Product Overview
The AFERIY DC600 Alternator Charger is designed to efficiently charge your portable power station from your vehicle's alternator. It offers fast charging capabilities and broad compatibility, making it ideal for road trips, RVing, and other off-grid power needs.
Key Features:
- 6x Faster Charging, High-Speed Output: Equipped with a 580W high-speed output for significantly shorter charging times.
- High Compatibility: Supports any power stations capable of 48V DC charging, covering 95% of models.
- Auto-Shutdown When Engine Stops: Automatically powers off when the vehicle engine stops to prevent car battery drain.
- Safety Guaranteed with Fuse Front-End Design: Ensures no devices are damaged in case of a short circuit.
- Active Cooling System: Operates stably in temperatures ranging from -4°F to 122°F.
What's in the Box
The AFERIY DC600 Charger package includes the following items:
- AFERIY DC600 Charger (DC-DC charger)
- 16.4ft DC Input Cable
- Fuse cable
- Anderson - MC4 Output Cable
- Installation accessories
- User manual

Image: AFERIY DC600 Charger with its cables and accessories laid out.
Setup and Installation
Follow these steps to properly install your AFERIY DC600 Alternator Charger:
Step 1: Prepare for Installation
- Check that all components are in place, including the 5m (16.4 ft) DC input cable.
- Gather necessary tools (e.g., screwdriver, wire strippers, multimeter).
- Have your portable power station and solar charging cable ready.

Image: All components and tools required for the installation of the AFERIY DC600 Charger.
Step 2: Connect to the Charger
- Plug the Anderson port of the 16.4ft DC cable into the input port of the DC600.
- Plug the MC4 output cable into the output port of the DC600.
- Use the DC/PV charging cable to connect the MC4 output cable to your power station.

Image: A person connecting the input and output cables to the AFERIY DC600 Charger.
Video: Official AFERIY DC600 Alternator Charger setup guide, demonstrating cable connections and initial power-up.
Step 3: Connect to the Car Battery
- Run the 16.4ft input cable through your car to the car battery.
- Attach the cable to the car battery terminal: red to the positive, black to the negative. Ensure the fuse cable is connected on the positive side.

Image: Detailed view of connecting the AFERIY DC600 input cable to a car battery, highlighting the positive and negative terminals and the fuse.
Step 4: Start Charging
- Turn on the DC600 charger, start the engine, and test whether the device is working properly.
- Find a suitable location to secure the charger within your vehicle.

Image: The AFERIY DC600 Charger connected and actively charging a portable power station in the back of an SUV.
Operating Instructions
The AFERIY DC600 Charger is designed for straightforward operation. Once connected and the vehicle engine is running, it will automatically begin charging your compatible power station.
Automatic Operation:
- The charger automatically detects when the vehicle's alternator is active and initiates charging.
- It will automatically shut down when the vehicle engine stops, preventing any drain on your car battery.

Image: Diagram illustrating the smart chip monitoring voltage to protect the engine starting power supply, stopping charging when the engine is off or when the car battery is low.
Safety Guidelines
Your safety is paramount. Please adhere to the following guidelines when using the AFERIY DC600 Alternator Charger:
- Fuse Protection: The charger incorporates a front-end fuse design to protect against short circuits, safeguarding both the charger and your vehicle's electrical system.
- Battery Protection: The auto-shutdown feature prevents excessive discharge of your vehicle's starter battery.
- Temperature Management: An active cooling system ensures stable operation across a wide temperature range (-4°F to 122°F), but ensure adequate ventilation around the unit.
- Proper Wiring: Always ensure correct polarity when connecting to the car battery (red to positive, black to negative). Incorrect wiring can cause damage.
- Secure Mounting: Securely mount the charger in a stable location to prevent movement or damage during vehicle operation.

Image: Illustration of the front-end short-circuit protection design, showing how the fuse safeguards the system from wire failures.
Maintenance
To ensure the longevity and optimal performance of your AFERIY DC600 Alternator Charger, consider the following maintenance tips:
- Regular Inspection: Periodically check all cables and connections for any signs of wear, damage, or corrosion. Ensure they are securely fastened.
- Cleanliness: Keep the charger unit clean and free from dust and debris. Use a dry, soft cloth for cleaning. Do not use liquid cleaners.
- Ventilation: Ensure the cooling vents are not obstructed to allow for proper airflow and prevent overheating.
- Storage: When not in use for extended periods, store the charger in a cool, dry place, disconnected from both the vehicle battery and the power station.
Troubleshooting
If you encounter issues with your AFERIY DC600 Alternator Charger, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Charger not turning on/no output. | Vehicle engine not running; incorrect wiring; blown fuse; low car battery voltage. | Ensure engine is running. Check all cable connections for correct polarity and tightness. Inspect the fuse and replace if blown. Check car battery voltage; if too low, the charger may not activate to protect the battery. |
| Slow charging speed. | Low alternator output; high resistance in cables; power station input limit. | Ensure vehicle's alternator is functioning optimally. Check cable gauge and length for excessive voltage drop. Verify your power station's maximum DC input wattage. |
| Charger overheating. | Obstructed ventilation; high ambient temperature; prolonged high-load operation. | Ensure cooling vents are clear. Relocate the charger to a cooler, well-ventilated area. Reduce load if possible. The active cooling system should manage normal operating temperatures. |
| Charger automatically shuts down. | Vehicle engine stopped; car battery voltage too low; internal protection triggered. | This is normal behavior if the engine is off or car battery voltage drops below a safe threshold. If the engine is running and battery is healthy, check for other faults or consult support. |
Specifications
| Feature | Detail |
|---|---|
| Brand | AFERIY |
| Model Number | AF-DC060 |
| Input Voltage | 12V / 24V (Auto-sensing) |
| Output Power | 580W Max |
| Output Voltage | 48V DC (Compatible with 48V DC charging power stations) |
| Operating Temperature | -4°F to 122°F (-20°C to 50°C) |
| Dimensions | 9.65 x 7.89 x 5.32 inches |
| Manufacturer | Shenzhen Wodefeng Technology Co., Ltd. |
Warranty and Support
AFERIY provides nationwide warranty coverage for the DC600 Alternator Charger. For any assistance or inquiries, please contact our professional after-sales customer service.
- Warranty Coverage: Enjoy nationwide warranty coverage.
- Customer Service: Reach out for assistance at any time via online customer service or the official after-sales email.