1. Introduction
This manual provides comprehensive instructions for the safe and efficient operation of your DEWENWILS Outdoor Digital Power Strip Timer. This device is designed to automate the power supply to outdoor electrical appliances, offering convenience and energy management. Please read this manual thoroughly before installation and use, and retain it for future reference.
2. Safety Information
To prevent personal injury or property damage, always observe the following safety precautions:
- Outdoor Use Only: This timer is specifically designed for outdoor applications and features a weatherproof cover. Ensure the cover is securely closed when in use.
- Electrical Rating: Do not exceed the maximum electrical rating of 125 Volts, 15 Amps, 1875 Watts Resistive, 1/3 HP. Overloading can cause overheating and fire.
- Grounding: Always connect the timer to a properly grounded 3-prong outlet. The timer itself has 3 grounded outlets.
- Water Protection: While weatherproof, avoid submerging the unit in water. Ensure the outlets are not exposed to direct water spray when in use.
- Cord Integrity: Regularly inspect the 6-inch SJTW 14-3 grounded cord for any damage. Do not use if the cord is frayed or damaged.
- Children and Pets: Keep the device out of reach of children and pets.
- Disconnection: Disconnect power before performing any maintenance or when the unit is not in use for extended periods.
3. Product Overview
The DEWENWILS Outdoor Digital Power Strip Timer features a robust design suitable for various outdoor applications. It includes a digital display for programming and multiple grounded outlets.
Image 1: DEWENWILS Outdoor Digital Power Strip Timer. The image displays the timer unit with its weatherproof housing open, revealing the digital display and three grounded outlets. A ground stake is attached, and a power cord with a 3-prong plug is visible. An additional indoor-style timer with a single outlet is also shown for comparison, though the manual focuses on the outdoor unit.
Key Components:
- Digital Display: Shows current time, day, and programming status.
- Control Buttons: MODE, +, -, SET, PROG (Program), WEEK, HOUR, MIN, R/RECALL, CLOCK, ON/AUTO/OFF.
- Grounded Outlets: Three (3) outlets for connecting appliances.
- Weatherproof Housing: Protects internal components from water and dust.
- Ground Stake: For secure installation in soft ground.
- Power Cord: 6-inch SJTW 14-3 grounded cord with 3-prong plug.
4. Setup and Initial Configuration
4.1 Physical Installation
- Assemble Stake: Connect the ground stake to the bottom of the timer unit.
- Positioning: Choose a suitable outdoor location where the timer can be securely wedged into the ground. Ensure it is close enough to a grounded outdoor power outlet.
- Plug In: Plug the timer's power cord into a grounded outdoor electrical outlet.
4.2 Setting Current Time
The timer operates on a 24-hour system (military time) and does not display AM/PM indicators.
- Enter Clock Mode: Press and hold the CLOCK button for approximately 3 seconds until the display flashes.
- Set Day: While in Clock Mode, press the WEEK button repeatedly to select the current day (e.g., MO, TU, WE, TH, FR, SA, SU).
- Set Hour: Press the HOUR button repeatedly to set the current hour (00-23).
- Set Minute: Press the MIN button repeatedly to set the current minute (00-59).
- Exit Clock Mode: Press the CLOCK button once to save the settings and return to normal display.
5. Operating Instructions
5.1 Programming On/Off Settings
The timer supports up to 20 ON/OFF programs. Each program consists of an ON time and an OFF time.
- Enter Program Mode: Press the PROG button. The display will show "1 ON".
- Set Program 1 ON Time:
- Press WEEK to select the day(s) for this program. Options include individual days, weekdays, weekends, or all days.
- Press HOUR to set the desired ON hour.
- Press MIN to set the desired ON minute.
- Set Program 1 OFF Time: Press PROG again. The display will show "1 OFF". Repeat the steps above to set the OFF day(s), hour, and minute.
- Continue Programming: Press PROG to cycle through programs 2 ON, 2 OFF, up to 20 ON, 20 OFF. Repeat the setting steps for each desired program.
- Exit Program Mode: Press the CLOCK button to save all programs and return to the current time display.
5.2 Random Function
The random function can be used to make your home appear occupied by turning lights ON at random times. It activates up to 5 events daily, with each event remaining ON for 15 minutes.
- Activate Random: Press the MODE button until "RANDOM" appears on the display.
- Deactivate Random: Press the MODE button again to cycle through modes until "RANDOM" disappears.
5.3 Manual Override (ON/AUTO/OFF)
The ON/AUTO/OFF button allows you to manually control the timer's output, overriding programmed settings temporarily.
- AUTO: The timer operates according to the programmed ON/OFF settings. This is the default mode.
- ON: The timer's outlets are continuously ON, regardless of programmed settings.
- OFF: The timer's outlets are continuously OFF, regardless of programmed settings.
Press the ON/AUTO/OFF button repeatedly to cycle through these modes.
6. Maintenance
The DEWENWILS Outdoor Digital Power Strip Timer requires minimal maintenance.
- Cleaning: Disconnect the timer from power before cleaning. Wipe the exterior with a soft, damp cloth. Do not use harsh chemicals or abrasive cleaners.
- Inspection: Periodically check the power cord and plug for any signs of damage or wear. Ensure the weatherproof cover is intact and seals properly.
- Storage: If storing the timer for an extended period, ensure it is clean and dry. Store in a cool, dry place away from direct sunlight.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Timer display is blank. | No power to the unit. | Check if the timer is properly plugged into a live outlet. Verify the outlet has power. |
| Appliances do not turn ON/OFF as programmed. |
|
|
| Random function not working. | Random function not activated. | Activate the random function using the MODE button (Section 5.2). |
| Unit feels warm. | Overload or normal operation. | Ensure total wattage of connected devices does not exceed 1875W. Slight warmth during operation is normal. If excessively hot, disconnect immediately. |
8. Specifications
- Model: B0FPXF5RYK
- Input Voltage: 125 Volts AC
- Max Current: 15 Amps
- Max Power: 1875 Watts Resistive
- Motor Rating: 1/3 HP
- Outlets: 3 Grounded Outlets
- Cord Type: 6-inch SJTW 14-3 Grounded Cord
- Material: Heavy duty PPE+PS
- Programming: Up to 20 ON/OFF settings, weekly repeat.
- Display: 24-hour system (military time).
- Special Features: Weatherproof, Random Function.
9. Warranty and Support