VENTS GK 150 LD

VENTS-US GK 150 LD 6-inch Through-Wall Exhaust Fan User Manual

Model: GK 150 LD | Brand: VENTS-US

1. Introduction

This manual provides detailed instructions for the safe and efficient installation, operation, and maintenance of your VENTS-US GK 150 LD 6-inch through-wall exhaust fan. Please read this manual thoroughly before using the product and retain it for future reference.

The VENTS-US GK 150 LD is designed to improve indoor air quality by removing moisture, harmful fumes, vapors, odors, and common indoor air pollutants. It is suitable for various applications including bathrooms, basements, garages, workshops, and other areas requiring direct through-wall ventilation.

2. Safety Information

WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:

  • Read all instructions before installing or servicing this fan.
  • Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
  • Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Before servicing or cleaning the unit, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  • Do not use this fan with any solid-state speed control device unless specifically approved for use with this fan.
  • This fan is not intended for use in kitchens or areas with high grease content.
  • Ensure proper ventilation is provided for combustion air needed for fuel-burning equipment to prevent back-drafting.

3. Package Contents

Verify that all components are present and undamaged before proceeding with installation.

  • VENTS-US GK 150 LD Exhaust Fan Unit
  • Durable White (ABS) Sleeve
  • Front Panel
  • Adjustable Telescopic Duct
  • External Grille (Sleek Model)
  • Power Cord with Plug

4. Product Overview

The VENTS-US GK 150 LD is a 6-inch through-wall exhaust fan designed for efficient air extraction. It features a sleek design and includes an adjustable telescopic duct for easy installation in various wall thicknesses.

Front view of VENTS-US GK 150 LD exhaust fan

Figure 1: Front view of the VENTS-US GK 150 LD exhaust fan, showing the sleek design.

Back view of VENTS-US GK 150 LD exhaust fan

Figure 2: Back view of the VENTS-US GK 150 LD exhaust fan, showing the internal components and duct connection.

Side view of VENTS-US GK 150 LD exhaust fan

Figure 3: Side view of the VENTS-US GK 150 LD exhaust fan, illustrating the depth of the unit.

Video 1: Product overview of the VENTS-US GK 150 LD ventilation fan, highlighting its features and design.

Video 2: Demonstration of how the GK Exhaust Fan can help improve air quality in various settings.

Video 3: A full 360-degree view of the GK 150 LD Exhaust Fan, showcasing its complete design.

5. Specifications

FeatureSpecification
BrandVENTS-US
ModelGK 150 LD
Duct Diameter6 inches
Airflow Performance109 CFM
Noise Level3.0 Sones
Voltage120 Volts
Wattage32.9 watts max
Installation TypeThrough The Wall
Product Dimensions8.06"D x 6.06"W x 6.5"H
Item Weight6 pounds
ColorWhite
Special FeaturesImproves airflow, minimizes moisture/dampness, removes fumes/odors, low operating costs, space-saving design.
CertificationETL, HVI Certified
VENTS-US GK 150 LD dimensions diagram

Figure 4: Dimensions of the VENTS-US GK 150 LD exhaust fan, including extendable PVC ducting.

6. Setup and Installation

The VENTS-US GK 150 LD fan is designed for straightforward through-wall installation. It can be either plugged into a standard outlet or hardwired by a qualified electrician.

6.1 Site Selection

Choose a location on an exterior wall where the fan can effectively exhaust air directly outside. Ensure there are no obstructions on either side of the wall where the fan will be installed.

Ventilation kit applications in a garage and other rooms

Figure 5: Example applications for the VENTS-US GK series, including garages, basements, workshops, and bathrooms.

6.2 Wall Preparation

  1. Determine the desired height and position for the fan.
  2. Mark the center point for the duct opening.
  3. Using an appropriate hole saw, cut a 6-inch diameter hole through the wall at the marked location. Ensure the hole is clean and smooth.
Diagram showing through-wall fan installation with power cable and junction box

Figure 6: Installation diagram illustrating the fan, power cable, and junction box within the wall.

6.3 Fan Assembly and Mounting

  1. Insert the adjustable telescopic duct into the cut hole. Adjust its length to match the wall thickness (up to 11 inches).
  2. Attach the fan unit to the interior side of the wall, ensuring the duct connects securely to the fan's collar. Secure the fan to the wall using appropriate fasteners (not included).
  3. On the exterior side, attach the external grille to the duct, ensuring a tight seal to prevent air leakage and backdrafts.

6.4 Electrical Connection

The GK 150 LD comes with a corded plug for direct connection to a standard 120V/60Hz electrical outlet. Alternatively, the unit can be hardwired into your electrical system by a qualified electrician. Refer to local electrical codes for proper wiring procedures.

IMPORTANT: Always ensure power is disconnected at the circuit breaker before performing any electrical work.

7. Operating Instructions

Once installed and connected to power, the VENTS-US GK 150 LD fan is ready for operation.

  • Power On/Off: If plugged in, simply plug the fan into an active outlet. If hardwired, use the designated wall switch to turn the fan on or off.
  • Continuous Operation: This fan is designed for continuous operation to maintain consistent air quality.
  • Airflow Direction: The fan is designed to exhaust air from the interior to the exterior. Ensure proper installation for the intended airflow direction.
Illustration of car exhaust being removed by a wall-mounted fan

Figure 7: Visual representation of the fan effectively removing harmful fumes, such as car exhaust from a garage.

8. Maintenance

Regular maintenance ensures optimal performance and longevity of your VENTS-US GK 150 LD exhaust fan.

8.1 Cleaning the Fan and Grille

WARNING: Disconnect power at the service panel before cleaning or performing any maintenance.

  1. Periodically wipe down the exterior of the fan and the front panel with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  2. For the external grille, remove any accumulated debris, dust, or insects to ensure unrestricted airflow.
  3. The fan motor is designed for long-term operation and is maintenance-free. Do not attempt to lubricate the motor.

9. Troubleshooting

If you experience issues with your VENTS-US GK 150 LD exhaust fan, refer to the following table for common problems and solutions.

ProblemPossible CauseSolution
Fan does not operateNo power supply; loose wiring; tripped circuit breaker.Check power connection, ensure plug is fully inserted or wiring is secure. Reset circuit breaker.
Reduced airflowBlocked external grille; internal fan blades obstructed.Clean the external grille. Disconnect power and inspect fan blades for obstructions.
Excessive noiseLoose mounting; foreign object in fan; motor issue.Ensure fan is securely mounted. Disconnect power and check for foreign objects. If noise persists, contact support.
Backdraft occurringDamper malfunction (if applicable); strong external wind.Inspect the backdraft damper for proper function. Consider installing an external hood with a damper if not already present.

10. Warranty and Support

The VENTS-US GK 150 LD exhaust fan comes with a Limited Warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official VENTS-US website.

For technical support, replacement parts, or further assistance, please contact VENTS-US customer service:

  • Website: www.vents-us.com
  • Email: [Insert Customer Service Email Here]
  • Phone: [Insert Customer Service Phone Number Here]

Related Documents - GK 150 LD

Preview Vents D Axial Fan User's Manual
Comprehensive user's manual for the Vents D axial fan, covering delivery set, installation, operation, technical maintenance, troubleshooting, and manufacturer's warranty. Includes technical specifications and safety guidelines.
Preview VENTS M1/MA Series Axial Fans - User Manual and Installation Guide
Comprehensive user manual and installation guide for VENTS M1/MA series axial fans. Covers safety, operation, features, and specifications for residential ventilation. Includes models V, T, H, Turbo, 100mm, 125mm, 150mm.
Preview VENTS TT Series Round Duct Fans - Technical Specifications and Applications
Comprehensive technical guide for VENTS TT Series round duct fans, detailing construction, motor features, speed control options, performance curves, noise data, dimensions, and installation examples for residential, commercial, and industrial ventilation systems.
Preview VENTS VK Series In-Line Centrifugal Fans User Manual
User's manual for VENTS VK Series in-line centrifugal fans, covering installation, operation, maintenance, safety instructions, and warranty information. Features include electronic speed and temperature control (TSC module).
Preview VENTS Stone Concealed Installation Fan User Manual
User manual for the VENTS Stone concealed installation fan, providing detailed information on installation, operation, maintenance, troubleshooting, and warranty. Includes model specifications and safety guidelines.
Preview VENTS VUT 100 P mini / VUE 100 P mini User Manual - Ventilation & Heat Recovery
Discover the VENTS VUT 100 P mini and VUE 100 P mini air handling units. This user manual guides through installation, operation, maintenance, and troubleshooting for efficient ventilation and heat recovery in residential and commercial spaces. Learn about safety, technical data, and system benefits.