The ERICKHILL ROOK 800P is a versatile 2-in-1 thermometer designed for accurate temperature measurement across a wide range of applications. It combines both non-contact infrared (IR) measurement and contact probe (PR) measurement, offering flexibility and precision for various scenarios. This manual provides essential information for the safe and effective use of your device.

Figure 1.1: ERICKHILL ROOK 800P Thermometer Overview
2. Safety Information
Please read all safety warnings and instructions carefully before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Do not use for human body temperature measurement. This device is designed for industrial and household object temperature measurement only.
- Avoid direct or indirect exposure of the infrared sensor to strong light sources.
- Do not immerse the device in water or expose it to excessive moisture.
- Keep the device away from children.
- Do not attempt to disassemble or modify the device. Repairs should only be performed by qualified personnel.
- Dispose of batteries according to local regulations.

Figure 2.1: Important Safety Warning: Not for Human Body Temperature
3. Product Features
- Dual Measurement Modes: Offers both non-contact infrared (IR) measurement (-50°C to 800°C) and contact probe (PR) measurement (-50°C to 300°C).
- High Accuracy: Reliable measurements with ±2% error for temperatures above 100°C and ±2°C for temperatures below 100°C.
- Fast Response: 0.5-second high-speed response for real-time temperature readings.
- Adjustable Emissivity: Emissivity adjustable from 0.1 to 0.99 to suit various material surfaces.
- Distance-to-Spot Ratio: 12:1 D:S ratio for accurate targeting from a distance.
- User-Friendly Display: Large LCD screen with backlight for clear visibility in various lighting conditions.
- Data Functions: MAX/MIN temperature display, Data HOLD function, and °C/°F unit switching.
- Power Saving: Automatic power-off after 30 seconds of inactivity.

Figure 3.1: Key Features of the ROOK 800P
4. Components
The ERICKHILL ROOK 800P package includes:
- ERICKHILL ROOK 800P Thermometer
- Contact Probe
- Instruction Manual
- Storage Bag (not explicitly mentioned in JSON but implied by images)
- AAA Batteries (2x, implied by 'battery powered' and '12 hours use with 2 AAA batteries')
5. Setup
5.1 Battery Installation
- Locate the battery compartment cover on the handle of the thermometer.
- Open the cover.
- Insert two AAA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
5.2 Attaching the Contact Probe
If contact measurement is required, plug the contact probe into the designated port on the side of the thermometer. Ensure it is securely connected.
6. Operating Instructions
6.1 Power On/Off
- To power on, press the measurement trigger.
- The device will automatically power off after 30 seconds of inactivity to conserve battery life.
6.2 Switching Measurement Modes (IR/PR)
Press the IR/PR button to switch between non-contact infrared (IR) mode and contact probe (PR) mode. The active mode will be indicated on the LCD screen.
6.3 Taking Non-Contact (IR) Measurements
- Ensure the thermometer is in IR mode.
- Point the infrared sensor towards the target object. Maintain a distance that allows the measurement spot to be within the target area (12:1 D:S ratio).
- Press and hold the measurement trigger. The temperature reading will appear on the LCD screen.
- Release the trigger to hold the reading.
6.4 Taking Contact (Probe) Measurements
- Ensure the contact probe is securely attached and the thermometer is in PR mode.
- Insert the probe into the substance or object to be measured.
- The temperature reading will appear on the LCD screen.

Figure 6.1: Dual Measurement in Action
6.5 Adjusting Emissivity
Emissivity (EMS) is a crucial setting for accurate IR measurements, as different materials emit infrared energy differently. The ROOK 800P allows adjustment from 0.1 to 0.99.
- In IR mode, press the MODE button to cycle through functions until EMS is displayed.
- Use the up/down arrow buttons to adjust the emissivity value.
- Refer to common emissivity tables for typical materials (e.g., wood: 0.94, water: 0.93, metal: 0.70).

Figure 6.2: Emissivity Settings for Different Materials
6.6 Unit Switching (°C/°F)
Press the °C/°F button to switch between Celsius and Fahrenheit temperature units.
6.7 MAX/MIN/HOLD Functions
While taking measurements, press the MODE button to cycle through additional functions such as displaying the maximum (MAX) or minimum (MIN) temperature recorded during a scan, or to hold (HOLD) the current reading on the screen.

Figure 6.3: Backlight for Enhanced Readability
7. Applications
The ERICKHILL ROOK 800P is suitable for a wide range of applications, including but not limited to:
- Cooking and Food Preparation: Measuring surface temperatures of ovens, grills, and internal temperatures of food.
- HVAC and Refrigeration: Checking temperatures of air conditioning vents, refrigerators, and freezers.
- Automotive Maintenance: Diagnosing engine temperatures, exhaust systems, and other vehicle components.
- Electrical and Industrial: Inspecting electrical panels, circuit boards, and machinery for overheating.
- Home Inspection: Identifying insulation issues, floor heating performance, and general temperature monitoring.
- Hobby and DIY: Various temperature checks for crafts, soldering, and other projects.








8. Maintenance
8.1 Cleaning
- Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Keep the infrared lens clean and free from dust or debris for accurate readings.
8.2 Storage
- Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures.
- Remove batteries if the device will not be used for an extended period.
9. Troubleshooting
- No Display: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate Readings (IR Mode):
- Ensure the emissivity setting is correct for the target material.
- Clean the infrared lens.
- Ensure the target is larger than the measurement spot size at the given distance.
- Inaccurate Readings (Probe Mode): Ensure the probe is fully inserted into the substance and has reached thermal equilibrium.
- Device Not Responding: Remove and reinsert batteries. If the issue persists, contact customer support.
10. Specifications
| Feature | Specification |
|---|---|
| Brand | ERICKHILL |
| Model Name | ROOK 800P |
| IR Temperature Range | -50°C to 800°C (-58°F to 1472°F) |
| Probe Temperature Range | -50°C to 300°C (-58°F to 572°F) |
| Accuracy (IR & PR) | ±2% or ±2°C (±3.6°F), whichever is greater |
| Response Time | 0.5 seconds |
| Distance-to-Spot Ratio (D:S) | 12:1 |
| Emissivity | Adjustable 0.1 to 0.99 |
| Display Type | LCD with Backlight |
| Power Source | 2 x AAA Batteries |
| Automatic Power Off | After 30 seconds of inactivity |
| Product Length | 14.5 cm |
| Indoor/Outdoor Use | Yes |
| Country of Origin | China |
11. Warranty and Support