HAKINAKU HD11

HAKINAKU HD11 5-in-1 Smoke, Carbon Monoxide, and Combustible Gas Detector User Manual

Model: HD11

1. Introduction

This manual provides essential information for the proper installation, operation, and maintenance of your HAKINAKU HD11 5-in-1 Detector. This device is designed to monitor for carbon monoxide (CO), smoke, and combustible gases, while also displaying temperature and humidity levels. Please read this manual thoroughly before using the product to ensure safe and effective operation.

2. Safety Information

WARNING: This device is not a substitute for proper fire safety practices or professional gas leak detection equipment. It is intended to provide early warning of potential hazards.

  • Do not paint the detector. Paint can clog the sensing vents and interfere with the unit's ability to detect CO, smoke, or gas.
  • Do not block the vents on the detector. Ensure proper airflow for accurate readings.
  • Do not install in areas with extreme temperatures or humidity, as this can affect performance.
  • Regularly test the detector as instructed in this manual.
  • In case of an alarm, follow emergency procedures immediately.

3. Product Overview

The HAKINAKU HD11 is a versatile 5-in-1 detector designed for comprehensive environmental monitoring. It integrates sensors for carbon monoxide, smoke, and combustible gases, alongside temperature and humidity displays. The device features a plug-in design with a built-in backup battery for continuous operation during power outages.

Key Features:

  • 5-in-1 Detection: Monitors Carbon Monoxide (CO), Smoke, Combustible Gas (e.g., natural gas, propane, methane), Temperature, and Humidity.
  • Plug-in Design: Compatible with standard 110V-220V AC outlets.
  • Backup Battery: Built-in 2000mAh rechargeable lithium battery provides approximately 18-20 hours of operation during power interruptions.
  • HD Screen Display: A 2.1-inch high-definition screen dynamically shows real-time data including CO ppm, smoke indication bar, combustible gas warning icon, humidity, and temperature.
  • Audible and Visual Alarms: Features an 85 dB alarm and visual indicators for detected hazards.

Components:

  • HAKINAKU HD11 Detector Unit
  • User Manual (this document)
Two HAKINAKU HD11 5-in-1 detectors plugged into wall outlets, displaying CO, Gas, Smoke, Temperature, and Humidity readings on their screens.

Image: Front view of two HAKINAKU HD11 detectors, showcasing their digital displays and compact design when plugged into a wall outlet.

HAKINAKU HD11 detector unit detached from its plug-in base, highlighting its compact size and the separate plug component.

Image: The HAKINAKU HD11 detector unit shown alongside its detachable plug-in base, illustrating the two main components of the device.

4. Setup

4.1 Unboxing

Carefully remove the detector unit and any included accessories from the packaging. Inspect the device for any visible damage. If damage is found, do not proceed with installation and contact customer support.

4.2 Placement Recommendations

For optimal performance and safety, consider the following placement guidelines:

  • Carbon Monoxide (CO) Detection: Install at least 5 feet (1.5 meters) from fuel-burning appliances to avoid false alarms from their normal operation. Place at knee level or higher, but not on the ceiling, as CO mixes with air.
  • Smoke Detection: Install on a wall or ceiling. For wall mounting, the top of the detector should be 4 to 12 inches (10 to 30 cm) from the ceiling. Avoid placing near windows, doors, or air vents where drafts could interfere with smoke reaching the sensor.
  • Combustible Gas Detection: Since many combustible gases (like natural gas) are lighter than air, install the detector higher up on a wall, near the ceiling. For heavier-than-air gases (like propane), install closer to the floor. If monitoring both, a mid-level placement may be necessary, or consider multiple units.
  • General Placement: Plug the detector into a standard AC outlet in areas such as bedrooms, kitchens, living rooms, or basements. Avoid placing in direct sunlight, near sources of steam or cooking fumes, or in extremely dusty environments.
A collage of images showing the HAKINAKU HD11 detector in various household settings, including a living room, bedroom, kitchen, and RV, demonstrating its versatility.

Image: Examples of suitable locations for the HAKINAKU HD11 detector, illustrating its adaptability for different rooms and environments.

4.3 Initial Power-Up

Plug the detector directly into a functional AC outlet. The device will automatically power on and begin its self-test sequence. The HD screen will illuminate, and the unit will display initial readings. The built-in battery will also begin charging.

A graphic illustrating the HAKINAKU HD11 detector's 2000mAh high-capacity battery, emphasizing its long-lasting endurance and rechargeable nature.

Image: Visual representation of the detector's internal 2000mAh backup battery, highlighting its role in providing continuous power.

5. Operating Instructions

5.1 Understanding the Display

The 2.1-inch HD screen provides real-time information:

  • CO PPM: Displays the concentration of carbon monoxide in parts per million.
  • GAS Icon: Indicates the presence of combustible gas.
  • SMOKE Bar: A visual bar or icon indicating smoke levels.
  • Temperature: Shows the ambient temperature (e.g., in °F or °C).
  • Humidity: Displays the relative humidity percentage.
  • Battery Indicator: Shows the charge level of the backup battery.
  • Speaker Icon: Indicates alarm sound status.
A close-up of the HAKINAKU HD11 detector's high-definition color screen, clearly showing CO PPM, Gas, Smoke, Temperature, and Humidity readings.

Image: Detailed view of the detector's HD screen, illustrating the various data points displayed for environmental monitoring.

5.2 Alarm Conditions

The detector will activate an audible alarm (85 dB) and visual indicators on the screen when hazardous levels of CO, smoke, or combustible gas are detected.

  • Carbon Monoxide Alarm: The CO PPM reading will increase, and an alarm will sound.
  • Smoke Alarm: The smoke indicator will activate, and an alarm will sound.
  • Combustible Gas Alarm: The GAS icon will activate, and an alarm will sound.

Upon alarm activation, evacuate the premises immediately and contact emergency services.

The HAKINAKU HD11 detector displaying a high CO reading (350 PPM) with alarm indicators, signifying a hazardous condition.

Image: The detector's screen showing an active alarm state for carbon monoxide, with a high PPM reading and visual alerts.

5.3 Testing the Unit

It is recommended to test the detector weekly to ensure proper functionality. Press and hold the test button (usually marked with a power symbol or 'Test') on the device. The alarm will sound briefly, and the display will show a test sequence. Release the button to stop the test.

6. Maintenance

6.1 Cleaning

Dust and debris can accumulate on the detector, potentially affecting its performance. Clean the exterior of the detector at least once a month using a soft, damp cloth. Do not use cleaning solvents or chemicals. Gently vacuum around the vents to remove any dust buildup.

6.2 Battery Information

The HAKINAKU HD11 features a built-in rechargeable lithium-ion battery. When the device is plugged into an AC outlet, the battery charges automatically. In the event of a power outage, the battery provides backup power for approximately 18-20 hours. A low battery indicator will appear on the screen when the battery needs recharging.

6.3 Regular Testing

Perform the self-test function (as described in Section 5.3) weekly to confirm the alarm and display are working correctly.

7. Troubleshooting

If you encounter issues with your HAKINAKU HD11 detector, refer to the following table:

ProblemPossible CauseSolution
Detector does not power onNo AC power; Battery depletedEnsure the outlet has power. If using battery, ensure it is charged.
False alarm (smoke/gas)Cooking fumes, steam, aerosols, dustVentilate the area. Relocate the detector away from sources of interference. Clean the detector.
CO alarm sounds without apparent CO sourceMalfunction; Low-level CO exposureEvacuate and ventilate. If alarm persists, contact emergency services and customer support.
Display is dim or blankLow battery; Power issueEnsure the detector is properly plugged in and charging. Allow time for battery to charge.
Test button does not workUnit malfunctionEnsure unit is powered. If issue persists, contact customer support.

If the problem persists after attempting these solutions, please contact HAKINAKU customer support.

8. Specifications

FeatureDetail
Model NumberHD11
Power SourceAC (110V-220V) with 2000mAh Lithium Ion Backup Battery
Wattage5 watts
Item Weight6.4 ounces (approx. 0.4 lbs)
Product Dimensions2.7 x 1.1 x 4.6 inches
SensorsCarbon Monoxide, Smoke, Combustible Gas, Temperature, Humidity
Alarm Loudness85 dB
Display2.1-inch HD Screen
UsageIndoor
UPC758321267083

9. Warranty and Support

9.1 Warranty Information

The HAKINAKU HD11 detector comes with a 5-Year Free Exchange Warranty for any quality issues. Please retain your proof of purchase for warranty claims.

9.2 Customer Support

For technical assistance, warranty claims, or any questions regarding your HAKINAKU HD11 detector, please refer to the contact information provided with your product packaging or visit the official HAKINAKU website. When contacting support, please have your model number (HD11) and purchase date available.

Related Documents - HD11

Preview HAKINAKU HD09 Carbon Monoxide Detector User Manual
User manual for the HAKINAKU HD09 Carbon Monoxide Detector. Learn about its features, specifications, operating instructions, and safety precautions for accurate CO monitoring.
Preview User Manual for Carbon Monoxide Detector Model D6
This user manual provides instructions and specifications for the Model D6 Carbon Monoxide Detector. Learn how to operate the device, understand CO concentration indicators, and view product specifications and safety precautions.
Preview Smart Radon Gas Detector User Manual - Model PT06/PT07 by HAKINAKU
User manual for the HAKINAKU Smart Radon Gas Detector (Model PT06/PT07). Learn about installation, operation, safety, technical specifications, and using the Tuya app to monitor radon levels in your home.
Preview Smart Indoor Air Quality Monitor User Guide - Model PT02-Plus
User guide for the PT02-Plus Smart Indoor Air Quality Monitor, detailing setup, manual settings, Tuya app integration, and smart scene creation for controlling air quality and connected devices.
Preview Gedsffati HD11-CGS Combined Smoke, Combustible Gas, and Carbon Monoxide Detector User Manual
User manual for the Gedsffati HD11-CGS, a combined smoke, combustible gas, and carbon monoxide detector. Learn about its features, functions, operation, and technical specifications.
Preview Gedsffati HD11-CG Combined Gas and Carbon Monoxide Detector User Manual