1. Introduction
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your VEVOR Linear Air Pump LP60. This pump is designed for various aeration needs, including fish ponds, septic tanks, hydroponic systems, and aquariums, providing efficient oxygen supply and promoting water circulation.
The LP60 model features a maximum flow rate of 1110 GPH (70 LPM), a maximum air pressure of 5.36 PSI, and is suitable for water depths up to 10 feet (3.05 meters). It is engineered for quiet operation and durability with an aluminum alloy housing and IP44 waterproof rating.

Image 1.1: VEVOR Linear Air Pump LP60 highlighting its powerful airflow aeration capabilities.
2. Safety Instructions
- Read all instructions carefully before operating the pump.
- Ensure the power supply matches the pump's specifications (AC 120V 60Hz).
- Do not operate the pump with a damaged power cord or plug.
- Keep the pump away from flammable materials and extreme temperatures.
- Ensure proper ventilation around the pump to prevent overheating.
- Do not immerse the pump in water. It has an IP44 waterproof rating, meaning it is protected against splashing water, but not submersion.
- Always disconnect the power supply before performing any maintenance or cleaning.
- Keep children and pets away from the operating pump.
- Inspect the pump regularly for any signs of damage or wear.

Image 2.1: The VEVOR Linear Air Pump LP60 is built with a durable aluminum alloy housing and IP44 rating for outdoor use.
3. Package Contents
Verify that all items are present in the package:
- 1 x VEVOR Linear Air Pump LP60
- 1 x Air Diffuser (14-outlet)
- 1 x Black Connecting Hose
- 2 x Clamps
- 2 x Diaphragms (replacement parts)
- 1 x User Manual (this document)
Note: Air tubes and air stones are not included and must be purchased separately.

Image 3.1: VEVOR Linear Air Pump LP60 and its included accessories.
4. Setup and Installation
Follow these steps for proper installation of your VEVOR Linear Air Pump LP60:
- Placement: Place the air pump on a stable, level surface in a well-ventilated area. Ensure it is protected from direct sunlight and heavy rain, despite its IP44 rating.
- Connect Air Diffuser: Connect the black connecting hose to the air diffuser.
- Attach to Pump: Attach the assembled air diffuser and hose to the pump's air outlet.
- Secure Connections: Use the provided clamps to secure the connections, ensuring no air leaks.
- Connect Airline Tubes (Not Included): If using, connect your own airline tubes to the air diffuser outlets.
- Connect Air Stones (Not Included): Attach air stones to the ends of the airline tubes for optimal bubble diffusion in water.
- Power Connection: Plug the pump into a standard AC 120V 60Hz electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) if used near water.

Image 4.1: Step-by-step guide for connecting the air diffuser and hose to the pump.
5. Operating Instructions
Once properly installed and connected to power, the VEVOR Linear Air Pump LP60 will begin operating. It is designed for continuous operation to provide consistent aeration.
- Initial Start-up: After plugging in, the pump will immediately start producing airflow. Verify that air is flowing through the diffuser and into your application (pond, tank, etc.).
- Monitoring: Periodically check the airflow to ensure optimal performance. The pump operates quietly (below 47 dBA), so listen for any unusual noises that might indicate an issue.
- Application Depth: The pump is effective for depths up to 10 feet (3.05 meters). Ensure your application's depth is within this range for efficient aeration.

Image 5.1: The VEVOR Linear Air Pump LP60 operates with low noise, suitable for long-term use without disturbance.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your air pump.
- Air Filter Cleaning: The pump has a built-in inlet filter cotton to reduce noise and dust. Periodically inspect and clean this filter. Disconnect power before accessing the filter. Clean with compressed air or rinse with water and ensure it is completely dry before reinstallation.
- Diaphragm Replacement: The diaphragms are wear-and-tear components. If you notice a significant drop in airflow or increased noise, the diaphragms may need replacement. Your package includes two spare diaphragms. Refer to the pump's internal structure diagram (if available in a more detailed manual) for replacement instructions, or contact VEVOR support.
- Housing Inspection: Regularly check the aluminum alloy housing for any cracks or damage. Ensure all rubber feet and shock absorbers are intact to maintain quiet operation.
- General Cleaning: Keep the exterior of the pump clean and free from debris. Do not use harsh chemicals for cleaning.

Image 6.1: Internal components and features designed for quiet and efficient operation, requiring occasional inspection.
7. Troubleshooting
If you encounter issues with your VEVOR Linear Air Pump LP60, refer to the following table for common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Pump does not start or no airflow. |
|
|
| Low or weak airflow. |
|
|
| Excessive noise or vibration. |
|
|
| Pump overheating. |
|
|
8. Specifications
| Feature | Specification |
|---|---|
| Item Model Number | LP60 |
| Voltage | AC 120V 60Hz |
| Power | 50W |
| Maximum Flow Rate | 1110 GPH / 70 LPM |
| Air Pressure | 5.36 PSI / 0.037 MPa |
| Waterproof Rating | IP44 |
| Product Dimensions (L x W x H) | 10.04 x 7.87 x 8.27 in / 255 x 200 x 210 mm |
| Net Weight | 11.68 lbs / 5.3 kg |
| Operating Noise | ≤ 47 dBA |
| Filtration Method | Built-in Air Filter |
| Material | Aluminum alloy housing |
| Applicable Depth | ≤ 10 ft / 3.05 m |
9. Warranty and Support
For warranty information, please refer to the warranty card included with your product or visit the official VEVOR website. Keep your purchase receipt as proof of purchase.
If you require technical assistance, have questions about operation, or need to order replacement parts, please contact VEVOR customer service. Contact details can typically be found on the VEVOR website or on the product packaging.