1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your VENTS-US GK 150 MA 6-inch Through-the-Wall Exhaust Fan. Please read this manual thoroughly before installation and use to ensure safe and efficient operation. Retain this manual for future reference.
The VENTS-US GK 150 MA is designed to improve indoor air quality by effectively removing moisture, harmful fumes, vapors, odors, humidity, and common indoor air contaminants. It is an ideal ventilation solution for spaces lacking existing ductwork, such as bathrooms, basements, garages, and other areas requiring direct through-the-wall exhaust.
2. Safety Information
WARNING: To reduce the risk of fire, electric shock, or injury to persons, observe the following:
- Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
- Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back-drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
- When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
- Ducted fans must always be vented to the outdoors.
- Do not use this fan with any solid-state speed control device.
- This unit is not intended for use in kitchens.
- Always disconnect power from the unit before servicing.
3. Package Contents
Verify that all components are present and undamaged before proceeding with installation.
- VENTS-US GK 150 MA Exhaust Fan Unit
- Durable White (ABS) Sleeve
- Front Panel with Built-in Louvers
- Adjustable Telescopic Duct (PVC)
- External Vent Cover/Grill
- Power Cord with Plug (for plug-in option)
- Mounting Hardware (screws, anchors)
4. Product Features
- Effective Contaminant Removal: Efficiently exhausts vehicle exhaust gases, fumes, paint vapors, odors, and other indoor air pollutants.
- Through-the-Wall Solution: Designed for direct installation through exterior walls, eliminating the need for complex ductwork.
- Backdraft Protection: Features thermally actuated louvers that automatically seal the fan when off, preventing drafts and outside air leakage (exclusive to GK MA series).
- Energy Efficient: Operates on a maximum of 35.2 watts, suitable for continuous use with low energy consumption.
- Quiet Operation: Engineered for a sound level of 2.7 Sones for minimal noise disruption.
- Flexible Power Options: Can be plugged into a standard wall outlet or hardwired for permanent installation.
- Moisture Control: Improves airflow to reduce humidity, condensation, and damp conditions.
- Durable Construction: Made from robust materials for long-lasting performance.
5. Setup and Installation
The VENTS-US GK 150 MA is designed for straightforward through-the-wall installation. Ensure you have the necessary tools and follow local electrical codes.
5.1 Dimensions and Components Overview
Familiarize yourself with the fan's components and dimensions before beginning installation.
Figure 1: VENTS-US GK 150 MA Exhaust Fan - Main View
This image shows the complete VENTS-US GK 150 MA exhaust fan unit, including the internal fan housing and the external grille, ready for through-the-wall installation.
Figure 2: GK 150 MA Dimensions
This diagram illustrates the key dimensions of the GK 150 MA fan, including the extendable PVC ducting which can adjust from 6" to 11.5" to accommodate various wall thicknesses. The fan housing measures 6.5" x 8.375" x 7.6825".
5.2 Installation Steps
- Select Location: Choose an appropriate location on an exterior wall, ensuring it is away from obstructions and allows for proper air exhaust. Consider the fan's dimensions and required clearances.
- Prepare Wall Opening: Based on the fan's duct diameter (6 inches), create a circular opening through the wall. Use the provided template or refer to the dimensions in Figure 2. Ensure the opening is clean and smooth.
- Install Ducting: Insert the adjustable telescopic PVC duct through the prepared wall opening. Adjust its length to match the wall thickness.
- Mount Fan Unit: Secure the main fan unit to the interior side of the wall, ensuring the fan's exhaust aligns with the ducting. Use appropriate mounting hardware.
- Attach External Grille: On the exterior side of the wall, attach the external vent cover/grille. Ensure it is securely fastened and provides a weather-tight seal.
- Electrical Connection:
- Plug-in Option: If using the corded plug, simply plug the fan into a standard 120V/60Hz electrical outlet.
- Hardwire Option: For permanent installation, a qualified electrician should hardwire the unit to the building's electrical system, following all local codes.
- Test Operation: Once installed, power on the fan to verify proper operation and airflow.
Figure 3: Power Cable Connection Diagram
This diagram illustrates how the power cable connects to the fan unit and can be routed to a house junction box for hardwiring or plugged into an outlet.
5.3 Installation Video (Similar Model)
Video 1: Vents-US GK 150 LD Ventilation Fan Product Overview
This video provides a product overview and demonstrates the components of a similar VENTS-US through-the-wall fan (GK 150 LD model), which can offer insights into the installation process for the GK 150 MA.
Video 2: Vents-US GK 125 MA Ventilation Fan Product Overview
This video presents an overview of the VENTS-US GK 125 MA (5-inch model), showcasing its features and components, which are largely similar to the 6-inch GK 150 MA model.
Video 3: 6 Inch Through-the-Wall Exhaust Fan Installation Overview
This video provides a general overview of a 6-inch through-the-wall exhaust fan, which can be helpful for understanding the basic installation principles.
Video 4: 6 Inch Wall Mounted Exhaust Fan Overview
This video offers another perspective on a 6-inch wall-mounted exhaust fan, demonstrating its features and potential applications.
6. Operating Instructions
The VENTS-US GK 150 MA is designed for simple operation. Once properly installed and connected to power, the fan can be activated.
- Power On/Off: If plugged into an outlet, use the wall switch controlling that outlet to turn the fan on or off. If hardwired, use the dedicated wall switch installed by your electrician.
- Automatic Louvers: The fan features thermally actuated louvers. When the fan is powered on, these louvers will automatically open to allow airflow. When the fan is powered off, they will close to prevent backdrafts and air leakage.
- Continuous Operation: The fan is designed for continuous operation to maintain consistent air quality.
Video 5: Vents-US GK 150 MA Ventilation Fan Product Overview
This video provides a comprehensive overview of the VENTS-US GK 150 MA, demonstrating its features and operation, including the automatic louvers.
Video 6: How the GK Exhaust Fan Can Help You
This video highlights the benefits and functionality of the GK exhaust fan series, illustrating how it improves air quality and ventilation.
7. Maintenance
Regular maintenance ensures optimal performance and longevity of your VENTS-US GK 150 MA exhaust fan. Always disconnect power before performing any maintenance.
- Cleaning the Grille and Fan Blades: Periodically remove the external grille and gently clean the fan blades and interior surfaces with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- Check for Obstructions: Ensure that the ducting and external grille are free from debris, insects, or other obstructions that could impede airflow.
- Inspect Wiring: Annually, have a qualified person inspect the electrical wiring for any signs of wear or damage.
8. Troubleshooting
If you experience issues with your VENTS-US GK 150 MA fan, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Fan does not turn on. | No power, loose wiring, faulty switch. | Check power supply, ensure plug is secure or wiring is correct. Test wall switch. |
| Low airflow. | Blocked grille/duct, dirty fan blades. | Clean grille and fan blades. Check ducting for obstructions. |
| Excessive noise. | Loose components, debris in fan, motor issue. | Ensure all mounting screws are tight. Clean fan blades. If noise persists, contact support. |
| Louvers not opening/closing. | Obstruction, thermal actuator malfunction. | Check for physical obstructions. If problem continues, contact support. |
If the problem persists after attempting these solutions, please contact VENTS-US customer support.
9. Specifications
| Feature | Detail |
|---|---|
| Brand | VENTS |
| Model Name | VENTS GK 150 MA (120V/60Hz) |
| Item Weight | 6 pounds |
| Product Dimensions | 6.5"D x 8.37"W x 7.68"H |
| Airflow (CFM) | 176 CFM |
| Noise Level | 2.7 Sones |
| Installation Type | Through The Wall |
| Voltage | 120 Volts |
| Wattage | 35.2 watts (max) |
| Color | White |
| Certification | ETL |
| Special Features | Backdraft protection with built-in thermally actuated louvers, improves airflow, removes fumes/odors, low operating costs. |
10. Warranty and Support
For warranty information or technical support, please refer to the documentation included with your product or visit the official VENTS-US website. Keep your purchase receipt as proof of purchase.