GRYVOZE B313

GRYVOZE Mechanical Oil Control Valve Flow Meter Dispenser Nozzle (Model B313) User Manual

Model: B313 | Brand: GRYVOZE

1. Introduction

The GRYVOZE Mechanical Oil Control Valve Flow Meter Dispenser Nozzle, Model B313, is designed for precise and efficient dispensing of various oils in industrial and automotive settings. This robust, fully mechanical device provides accurate flow measurement without the need for batteries or complex calibration, ensuring reliable performance in demanding environments. It is suitable for both light and heavy-duty applications, offering ease of use and durability.

GRYVOZE Mechanical Oil Control Valve Flow Meter Dispenser Nozzle in use, showing effortless operation

Image: The GRYVOZE B313 dispenser nozzle in operation, demonstrating its straightforward and maintenance-free design.

2. Safety Information

Please read and understand all safety instructions before operating the GRYVOZE B313 dispenser nozzle. Failure to follow these instructions may result in injury or damage to the equipment.

  • Always wear appropriate personal protective equipment (PPE), including safety glasses and gloves, when handling oils and operating the dispenser.
  • Ensure the work area is well-ventilated and free from ignition sources, as some oils may be flammable.
  • Do not exceed the maximum working pressure of 1500 PSI (100 bar).
  • Operate the dispenser within the specified temperature range of -10 °C to +50 °C (14 °F to 122 °F).
  • Keep the dispenser clean and free from debris to prevent malfunctions.
  • Ensure all connections are secure before operation to prevent leaks.

Important: This dispenser is NOT FOR USE with Gasoline, Water, Alcohol, or Corrosive Chemicals. Use only with compatible medium- to high-viscosity oils as specified.

Diagram showing compatible oil types and incompatible liquids for the dispenser nozzle

Image: Visual guide indicating suitable oil types (Engine Oil, Transmission Oil, Gear Oil, Hydraulic Oil) and unsuitable liquids (Gasoline, Water, Alcohol, Chemical).

3. Product Features

The GRYVOZE B313 dispenser nozzle incorporates several features designed for performance and user convenience:

  • Mechanical Flow Meter: Measures oil flow from 0.26–9.25 GPM with ±0.5% accuracy. No batteries, setup, or calibration required.
  • Durable Construction: Fully mechanical design, waterproof, dustproof, and temperature-resistant for harsh industrial environments. Constructed from aerospace-grade aluminum for corrosion, wear, and oxidation resistance.
  • Precise Measurement Display: Features a clear, easy-to-read dial displaying both total and resettable batch quantities in quarts.
  • Automatic Shutoff Tip: Anti-drip design prevents leaks from the outlet, ensuring clean and precise dispensing.
  • Flexible Hose & 90° Outlet: The flexible rubber hose allows access to tight areas, and the 90° motor oil gun outlet facilitates smoother refueling.
  • Ergonomic Design: Comfortable handle with a locking trigger for controlled, hands-free operation.
  • 360° Swivel Inlet: Allows for easier hose connection and reduced leakage.
  • Built-in Filter: Integrated filter ensures smoother flow and prevents impurities from entering the system.
Image illustrating the durable mechanical design of the oil dispenser, highlighting its waterproof, dustproof, and shockproof qualities

Image: The robust construction of the GRYVOZE B313, designed to withstand challenging conditions.

Close-up of the high-accuracy oil measurement dial on the dispenser, showing total and batch quantity displays

Image: Detailed view of the mechanical flow meter, showing the easy-to-read dial for total and batch measurements.

Diagram highlighting the ergonomic handle, locking trigger, and 360-degree swivel inlet of the oil dispenser

Image: Key ergonomic and design features, including the comfortable grip, locking trigger, and swivel inlet.

4. Package Contents

Verify that all items are present in the package:

  • 1 x GRYVOZE Mechanical Oil Control Gun with Meter
  • 1 x User Manual
GRYVOZE Mechanical Oil Control Valve Flow Meter Dispenser Nozzle and included user manual

Image: The GRYVOZE B313 dispenser nozzle and its accompanying user manual.

5. Setup

Follow these steps to set up your GRYVOZE B313 dispenser nozzle:

  1. Inspect the Unit: Before first use, visually inspect the dispenser for any signs of damage from shipping. Ensure all components are securely attached.
  2. Connect to Hose: Attach the 1/2" NPT inlet of the dispenser nozzle to your oil supply hose. Ensure the connection is tight and secure to prevent leaks. The 360° swivel inlet allows for flexible positioning.
  3. Verify Compatibility: Confirm that the oil to be dispensed is compatible with the unit (medium- to high-viscosity oils only). Refer to the Safety Information section for incompatible liquids.
  4. Initial Flow Check: Before dispensing into a target container, perform a brief test flow into a waste container to ensure proper operation and to prime the system.

6. Operating Instructions

Operating the GRYVOZE B313 dispenser nozzle is straightforward:

  1. Position the Nozzle: Place the flexible rubber hose and 90° outlet into the fill opening of the target container or engine. The flexible design allows access to tight or hard-to-reach areas.
  2. Dispense Oil: Squeeze the trigger handle to begin dispensing oil. The flow meter will immediately start measuring the dispensed quantity.
  3. Use Locking Trigger (Optional): For continuous dispensing, engage the locking trigger mechanism. To disengage, simply squeeze the trigger again.
  4. Monitor Measurement: Observe the clear dial on the flow meter. The top display shows the total accumulated quantity, while the bottom display shows the current batch quantity. Measurements are in U.S. Quarts.
  5. Stop Dispensing: Release the trigger to stop the flow. The automatic shutoff tip will prevent drips.
  6. Reset Batch Counter: After each dispensing operation, press the mechanical reset button on the flow meter to clear the batch quantity for the next measurement. The total quantity will continue to accumulate.
Person using the GRYVOZE oil dispenser nozzle to add oil to an engine

Image: The GRYVOZE B313 in action, demonstrating oil dispensing into an automotive engine.

7. Maintenance

Regular maintenance ensures the longevity and accuracy of your GRYVOZE B313 dispenser nozzle.

7.1 General Cleaning

  • After each use, wipe down the exterior of the dispenser with a clean cloth to remove any oil residue.
  • Periodically check the inlet filter for any accumulated debris and clean if necessary.

7.2 Flow Chamber Disassembly & Cleaning

If the flow meter's accuracy is compromised or flow is restricted, the internal flow chamber may require cleaning. Follow these steps:

  1. Remove Protective Cover: Carefully remove the rubber protective cover from the flow meter.
  2. Unscrew Screws: Unscrew the four screws located at the bottom of the flow meter housing.
  3. Lift Top Cover: Gently lift off the top cover of the flow meter.
  4. Remove Oval Gears: Carefully take out the oval gears from the chamber. Note their orientation for reassembly.
  5. Clean Chamber: Clean the flow chamber and passages with a soft brush or cloth. Use a suitable cleaning agent if necessary, ensuring it is compatible with aluminum and rubber components.
  6. Reassemble: Reassemble all parts in reverse order, ensuring the oval gears are correctly positioned and the screws are firmly secured.
Step-by-step guide for disassembling and cleaning the flow chamber of the oil dispenser

Image: Visual instructions for disassembling and cleaning the flow meter's internal components.

8. Troubleshooting

If you encounter issues with your GRYVOZE B313 dispenser nozzle, refer to the following common problems and solutions:

ProblemPossible CauseSolution
No oil flow or restricted flowClogged inlet filter; Blockage in nozzle or hose; Insufficient oil supply pressure.Check and clean the inlet filter. Inspect nozzle and hose for blockages. Ensure adequate oil supply pressure.
Inaccurate flow meter readingsDebris in flow chamber; Incorrect oil viscosity; Air in the system.Clean the flow chamber (refer to Maintenance section). Ensure oil viscosity is within specified range. Bleed air from the system if present.
Oil leakage from connectionsLoose connections; Damaged seals/O-rings.Tighten all connections. Inspect and replace any damaged seals or O-rings.
Batch counter not resettingMechanical reset button stuck or damaged.Ensure the reset button is not obstructed. If damaged, contact customer support.

If the problem persists after attempting these solutions, please contact GRYVOZE customer support for further assistance.

9. Specifications

Detailed technical specifications for the GRYVOZE B313 Mechanical Oil Control Valve Flow Meter Dispenser Nozzle:

SpecificationValue
Model NumberB313
BrandGRYVOZE
MaterialAluminum
Item Dimensions (L x W x H)22.84 x 3.74 x 7.87 inches
Item Weight4.26 Pounds
Inlet Connection Size1/2 Inch
Inlet Connection TypeNational Pipe Tapered (NPT)
Outlet Connection Size0.5 Inches
Outlet Connection TypeNPT
Maximum Operating Pressure1500 PSI / 100 bar
Flow Rate Range0.26–9.25 GPM (1–35 LPM)
Accuracy±0.5%
Working Temperature-10 °C to +50 °C (14 °F to 122 °F)
Applicable Oil Viscosity8–5000 mPa·s
Number of Ports2
Valve TypeGlobe Valve
UPC850072214306

10. Warranty and Support

For warranty information, technical support, or service inquiries regarding your GRYVOZE B313 Mechanical Oil Control Valve Flow Meter Dispenser Nozzle, please contact GRYVOZE customer support directly. Refer to the product packaging or the official GRYVOZE website for contact details.

Please retain your purchase receipt as proof of purchase for any warranty claims.

© 2025 GRYVOZE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.