Walfront gorbps0a1e

WALFRONT 0-10V Adjustable Signal Generator Instruction Manual

Model: gorbps0a1e

1. Introduction

This manual provides instructions for the safe and effective operation of the WALFRONT 0-10V Adjustable Signal Generator. This device is designed to provide a stable 0-10V voltage signal output for various industrial and testing applications.

2. Product Features

  • 0-10V Analog Output: Features one analog output channel capable of generating a 0-10V voltage signal.
  • Display Calibration: Equipped with potentiometers on the back for precise voltage display calibration.
  • Robust Protection: Includes overcurrent protection, reverse connection protection, and a protective back cover to resist dusty environments.
  • Clear Display: A 4-digit digital tube display with high brightness, offering three switchable display modes: Voltage, Percentage, and Hz.
  • Adjustable Output: A rotation encoder allows for fine and coarse tuning of the output signal.
  • Easy Wiring: Designed with large terminals for straightforward and secure connections.

3. Specifications

ParameterValue
Modelgorbps0a1e
Power Supply15-30V DC
Output Channel1 Analog Output (0-10V)
Display Accuracy0.01V
Operation Accuracy0.01V
Maximum Load Current0.2A
Display Type4-Digit Digital Tube Display
Encoder Pulses per Turn20 Pulses
Operating Temperature-10°C to 60°C
Dimensions3.54 x 2.36 x 1.97 inches (approx.)
Weight2.12 ounces (approx.)

4. Setup and Wiring

Before connecting the signal generator, ensure the power supply is off. Connect the device according to the wiring diagram below. The large terminals facilitate easy and secure connections.

Wiring schematic diagram for Walfront 0-10V Signal Generator

Figure 4.1: Wiring schematic diagram for connecting the signal generator to voltage signal acquisition equipment. Connect V+ and V- to the 24V power supply, and OUT+ and OUT- to AV+ and AV- of the acquisition equipment, respectively.

Power Supply: The device requires a 15-30V DC power supply. Ensure correct polarity as the device includes anti-reverse connection protection.

Output Connection: Connect the output terminals (OUT+ and OUT-) to your target device or system that requires a 0-10V analog input.

5. Operating Instructions

Once properly wired and powered on, the signal generator's 4-digit digital tube display will illuminate.

5.1 Adjusting Output Voltage

Close-up of the Walfront 0-10V Signal Generator display and rotary encoder

Figure 5.1: Front view of the signal generator showing the digital display and the rotary encoder for output adjustment.

  • Rotary Encoder: Use the rotary encoder knob on the front panel to adjust the output voltage. Turning the knob clockwise increases the voltage, and counter-clockwise decreases it.
  • Coarse and Fine Tuning: The encoder provides both coarse and fine tuning capabilities. A single turn of the encoder corresponds to 20 pulses, allowing for precise adjustments.
  • Saving Output Value: Press the rotary encoder knob to save the current output value. This ensures the device retains the setting even after power cycling.

5.2 Display Modes

The digital display can switch between three modes:

  • Voltage (V): Displays the current output voltage in Volts.
  • Percentage (%): Displays the output as a percentage of the full 10V scale.
  • Frequency (Hz): (Note: While the product title mentions "Frequency Control Meter", the specifications and description primarily focus on voltage output. This mode might display a related frequency if applicable, or it might be a general display option for other models. For this 0-10V model, the voltage and percentage modes are most relevant.)

Refer to the device's specific button or knob press sequence (if any, not detailed in provided info) to cycle through these display modes.

5.3 Display Calibration

Walfront 0-10V Signal Generator connected to a multimeter displaying 10.00V

Figure 5.2: The signal generator's output being measured by a multimeter, showing a stable 10.00V reading, demonstrating accuracy.

If the displayed voltage value deviates from the actual output, you can calibrate it:

  1. Connect a precise voltmeter or multimeter to the output terminals (OUT+ and OUT-).
  2. Locate the voltage display calibration potentiometers on the back of the module.
  3. Adjust these potentiometers carefully until the value displayed on the signal generator matches the reading on your external voltmeter.

6. Applications

The WALFRONT 0-10V Adjustable Signal Generator is suitable for a variety of industrial and testing scenarios:

Collage of various industrial applications including valve regulation, PLC debugging, and LED testing, with the Walfront signal generator in the foreground

Figure 6.1: Examples of the signal generator's diverse applications in industrial settings.

  • Valve Regulation: For controlling industrial valves that accept 0-10V input.
  • Frequency Control: (If used in conjunction with devices that convert voltage to frequency.)
  • PLC Debugging: Providing precise analog signals for testing and debugging Programmable Logic Controllers.
  • Panel Debugging: Assisting in the setup and troubleshooting of control panels.
  • LED Testing: Supplying controlled voltage for testing LED drivers or arrays.
  • Analog Transmitter Output Simulation: Simulating outputs from various analog transmitters.

7. Maintenance

The WALFRONT Signal Generator is designed for durability and requires minimal maintenance.

  • Cleaning: Keep the device clean and free from dust. Use a soft, dry cloth for cleaning. Avoid liquid cleaners.
  • Environment: Operate the device within the specified temperature range (-10°C to 60°C). The protective back cover helps resist dusty environments.
  • Storage: Store the device in a cool, dry place when not in use.
  • Inspection: Periodically inspect wiring connections for security and integrity.

8. Troubleshooting

ProblemPossible CauseSolution
No display/No powerIncorrect power supply voltage or polarity; loose power connection.Verify power supply is 15-30V DC and connected with correct polarity. Check all power connections.
Incorrect output voltageDisplay calibration needed; faulty wiring to target device; target device input impedance issue.Perform display calibration (Section 5.3). Check output wiring. Ensure target device is compatible with 0-10V input.
Output voltage unstableUnstable power supply; excessive load current.Ensure power supply is stable. Verify load current does not exceed 0.2A.
Display shows unexpected values (e.g., "Hz" when expecting "V")Incorrect display mode selected.Cycle through display modes using the appropriate control (refer to device specific operation if available).

9. Package Contents

  • 1 x WALFRONT 0-10V Adjustable Signal Generator

10. Warranty and Support

For warranty information and technical support, please refer to the retailer or manufacturer's official website. Keep your purchase receipt for warranty claims.

Manufacturer: WALFRONT

ASIN: B0FP9PYVKQ

Date First Available: August 30, 2025

For further assistance, please visit the Walfront Store on Amazon.

Related Documents - gorbps0a1e

Preview 部品/規格/技術ノート - 農業向けアクティブ・デバイス
Interface誌掲載の部品/規格/技術ノート。農業における害獣・人検出センサー(焦電、ドップラー、超音波)やアクティブ・デバイスに関する技術情報と製品仕様を解説。