will emit a ticking alarm sound, the indicator light will flash continuously, and the interface color will change to reflect the severity.

Image 6.3: Illustration of the intelligent reminder system with default alarm values.
Default alarm values are:
- AQI: 100
- CO2: 1500 PPM
- PM1.0: 75 µg/m³
- PM2.5: 75 µg/m³
- PM10: 150 µg/m³
- HCHO: 0.1 mg/m³
- TVOC: 0.5 mg/m³
7. Maintenance
7.1 Charging the Device
The monitor is equipped with a built-in 2500mAh battery. Use the provided Type-C cable for charging. A full charge takes approximately 6 hours and provides 11-12 hours of standby time.

Image 7.1: Charging specifications and device dimensions.
7.2 Care and Safety Guidelines

Image 7.2: Important safety and care instructions.
- Prevent Soaking: Do not place the product in bathrooms or areas where it may be drenched by water.
- Prevent Strong Vibration: Avoid strong shock or vibration, such as dropping the device.
- Stay Away from Volatile Substances: Do not place the product near volatile substances like perfume, alcohol, or mosquito coils, as these can interfere with readings.
- Prevent Obstruction of Gas Ports: Do not insert sharp, flammable, or metal objects into the monitor or air inlet to avoid short-circuiting or damage.
8. Troubleshooting
- Inaccurate Readings: Ensure the device has been properly calibrated, especially for CO2. Perform calibration in a well-ventilated outdoor area. Avoid placing the monitor near sources of strong odors or chemicals.
- Device Not Turning On: Check if the battery is charged. Connect the device to a power source using the Type-C cable and try again.
- No Sound/Alarm: Check if the sound function is enabled (press and hold the Left button).
- Screen Not Responding: Try restarting the device by holding the Multi-Function button. If the issue persists, ensure the battery is charged.
- HCHO/TVOC Readings Seem Low/Zero: These sensors may require a baseline period to stabilize. Ensure the device is used in a consistent environment for some time after calibration.
9. Specifications
| Feature | Specification |
|---|---|
| Product Dimensions | 0.95"D x 2.92"W x 6.3"H (2.41 x 7.42 x 16.0 cm) |
| Item Weight | 6.08 ounces (172.37 grams) |
| Battery | 1 Lithium Ion battery (included), 2500mAh |
| Power Source | Battery Powered, Type-C Charging Port |
| Alarm Type | Audible |
| Number of Items | 1 |
| Color | Black |
| Manufacturer | Life Basis |
10. Warranty and Support
LifeBasis is committed to providing quality products and customer satisfaction. If you encounter any questions or issues with your product, please contact LifeBasis customer support for assistance. We aim to provide a solution as soon as possible.