Anjfylque ANJ-12KP-48V-WIFI

Download PDF
Contents

Anjfylque ANJ-12KP-48V-WIFI 12000W Hybrid Solar Inverter User Manual

Model: ANJ-12KP-48V-WIFI

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Anjfylque ANJ-12KP-48V-WIFI 12000W Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure proper use and safety. This inverter is designed for off-grid home and business use, converting DC power to 120V/240V split-phase or 120V single-phase AC power.

2. Safety Instructions

Important Safety Information:

  • Installation must be performed by qualified personnel.
  • Ensure all power sources are disconnected before installation or maintenance.
  • Do not operate the inverter if it is damaged or appears to be malfunctioning.
  • Avoid contact with live terminals.
  • Ensure proper grounding of the unit.
  • Do not expose the inverter to rain, snow, or liquids.
  • Maintain adequate ventilation around the inverter to prevent overheating.
  • Refer to local electrical codes and regulations for all wiring and installation procedures.

3. What's in the Box

Upon unpacking, please verify that all items are present and undamaged:

  • The Anjfylque ANJ-12KP-48V-WIFI Inverter Unit x 1
  • Parallel Communication Line x 1 (as shown in unboxing video)
  • Quality Inspection Label x 1
  • Bolts and Copper Noses (for wiring connections)
  • Installation Guide x 1
  • Warranty Card x 1
Anjfylque ANJ-12KP-48V-WIFI Inverter and accessories

Image: Contents of the Anjfylque ANJ-12KP-48V-WIFI inverter package, including the inverter unit, cables, and documentation.

Video: Unboxing the Anjfylque 12KW Hybrid Solar Inverter, showing the packaging and included components.

4. Setup & Installation

4.1 Preliminary Preparation

Before beginning installation, ensure you have the following items and tools:

  • Two 4P 63A AC circuit breakers
  • One 2P 250A DC circuit breaker
  • Three 2P 32A DC circuit breakers
  • Two copper bars that can withstand 600A
  • Five 4AWG wires (yellow, red, green, blue, yellow, and green)
  • Eight 250 kcmil battery cables
  • Six 10 AWG wires
  • Phillips screwdriver, Ratchet turning screwdriver, Handle sleeve (13mm, 10mm)

Inspect the equipment for any damage and ensure all terminals are free of rust.

4.2 Line Connection Order

Always follow the strict wiring order: Battery → Mains → Load → Photovoltaic for all wiring operations.

4.3 Battery Wiring

  1. Connect the battery wire to the DC circuit breaker.
  2. Ensure the battery circuit breaker is disconnected before proceeding.
  3. Connect all positive battery poles to one copper bar and all negative poles to another copper bar. Ensure firm connections to avoid false or missing connections.
  4. Check that the insulation layer of all wires is intact to prevent short circuits.
  5. Connect the battery wires from the copper bars to the inverter's BAT+ and BAT- terminals. Pay close attention to polarity (Red for positive, Black for negative).
Anjfylque ANJ-12KP-48V-WIFI Inverter rear panel with connection points

Image: Rear panel of the Anjfylque inverter showing AC IN, AC OUT, USB, WiFi, RS485/CAN, Dry Contact, Parallel Connection, Battery, and PV interfaces.

4.4 AC Input Connection (Mains)

When connecting to alternating current, it is necessary to use a combiner box for convenient wiring. The combiner box should have 5 copper bars capable of handling 200A, each with at least 4 holes.

  1. Connect the A phase, B phase, C phase, and N line of the mains to the 4P 63A AC circuit breaker.
  2. Connect the end of these wires with copper noses to the combiner box.
  3. For the first inverter (Master, A phase): Connect L1 of the inverter to phase A, and connect the N line and PE line in sequence.
  4. For the second inverter (Slave 1, B phase): Connect L1 of the inverter to phase B, and connect the N line and PE line in sequence.
  5. For the third inverter (Slave 2, C phase): Connect L1 of the inverter to phase C, and connect the N line and PE line in sequence.
  6. Repeat the process for AC OUT connections, ensuring correct phase alignment.

Video: Detailed parallel wiring guide for the Anjfylque 12KW split-phase off-grid inverter, demonstrating connections for multiple units.

Inverter System Configuration diagram

Image: Detailed inverter system configuration showing input voltage range, rated output, battery voltage range, and various connections.

5. Operation

5.1 Initial Parameter Settings (for Parallel Operation)

After all physical connections are made, proceed with the initial parameter settings on the inverter's capacitive touch screen:

  1. Close the battery circuit breaker.
  2. Start the system equipment one by one through the rocker switch.
  3. Enter the equipment control interface.
  4. Set the master-slave role and phase parameter configuration:
    • Master (A phase): Set the first inverter as "Three-phase master" and "A Phase".
    • Slave 1 (B phase): Set the second inverter as "Slave" and "B Phase".
    • Slave 2 (C phase): Set the third inverter as "Slave" and "C Phase".
  5. After confirming the parameters are correct, turn off the power of all equipment.
  6. Wait for the subsequent startup operation.
  7. Connect the parallel communication cables between the inverters.
Anjfylque ANJ-12KP-48V-WIFI Inverter display showing system status

Image: Inverter display showing real-time data on solar production, battery status, grid power, and consumption.

Anjfylque ANJ-12KP-48V-WIFI Inverter smart app control interface

Image: Smart app control interface for the Anjfylque inverter, showing real-time monitoring, power consumption statistics, fault warnings, and data analysis.

5.2 System Startup and Operation

To start the system after initial setup and parameter configuration:

  1. Close the battery circuit breaker.
  2. Close the photovoltaic circuit breaker.
  3. Close the mains circuit breaker.
  4. Close the load circuit breaker.
  5. Start all inverter units simultaneously by turning on their rocker switches.

Ensure that the system is put into operation smoothly. Monitor the display for any fault messages.

Anjfylque ANJ-12KP-48V-WIFI Inverter showing multiple units in parallel

Image: Multiple Anjfylque inverters connected in parallel, demonstrating expanded power capacity.

6. Maintenance

Regular maintenance ensures optimal performance and longevity of your inverter:

  • Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust buildup. Use a dry, soft cloth. Do not use liquid cleaners.
  • Connections: Annually check all electrical connections for tightness and signs of corrosion. Tighten any loose connections.
  • Ventilation: Ensure the inverter's cooling system is unobstructed. The intelligent cooling system only activates when needed, ensuring efficient cooling with minimal disturbance.
  • Battery Health: Monitor battery voltage and charge levels regularly. Refer to your battery manufacturer's guidelines for specific maintenance.
  • Firmware Updates: Check the manufacturer's website or mobile app for any available firmware updates to ensure optimal performance and security.
Anjfylque ANJ-12KP-48V-WIFI Inverter with low noise and intelligent cooling features

Image: Anjfylque inverter highlighting its low-noise operation and intelligent cooling system, designed for indoor comfort.

7. Troubleshooting

This section provides guidance for common issues. For complex problems, contact Anjfylque customer support.

ProblemPossible CauseSolution
Inverter not turning onNo battery power, loose connections, faulty switch.Check battery voltage, ensure all connections are secure, verify rocker switch position.
"Parallel mode setting error" on displayIncorrect master/slave configuration or phase settings.Re-enter system settings and verify master/slave and phase assignments as per Section 5.1.
Low power outputInsufficient PV input, battery degradation, overloaded system.Check PV array performance, inspect battery health, reduce load or add more inverters/batteries.
OverheatingBlocked ventilation, excessive ambient temperature, overloaded.Clear obstructions from vents, ensure proper airflow, reduce load.

8. Specifications

FeatureDetail
ModelANJ-12KP-48V-WIFI
Rated Power12000W
Output Voltage120V/240V Split-Phase or 120V Single-Phase
MPPT Charge ControllersDual 80A MPPTs
Max PV Array Power18,000W (9,000W + 9,000W)
MPPT Voltage Range125–425V DC
Max Solar Charging Current220A
Max AC Charging Current140A
Parallel SupportUp to 6 units
Battery CompatibilityLithium-ion, Lead-acid, User-customized (BMS communication)
Communication InterfacesBluetooth, Wi-Fi, RS485/CAN
Protection FeaturesPV overvoltage, battery overcurrent/undervoltage, AC short-circuit, overtemperature, anti-reverse flow
Enclosure RatingIP54
Product Dimensions12 x 13 x 4.5 inches
Item Weight33 pounds

9. Warranty & Support

The Anjfylque ANJ-12KP-48V-WIFI Hybrid Solar Inverter comes with a three-year warranty from the date of purchase. Please retain your proof of purchase and the warranty card included in the package.

For technical support, troubleshooting assistance, or warranty claims, please contact Anjfylque customer service through the contact information provided on your warranty card or the official Anjfylque website.

Online Resources:

  • Mobile App: Supports remote monitoring and control via mobile app and cloud platform. Search for "EnerWise" app on your app store.
  • Official Website: Visit the Anjfylque website for FAQs, updated manuals, and support.

© 2025 Anjfylque. All rights reserved. Information in this manual is subject to change without notice.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.