1. Introduction
Thank you for purchasing the ASGYISA 6-Light Semi Flush Mount Ceiling Light Fixture. This fixture is designed to provide ambient lighting with a modern aesthetic. Please read this manual thoroughly before installation and use to ensure safe operation and optimal performance. Keep these instructions for future reference.
2. Safety Information
- WARNING: Risk of electric shock. Disconnect power at the fuse box or circuit breaker before installing or servicing.
- All electrical connections must be in accordance with local codes, ordinances, or the National Electric Code (NEC). Contact a qualified electrician if you are unfamiliar with proper electrical wiring connections.
- Use only E26 base bulbs, maximum 60 watts per socket. Do not exceed the recommended wattage.
- Ensure the fixture is securely mounted to a structural part of the ceiling.
- Do not handle the light fixture or bulbs with wet hands.
- Allow bulbs to cool before replacing them.
3. Package Contents
Verify that all parts are included before beginning installation:
- Mounting Bracket
- Canopy
- Fixture Arms (6 pieces)
- Socket Holders (6 pieces, pre-attached to arms)
- Mounting Screws and Wire Nuts
- Ground Wire
Note: E26 bulbs are not included and must be purchased separately.
4. Setup and Installation
Follow these steps for proper installation of your ceiling light fixture.
4.1 Assembly of Fixture Arms
- Carefully unpack all components and lay them out on a clean, flat surface.
- Attach each fixture arm to the central canopy. Ensure the wires from each arm are fed through the designated holes in the canopy.
- Secure each arm using the provided nuts and washers. Tighten firmly with a wrench.
- Connect the corresponding wires from each arm to the main wires within the canopy. Typically, white wires connect to white, and black wires connect to black. Ensure all connections are secure with wire nuts.
Visual Aid: Fixture Dimensions and Bulb Compatibility

Image: Fixture dimensions and compatible E26 bulb types.
Visual Aid: Component Details

Image: Detailed view of the fixture's matte black iron, E26 light source, sturdy metal, and universal lamp head.
4.2 Ceiling Mounting
- IMPORTANT: Turn off power at the circuit breaker before proceeding.
- Attach the mounting bracket to the junction box in your ceiling using the provided screws.
- Connect the fixture's ground wire to the ground wire from the junction box (usually bare copper or green).
- Connect the fixture's white wire to the white (neutral) wire from the junction box.
- Connect the fixture's black wire to the black (live) wire from the junction box.
- Carefully tuck all wires into the junction box.
- Align the canopy with the mounting bracket and secure it with the decorative nuts.
4.3 Bulb Installation
- Screw E26 base bulbs (not included) into each socket. Do not overtighten.
- Ensure bulbs are rated for E26 base and do not exceed 60 watts per bulb.
Installation Video:
Video: Step-by-step installation guide for the ASGYISA 6-Light Semi Flush Mount Ceiling Light.
5. Operating Instructions
Once installed, operate the light fixture using your standard wall switch. This fixture is compatible with dimmable bulbs and dimmer switches (sold separately) for adjustable light intensity.
Visual Aid: Light On/Off States and Bulb Compatibility

Image: Demonstrates the light fixture with bulbs off and on, and illustrates compatible E26 bulb types.
6. Maintenance
6.1 Cleaning
- Always turn off the power before cleaning.
- Wipe the fixture with a soft, dry cloth.
- Do not use abrasive cleaners, solvents, or polishes as they may damage the finish.
6.2 Bulb Replacement
- Ensure the power is off and the bulbs have cooled completely before attempting to replace them.
- Carefully unscrew the old bulb and screw in a new E26 base bulb, ensuring it does not exceed 60 watts.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on | 1. Power is off 2. Loose wiring connection 3. Faulty bulb | 1. Check circuit breaker/wall switch 2. Verify all wire connections are secure (power off first) 3. Replace bulb |
| Light flickers | 1. Loose bulb 2. Incompatible dimmer switch 3. Loose wiring | 1. Tighten bulb 2. Ensure dimmer is compatible with LED/incandescent bulbs 3. Check wiring connections (power off first) |
| Bulbs burn out quickly | 1. Incorrect wattage 2. Poor quality bulbs | 1. Use bulbs within the 60W limit 2. Try a different brand of bulbs |
8. Specifications
- Brand: ASGYISA
- Model Name: L-1460
- Material: Iron
- Color: Black
- Style: Modern
- Light Fixture Form: Close to Ceiling
- Product Dimensions: Approximately 22.44"L x 22.44"W x 4.33"H (based on image)
- Number of Light Sources: 6
- Bulb Base: E26
- Max Wattage per Bulb: 60 watts
- Voltage: 110 Volts
- Finish Type: Matte
- Mounting Type: Ceiling Mount
- Indoor/Outdoor Usage: Indoor
- Item Weight: 3.3 pounds
9. Warranty and Support
This product comes with a limited warranty. For any questions, issues, or support needs regarding installation or operation, please contact ASGYISA customer service. We are committed to providing a satisfactory experience for every customer.
Please refer to your purchase documentation for specific warranty details and contact information.