Thank you for choosing the LANCHEZ 1.2HP 6000GPH Automatic Sump Pump. This submersible pump is designed for efficient water removal from various environments such as pools, basements, garden ponds, and flooded areas. Featuring a powerful 1.2HP motor and 6 customizable operating modes, it offers reliable performance for both clean and dirty water applications. Please read this manual thoroughly before operation to ensure safe and optimal use of your pump.

2. Safety Information

Always prioritize safety when operating electrical equipment. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Electrical Safety: Ensure the power supply matches the pump's voltage (115V). Always plug into a grounded outlet. Do not use extension cords unless absolutely necessary and ensure they are rated for outdoor use and the pump's power requirements. Never operate the pump with a damaged power cord.
  • Submersion: The pump must be fully submerged in water during operation to prevent overheating and dry running.
  • Water Type: This pump is suitable for clean and dirty water, capable of passing solid particles up to 1.4 inches. Avoid pumping flammable, corrosive, or explosive liquids.
  • Temperature: Do not use the pump in water exceeding 95°F (35°C).
  • Handling: Always use the integrated handle to lift or move the pump. Never pull the pump by its power cord.
  • Children and Pets: Keep children and pets away from the pump and the area of operation.
  • Maintenance: Disconnect the pump from the power source before performing any maintenance or cleaning.

3. Product Features

  • Powerful Performance: 1.2HP motor, capable of draining up to 6000 GPH and lifting water up to 35 feet vertically.
  • Low Water Removal: Bottom suction design allows water removal down to 0.04 inches from the surface.
  • Versatile Water Handling: Suitable for clean or dirty water, passing solid particles up to 1.4 inches.
  • 6 Operating Modes: Offers flexible control with 4 adjustable start water levels and 4 adjustable stop water levels, plus timed and continuous operation.
  • Durable Construction: Made from reinforced engineering thermoplastic casing for corrosion and abrasion resistance.
  • Safety Features: Built-in thermal overload protector prevents motor burnout during dry running. IPX8 waterproof certification ensures reliable performance.
  • Easy Connection: Features a 1-inch discharge and includes a 1-1/2-inch elbow adapter and multi-purpose hose connector compatible with 1-inch, 1-1/4-inch, 1-1/2-inch, or NPT 1-inch hoses.
  • Portable Design: Integrated handle and 16-foot power cord for easy transport and placement.

4. Technical Specifications

LANCHEZ Sump Pump Technical Specifications

Image showing the LANCHEZ sump pump with its key technical specifications listed, including voltage, power, amps, protection class, max head, max flow rate, and power cord length.

SpecificationValue
Model NumberQ850B256A
Power1.2 HP
Voltage115 V
Maximum Flow Rate6000 GPH (100 Gallons Per Minute)
Maximum Lifting Height35 Feet
Product Dimensions (L x W x H)10.3" x 8.3" x 12.6"
MaterialReinforced Thermoplastic
Power Cord Length16 Feet
Max. Particle Size1.4 inches
Minimum Suction Level0.04 inches
Protection ClassIPX8

5. Setup and Installation

5.1 Unpacking

Carefully remove the pump and all accessories from the packaging. Check for any damage during transit. The package should include the 1.2HP Sump Pump, various adapters, and this manual.

5.2 Connecting the Discharge Hose

Adapter Installation for LANCHEZ Sump Pump

Image illustrating the various hose adapters included with the LANCHEZ sump pump and how they connect to different hose sizes (1", 1-1/4", 1-1/2", NPT 1").

  1. The pump features a 1-inch discharge outlet.
  2. Use the provided 1-1/2-inch elbow adapter or the multi-purpose hose connector to attach your discharge hose.
  3. The multi-purpose connector is compatible with 1-inch, 1-1/4-inch, 1-1/2-inch, or NPT 1-inch hoses. Cut the adapter to the desired size for a secure fit.
  4. Ensure all connections are tight to prevent leaks.

5.3 Adjusting the Pump Base

LANCHEZ Sump Pump Adjustable Base

Image highlighting the adjustable base of the LANCHEZ sump pump, showing how it can be configured for different maximum grain sizes and low water removal capabilities.

The pump features an adjustable base to accommodate different water conditions and particle sizes. Adjust the base by stepping on the pump base bracket and adjusting the height of the pump base as needed. This allows for optimal performance whether dealing with clean water or dirty water containing larger particles.

5.4 Placement

Place the pump on a stable, level surface in the area to be drained. Ensure the pump is fully submerged in water before starting operation. For initial startup, it is recommended to submerge the pump at a tilted angle to help expel any trapped air, which can affect pumping efficiency.

6. Operating Modes

The LANCHEZ sump pump offers 6 operating modes for various pumping needs. The control panel on the pump features buttons and indicator lights for easy mode selection and water level adjustment.

LANCHEZ Sump Pump Automatic Modes

Image displaying the LANCHEZ sump pump with its control panel, highlighting the Auto Mode, Timed Mode, Manual Mode, and Ultra-low Water Level Mode options.

6.1 Default Mode (Automatic Operation)

Upon plugging in the pump, the indicator lights will turn on, and the pump will enter the default automatic mode. In this mode, the pump automatically starts when the water reaches a maximum sensing level (level 3) and stops when it reaches a minimum suction level (level 1).

Video demonstrating the default automatic operation mode of the LANCHEZ sump pump, showing it activating and deactivating based on water levels.

6.2 Adjusting Water Levels

You can customize the start and stop water levels:

  • The upper buttons (levels 4, 5, 6) set the maximum water level for pump activation.
  • The lower buttons (levels 1, 2, 3) set the minimum water level for pump deactivation.
  • To set an automatic startup water level, press and hold any button (e.g., level 4) until the light is set. The pump will then activate when water reaches this level.

6.3 Draining to the Lowest Level

To drain water to the absolute lowest possible level (0.04 inches):

  1. Press and hold buttons 1 and 2 simultaneously.
  2. The pump will operate until the water level is minimized.
  3. Automatic shutdown occurs 3 minutes after the cycle ends.

6.4 Timed Pumping

For scheduled pumping times:

  1. Press and hold buttons 4, 5, or 6 to set a scheduled pumping time of 10 or 20 minutes.
  2. The indicator lights will count down the delay by turning off every 100/200 seconds, indicating the remaining time.

6.5 Continuous Operation

For continuous pumping, bypassing automatic shut-off:

  1. Hold buttons 5 and 6 simultaneously.
  2. The pump will operate continuously until manually turned off or a default mode is resumed.

7. Maintenance

Regular maintenance ensures the longevity and efficiency of your pump.

  • Cleaning: Periodically clean the pump's intake screen to remove debris that may obstruct water flow. Disconnect power before cleaning.
  • Storage: When not in use, especially during freezing temperatures, drain all water from the pump and store it in a dry, protected area.
  • Inspection: Regularly inspect the power cord for any signs of damage. If damaged, do not use the pump and contact customer support.

8. Troubleshooting

If you encounter issues, refer to the following common solutions:

  • Pump not drawing water or low flow:
    • Ensure the pump is fully submerged and tilted to expel internal air during initial startup.
    • Check the intake screen for blockages and clear any debris.
    • Verify the discharge hose is not kinked or blocked.
  • Pump not starting:
    • Check if the pump is properly plugged into a working, grounded outlet.
    • Ensure the water level has reached the set activation level in automatic modes.
    • The thermal overload protector may have tripped due to overheating. Disconnect power, allow the pump to cool, and then reconnect.
  • Pump running continuously in automatic mode:
    • Verify the stop water level is set correctly.
    • Check for debris interfering with the water level sensors.
LANCHEZ Sump Pump Caution and Air Expulsion

Image showing important cautions for the LANCHEZ sump pump, including tilting the pump to expel air if flow is low and not pulling the power cord.

If problems persist after attempting these solutions, please contact LANCHEZ Customer Support.

9. Warranty and Customer Support

The LANCHEZ 1.2HP 6000GPH Automatic Sump Pump comes with a 36-month warranty from the date of purchase, ensuring your peace of mind.

LANCHEZ prioritizes customer satisfaction. Our dedicated customer support team is available 24/7 to address any questions, concerns, or issues you may have regarding your product. Please do not hesitate to reach out for assistance.

For support, please visit the official LANCHEZ website or refer to the contact information provided with your purchase.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.