AFERIY AF-DC060

AFERIY DC600 580W Alternator Charger Instruction Manual

Model: AF-DC060

Product Overview

The AFERIY DC600 Alternator Charger is designed to efficiently charge your portable power station from your vehicle's alternator. It offers fast charging capabilities and broad compatibility, making it ideal for road trips, RVing, and other off-grid power needs.

Key Features:

What's in the Box

The AFERIY DC600 Charger package includes the following items:

AFERIY DC600 Charger and included accessories

Image: AFERIY DC600 Charger with its cables and accessories laid out.

Setup and Installation

Follow these steps to properly install your AFERIY DC600 Alternator Charger:

Step 1: Prepare for Installation

Installation accessories for AFERIY DC600

Image: All components and tools required for the installation of the AFERIY DC600 Charger.

Step 2: Connect to the Charger

  1. Plug the Anderson port of the 16.4ft DC cable into the input port of the DC600.
  2. Plug the MC4 output cable into the output port of the DC600.
  3. Use the DC/PV charging cable to connect the MC4 output cable to your power station.
Connecting cables to AFERIY DC600 Charger

Image: A person connecting the input and output cables to the AFERIY DC600 Charger.

Video: Official AFERIY DC600 Alternator Charger setup guide, demonstrating cable connections and initial power-up.

Step 3: Connect to the Car Battery

  1. Run the 16.4ft input cable through your car to the car battery.
  2. Attach the cable to the car battery terminal: red to the positive, black to the negative. Ensure the fuse cable is connected on the positive side.
Connecting AFERIY DC600 to car battery

Image: Detailed view of connecting the AFERIY DC600 input cable to a car battery, highlighting the positive and negative terminals and the fuse.

Step 4: Start Charging

  1. Turn on the DC600 charger, start the engine, and test whether the device is working properly.
  2. Find a suitable location to secure the charger within your vehicle.
AFERIY DC600 Charger in use, charging a power station in a vehicle

Image: The AFERIY DC600 Charger connected and actively charging a portable power station in the back of an SUV.

Operating Instructions

The AFERIY DC600 Charger is designed for straightforward operation. Once connected and the vehicle engine is running, it will automatically begin charging your compatible power station.

Automatic Operation:

AFERIY DC600 Smart Chips Monitor Voltage

Image: Diagram illustrating the smart chip monitoring voltage to protect the engine starting power supply, stopping charging when the engine is off or when the car battery is low.

Safety Guidelines

Your safety is paramount. Please adhere to the following guidelines when using the AFERIY DC600 Alternator Charger:

AFERIY DC600 Front-End Short-Circuit Protection

Image: Illustration of the front-end short-circuit protection design, showing how the fuse safeguards the system from wire failures.

Maintenance

To ensure the longevity and optimal performance of your AFERIY DC600 Alternator Charger, consider the following maintenance tips:

Troubleshooting

If you encounter issues with your AFERIY DC600 Alternator Charger, refer to the following common problems and solutions:

ProblemPossible CauseSolution
Charger not turning on/no output.Vehicle engine not running; incorrect wiring; blown fuse; low car battery voltage.Ensure engine is running. Check all cable connections for correct polarity and tightness. Inspect the fuse and replace if blown. Check car battery voltage; if too low, the charger may not activate to protect the battery.
Slow charging speed.Low alternator output; high resistance in cables; power station input limit.Ensure vehicle's alternator is functioning optimally. Check cable gauge and length for excessive voltage drop. Verify your power station's maximum DC input wattage.
Charger overheating.Obstructed ventilation; high ambient temperature; prolonged high-load operation.Ensure cooling vents are clear. Relocate the charger to a cooler, well-ventilated area. Reduce load if possible. The active cooling system should manage normal operating temperatures.
Charger automatically shuts down.Vehicle engine stopped; car battery voltage too low; internal protection triggered.This is normal behavior if the engine is off or car battery voltage drops below a safe threshold. If the engine is running and battery is healthy, check for other faults or consult support.

Specifications

FeatureDetail
BrandAFERIY
Model NumberAF-DC060
Input Voltage12V / 24V (Auto-sensing)
Output Power580W Max
Output Voltage48V DC (Compatible with 48V DC charging power stations)
Operating Temperature-4°F to 122°F (-20°C to 50°C)
Dimensions9.65 x 7.89 x 5.32 inches
ManufacturerShenzhen Wodefeng Technology Co., Ltd.

Warranty and Support

AFERIY provides nationwide warranty coverage for the DC600 Alternator Charger. For any assistance or inquiries, please contact our professional after-sales customer service.

Related Documents - AF-DC060

Preview AFERIY AF-DC060 580W DC-DC Charger User Manual
User manual for the AFERIY AF-DC060 580W DC-DC Charger, providing installation guidelines, safety information, technical specifications, and troubleshooting for charging portable energy storage products.
Preview AFERIY AF-DC060 580W DC-DC Charger User Manual
User manual for the AFERIY AF-DC060 580W DC-DC charger, providing detailed information on installation, operation, safety precautions, technical specifications, troubleshooting, and warranty for RV and portable energy storage systems.
Preview AFERIY AF-DC060 580W DC-DC Charger User Manual
User manual for the AFERIY AF-DC060 580W DC-DC charger, covering features, specifications, installation, usage, safety, and warranty information.
Preview AFERIY AF-PB010 Nano100 DC Portable Power Station User Manual
User manual for the AFERIY AF-PB010 Nano100 DC Portable Power Station, covering product overview, charging methods, technical specifications, and safety precautions.
Preview AFERIY AF-P310 3600W Portable Power Station User Manual
User manual for the AFERIY AF-P310 3600W Portable Power Station, detailing its features, operation, safety precautions, charging methods, display interface, troubleshooting, technical specifications, and warranty information.
Preview AFERIY AF-P010 800W Portable Power Station User Manual
Comprehensive user manual for the AFERIY AF-P010 800W Portable Power Station, detailing features, operation, safety guidelines, specifications, and troubleshooting for reliable energy storage.